Driver Type
Categories
- Recent Updates
- Access Control
- Amplifier
- A/V Receiver
- Climate and Pool Control
- Disc Player / Changer
- Display
- DSP
- DVR
- Irrigation / Sprinklers
- Lighting Control
- Matrix Switch
- Media Server and Player
- Multi-Room A/V
- Networking
- Power and Rack Management
- Security
- Surveillance
- Teleconferencing
- Training
- Tuner
- Utility
- Video Projector
Driver Type
Categories
- Recent Updates
- Access Control
- Amplifier
- A/V Receiver
- Climate and Pool Control
- Disc Player / Changer
- Display
- DSP
- DVR
- Irrigation / Sprinklers
- Lighting Control
- Matrix Switch
- Media Server and Player
- Multi-Room A/V
- Networking
- Power and Rack Management
- Security
- Surveillance
- Teleconferencing
- Training
- Tuner
- Utility
- Video Projector
Shure P300 | IntelliMix Processor | Version 1.0
Introduction & Manufacturer Profile
Shure is a manufacturer of professional audio equipment for conferencing, live sound, and broadcast applications. The P300 IntelliMix Audio Processor is a Dante-networked automixer and DSP unit designed for conference room and huddle space installations, providing acoustic echo cancellation (AEC), automatic gain control (AGC), noise reduction, and automixing for up to 8 Dante microphone inputs.
This driver provides IP control of the Shure P300 over its TCP/IP control protocol. It supports channel mute/gain, automixer control, AEC/AGC/noise reduction per channel, preset recall, analog I/O configuration, and real-time metering.
Version History
- v1.0 - Initial Release
Driver Features
- Automixer Control - Mute, mode (Manual / Gain Share / Gating), max NOM, hold time, gate sensitivity, and last-mic lock-on for the automixer output (Ch 21)
- Channel Control - Mute and gain (0.1 dB steps) for all Dante, analog, USB, and Mobile channels
- Audio Processing - Per-channel AEC (with NLP level), AGC, and noise reduction (with level) for Dante mic inputs 1-8
- Preset Recall - Recall any of 10 device presets, with preset name feedback (all 10 names plus the current preset's name)
- Channel Names - Channel names for all 20 inputs/outputs, pulled from the P300
- Volume Scaling - Volume (0-100) sliders and variables span a configurable dB floor/ceiling (separately for inputs and outputs)
- Analog I/O Configuration - Input/output level switching (Line / Aux / Mic) and output delay
- Metering - Real-time input/output level feedback (-60 to 0 dBFS)
- Call Status - On-hook/off-hook state and control
- Auto Reconnect - Automatic reconnection on connection loss
- Background Refresh - Periodic polling to keep gate/mute state current
System Requirements & Prerequisites
Device Requirements
- Shure P300 - Firmware 4.1.x or newer
- Network - P300 control network (not the Dante audio network) reachable from the RTI processor
- IP Access - Static IP or DHCP reservation recommended on the control network interface
RTI System Requirements
- Integration Designer - 11.5 or above
- XP Processor - XP-8
- XP Firmware - 24.x or above
Driver Configuration
- In Integration Designer, add the Shure P300 driver to your project
- Enter the IP Address of the P300's control network interface (default:
192.168.1.100) - Set the IP Port (default:
2202) - Optionally, set Volume Scaling (see below)
- The driver connects automatically and begins its initialization sequence on program load
Volume Scaling
These settings control what 0% and 100% mean for every Volume (0-100) function and variable, plus how far Volume Up/Down can move. The defaults cover the full device range (-110 to +30 dB), so if you leave them alone nothing changes.
- Input Volume Floor / Ceiling (dB) - Range for inputs (Dante Mic 1-8, Dante 9-10, Analog, USB, Mobile)
- Output Volume Floor / Ceiling (dB) - Range for outputs (Dante, Analog, USB, Mobile outputs)
- Volume Up/Down Step (0.1 dB units) - Size of each Up/Down step (default 10 = 1 dB)
Example: with Input Floor -60 and Input Ceiling 0, a mic's Volume (0-100) of 0% sends raw 500, 50% sends raw 800, and 100% sends raw 1100. Up/Down stops at those limits too. Volume (Native) still accepts the full 0-1400 range. If a channel is set outside the window some other way, its Volume (0-100) shows 0 or 100.
Device dB to raw: raw = (dB + 110) x 10. If you enter a floor that is not below the ceiling, the driver falls back to the full range.
Note: Use the P300's control network address, not its Dante (audio) network address. These are separate interfaces on the device.
Functions
Preset Control
- Recall Preset - Recall preset 1-10
Automixer Mute - System Mute
- Automixer Mute - Mute/unmute the automixer output (recommended method for system muting)
- System Mute - Alias for Automixer Mute (identical effect, provided as an alternate name for panel/macro convenience)
Device Audio Mute
- Device Audio Mute - Mute/unmute the entire device
Per-Channel Mute / Gain
Every controllable channel (01-08, 09-10, 11-12, 13, 14, 15-16, 17-18, 19, 20) has its own dedicated category with:
- [Channel] Mute - On/Off/Toggle, e.g.
Dante Mic Input 1 Mute,Analog Output 1 Mute,USB Input Mute - [Channel] Volume (Native) - Set gain directly, range 0-1400
- [Channel] Volume (0-100) - Set gain as a 0-100 scale across the configured Volume Scaling floor/ceiling (full 0-1400 by default). Slider-capable
- [Channel] Volume Up/Down - Step gain up/down by the configured Volume Up/Down Step (default 1 dB), limited to the Volume Scaling floor/ceiling (repeatable) - available on all 20 channels
Note: There's no generic "pick a channel from a dropdown" mute/gain function - each channel is a dedicated single-purpose function. This is deliberate: a function with a channel-picker parameter in front of Gain can't render as a slider in Integration Designer, and per-channel functions are required for autoprogram/manual button linking anyway (we can't disambiguate 20 channels through one shared function).
Audio Processing (AEC / AGC / Noise Reduction, Dante mic inputs 1-8)
- Set AEC - On/Off/Toggle
- Set AEC NLP Level - Low / Medium / High
- Set AEC Reference - Assign the AEC reference source (Ch 22)
- Set AGC - On/Off/Toggle
- Set Noise Reduction - On/Off
- Set Noise Reduction Level - Low / Medium / High
Automixer Settings (Ch 21)
- Set Automixer Mode - Manual / Gain Share / Gating
- Set Automixer Max NOM - 1-8
- Set Automixer Last Mic Lock On - On/Off/Toggle
- Set Automixer Hold Time - 100-1500 ms
- Set Automixer Gate Sensitivity - 1-9
- Set Automixer Channel Always On / Set Automixer Channel Priority - Per-channel automixer flags
- Set Compressor - On/Off/Toggle (Ch 00 or 21)
Analog I/O Level
- Set Analog Input Level - Line / Aux
- Set Analog Output Level - Line / Aux / Mic
Output Delay
- Set Delay - 0-1000 ms
LED and Flash
- Set LED Brightness - Disabled / Dim / Default
- Flash P300 - Flash LEDs for identification (auto-off after 30 sec)
Metering
- Metering is off by default - the device reports null for all five meter types until you explicitly enable it. Call the matching Set Meter Rate function below with a non-zero value (e.g. 1000 ms) to start receiving live level updates for that meter type; without doing so, the
Meter - [Channel]variables stay null indefinitely. - Set Input/Output/Processing/ERLE/AGC Meter Rate - 0 (off) or 100-99999 ms. There is no valid value between 1-99 (that range doesn't exist on the device) - submitting one is treated as "on" and snapped up to 100 (the fastest valid rate), not silently turned off. Submit exactly
0to disable periodic meter reporting for that meter type. - Set Input/Output Meter Mode - Pre-Fader / Post-Fader
Call Status
- Set Onhook Enable - Enable/Disable
Direct Output
- Set Direct Out Tap Point - Pre-Gate/Pre-Processing, Pre-Gate/Post-Processing, Post-Gate/Pre-Processing, Post-Gate/Post-Processing
Device Management
- Reboot P300
- Restore Default Settings
- Send Raw Command - Send any ASCII command for anything not exposed above, including commands added in newer firmware. The
< >brackets are optional:GET 21 AUTOMXR_MUTEand< GET 21 AUTOMXR_MUTE >both work. The reply shows in the Last Response variable
Channel Map
- 00 - All Channels (where supported)
- 01-08 - Dante Mic Inputs 1-8
- 09-10 - Dante Inputs 9-10
- 11-12 - Analog Inputs 1-2
- 13 - USB Input
- 14 - Mobile Input
- 15-16 - Dante Outputs 1-2
- 17-18 - Analog Outputs 1-2
- 19 - USB Output
- 20 - Mobile Output
- 21 - Automixer Output (primary system mute/mode/gate; no gain parameter)
- 22 - AEC Reference
Function to Variable Quick Reference
Function and variable names match 1:1 throughout this driver (e.g. the function Dante Mic Input 1 Volume (Native) feeds the variable of the same name) - see the Functions and Variables sections above for the full per-category breakdown. This section only calls out the pairings that aren't obvious from the name alone:
- Mute functions also produce
MutedandUnmutedboolean twins (not just the plain 0/1 variable) - bind button highlighting to those, not the integer. - Bind sliders to Volume (0-100), not Volume (Native) - see the note under Per-Channel State below for why.
- Volume Up/Down has no variables of its own - it just nudges the same Volume (Native)/Volume (0-100) feedback.
- Recall Preset feeds three variables per slot, not one:
Current Preset,Preset N Name, andPreset N Active. - Meter Rate and Direct Out Tap Point functions do have device readback (confirmed via live traffic) - this was wrongly assumed to be action-only in an earlier pass, corrected here.
- Reboot and Restore Default Settings are genuinely action-only - no variables at all.
- Send Raw Command has no dedicated feedback, but its reply (like every other non-meter device message) lands in
Last Responseunder Device Management. - System Mute has no dedicated variable of its own - it's a plain alias for Automixer Mute, so read
Automixer Mute/Automixer Muted/Automixer Unmutedinstead.
Variables
Variable categories mirror the function categories above 1:1 by name, so a category found in the function tree has a same-named counterpart in the variable tree (and vice versa, for anything with feedback). The two extra categories below (Connection Status, Device Info) have no function equivalent - they're pure device/driver state.
Connection Status
- Connection State (Integer) - 0 = Disconnected, 1 = Connected
- Initialization State (Integer) - 0 = Ready, 1 = Initializing
Device Info
- Model, Serial Number, Firmware Version, MAC Address, Encryption
- USB Connected / USB Connect State
Preset Control
- Current Preset (1-10), Current Preset Name, Preset N Name (N = 1-10), Preset N Active (N = 1-10)
- Names are read from the P300 on connect and update when a preset is renamed
Device Settings
- Device Audio Mute / Muted / Unmuted, LED Brightness, Flash
Device Management
- Last Response (string) - The most recent message from the device (meter samples excluded), e.g.
< REP 01 CHAN_NAME {Podium Mic} >. Use it to see replies to Send Raw Command
Call Status
- Call Status Enabled, Call State (On Hook / Off Hook)
Automixer Settings (Ch 21)
- Automixer Mute / Muted / Unmuted, Automixer Mode, Automixer Max NOM, Automixer Hold Time, Automixer Gate Sensitivity, Automixer Off Attenuation, Automixer Last Mic Lock On, Compressor (Ch 21 has no gain parameter)
Audio Processing
- [Dante Mic Input N] AEC / AEC On / AEC NLP Level - N = 1-8
- [Dante Mic Input N] AGC / AGC On - N = 1-8
- [Dante Mic Input N] Noise Reduction / Noise Reduction On / Noise Reduction Level - N = 1-8
- AEC Reference (Ch 22)
Analog I/O Level
- Analog Input 1/2 Level Switch, Analog Output 1/2 Level Switch
Output Delay
- Analog Output 1/2 Delay, USB Output Delay
Metering
- Input/Output Meter Mode
- Meter - [Channel] - one per channel, all 20 channels (0-60, mapped to -60 to 0 dBFS)
Per-Channel State
Every controllable channel has its own dedicated variable category (matching its function category name) with:
- [Channel] Name (string) - The channel name set on the P300 (e.g. "Podium Mic"), read on connect
- [Channel] Mute (integer) / [Channel] Muted / [Channel] Unmuted (booleans)
- [Channel] Volume (Native) (integer, 0-1400) - precision reference/numeric-entry only - do not bind a slider to this, see note below
- [Channel] Volume (0-100) (integer, 0-100) - percentage of the configured Volume Scaling range, kept in sync automatically - bind sliders and % text to this one
- [Channel] Gate Status (integer) / Gate Open / Gate Closed (booleans) - Dante Mic Input 1-8 only
Categories: Dante Mic Input 1-8, Dante Input 9/10, Analog Input 1/2, USB Input, Mobile Input, Dante Output 1/2, Analog Output 1/2, USB Output, Mobile Output.
- Mute-style (2-state): Mute/Muted/Unmuted (all 21 channels incl. Ch21 raw), Encryption, Flash, Call Status Enabled, Automixer Last Mic Lock On, Compressor, AEC/AGC/Noise Reduction On/Off (per Dante mic input), Automixer Gate Open/Closed (per Dante mic input)
Events
Connection
- CONNECTIONSTATE, CONNECTIONSTATE00 (Disconnected), CONNECTIONSTATE01 (Connected), INITIALIZATIONSTATE
Automixer
- AUTOMXRMUTE, AUTOMXRMUTE_21, AUTOMXRGATE
Channel Mute
- AUDIOMUTE_NN - fired per channel on mute state change (NN = 01-21)
Device / Call
- DEVICEAUDIOMUTE, ONHOOKSTATE, PRESET
Metering
- METERIN, METEROUT, METERPROC, METERERLE, METERAGC
Autoprogramming Support
What's tagged (and why these two specifically)
- Automixer Mute (Ch 21) - the one genuinely single, non-repeated mute control in the driver, used exactly once, not spread across channels.
- Recall Preset (1-10) - the Master Tag List has numbered variants (
Preset 1through at leastPreset 56) specifically for this - the only place in the vocabulary that supports per-instance numbering.
Exact tag assignments:
Mute/Mute On/Mute Off- Automixer Mute's Toggle/On/Off choicesMute, Mute On/Mute Off-Automixer Muted/Automixer Unmutedvariables (LED feedback)Preset-Current PresetvariablePreset 1-Preset 10- Recall Preset's 10 choices, and the matchingPreset N Activevariables (LED feedback for whichever preset is currently active)
Limitations
- The driver connects to the P300's control network interface, not the Dante audio network - use the control IP address in configuration
- AEC, AGC, and noise reduction control are only exposed for Dante mic inputs 1-8, matching the P300's automixer channel layout
- Initialization is staged (one group of GET queries every 500 ms) to avoid flooding the device on connect; full state feedback may take several seconds after connection
- Metering is off by default and must be explicitly enabled via Set Meter Rate (see Functions > Metering) - once enabled, it runs continuously at whatever rate was set for the life of the connection, which is ongoing background network traffic, not a one-time query
Support Contact
AVPro Global - Remote Technologies Inc.
Phone: +1 952-253-3100
Email: support@avproglobal.com