This driver provides IP control over the Elk Products E27 security panel. It enables area arming/disarming, zone status monitoring, and alarm event triggering through the Elk Dealer API over a standard TCP connection.
 
**This driver does not currently support Z-Wave peripheral devices. This driver is only for control of the E27 panel itself**
 

Version History

 - Version 1.0: Initial Release

Introduction

This driver provides IP control over the Elk Products E27 security panel. It enables area arming/disarming, zone status monitoring, and alarm event triggering through the Elk Dealer API over a standard TCP connection.

Version History

  • Version 1.0: Initial Release

Driver Features

  • Area Control: Arm/disarm up to 8 areas (DISARMED, ARMEDSTAY, ARMEDAWAY), requires a PIN entered on a keypad
  • Alarm Events: Trigger FIRE, MEDICAL, or PANIC, uses the panel's configured PIN automatically, no code entry required
  • Zone Monitoring: Real-time status for all configured zones (Normal, Trouble, Violated, Bypassed)
  • Zone Bypass: Bypass/unbypass individual zones, requires a PIN entered on a keypad
  • Auto-Reconnect: Automatic reconnection with heartbeat monitoring
  • Real-time Push: Receives unsolicited status updates from the panel

System Requirements

RTI System Requirements

  • Integration Designer: 11.6 or higher
  • Minimum Apex Version: 11.600
  • Minimum Runtime Version: 24
  • Minimum Software Version: 10.000
  • Processor: XP-8

Elk Panel Requirements

  • Dealer API: Must be enabled on the panel
  • Network: Panel must have an IP module connected and reachable
  • PIN: A valid 4-digit PIN with appropriate permissions

About the PIN

There are two distinct PINs in play, and they are not interchangeable:

  • Driver-configured PIN (entered in driver properties during setup): used only to authenticate the panel connection and to run Sync. It is also used automatically for Fire/Medical/Panic alarm triggers, since those are emergency actions with no user code entry, the same as pressing a physical duress button.
  • Remote-entered PIN (entered by the user on a virtual keypad at the time of the command): required for every Arm/Disarm and every Zone Bypass/Unbypass command. These are keypad-only actions; there is no direct "type a PIN into a text box" shortcut, and they do not fall back to the driver-configured PIN. Without a full 4-digit PIN entered on a keypad, the command never gets sent.

Driver Configuration

  1. Import Driver: Add Elk E27.rtidriver to your Integration Designer project.

  2. Run Discovery Script: In Integration Designer, use "Discover Elk Panels" to do an mDNS scan and detect the IP of any panels.

  3. Set Connection Parameters:

    • Enter the panel's IP address
    • Enter the 4-digit PIN
  4. Run Sync Script: In Integration Designer, use "Sync with Panel" to connect to the device IP you entered. This should pull applicable information from the panel.

  5. Verify: After the driver loads, check that zone and area system variables are populating correctly in the driver monitor.

System Variables

Connection

  • Connected (Boolean): True when authenticated to the panel
  • Disconnected (Boolean): True when not connected
  • ConnectionState (Integer): 0 = disconnected, 1 = authenticated

Area Variables

One set of variables is created per area (replace N with the area number, e.g. ArmState_1):

  • ArmState_N (Integer): Current arm state, 0=Disarmed, 1=Armed Stay, 2=Armed Away, 3=Alarm Memory
  • ArmState0_N (Boolean): True when area N is Disarmed
  • ArmState1_N (Boolean): True when area N is Armed Stay
  • ArmState2_N (Boolean): True when area N is Armed Away
  • ArmState3_N (Boolean): True when area N is in Alarm Memory
  • AlarmActive_N (Boolean): True when an alarm is active in area N
  • Ready_N (Boolean): True when area N is ready to arm

Zone Variables

One set of variables is created per zone (replace N with the zone number, e.g. ZoneStatus_3):

  • ZoneStatus_N (Integer): Current zone status, 0=Normal, 1=Trouble, 2=Violated, 3=Bypassed
  • ZoneStatus0_N (Boolean): True when zone N is Normal
  • ZoneStatus1_N (Boolean): True when zone N is in Trouble
  • ZoneStatus2_N (Boolean): True when zone N is Violated
  • ZoneStatus3_N (Boolean): True when zone N is Bypassed

Keypad Variables

One set of variables is created per keypad discovered during sync:

  • KeypadName_N (String): Name of keypad N as configured on the panel
  • KeypadCodeActive_N (Boolean): True while keypad N is waiting for a PIN to be typed on its virtual keypad. Use this to show/hide the on-screen numeric pad.
  • KeypadCodeDisplay_N (String): Masked (*) representation of the digits entered so far on keypad N's virtual keypad

System Functions

Required Order: Choose the Command, Then Enter the PIN

Arm/Disarm and Bypass are two-step, in a fixed order, by design. Trigger Alarm is the one exception (see below).

  1. Press the command button first: Area's Arm/Disarm (pick Mode + Keypad) or Zone's Bypass (pick Keypad). This only stages the command locally; nothing is sent to the panel yet.
  2. Then press that same keypad's Numeric Key four times (the PIN digits). The 4th digit press is what actually sends the command to the panel.

This order is intentional, not just a technical requirement. Staging the command first, before asking for a PIN, gives the user a chance to catch a wrong choice (wrong mode, wrong zone) before committing to entering a code. If the wrong command got staged, press Cancel Code Entry to back out before typing any digits, instead of entering a PIN against the wrong command.

If Numeric Key is pressed with nothing staged (step 1 skipped), it does not just fail: it falls back to a toggle of that keypad's own area (Disarmed arms Away, anything else disarms), which may not be the mode intended. Always wire the command button before the numeric pad.

Trigger Alarm is the one exception to this order: Fire/Medical/Panic fire immediately with no PIN and no keypad involved at all, exactly like a physical duress button. Never wire it through a keypad's Numeric Key; doing so would only slow down an emergency trigger for no reason.

Area Control

  • Arm/Disarm (areaid, mode, keypadid): Stages an arm/disarm command for this area and waits for a 4-digit PIN entered via the chosen keypad's Numeric Key function. Area bakes in automatically (generated once per area); the only thing to pick is which keypad's on-screen PIN pad should collect the code. Only keypads actually assigned to this area are offered, matching the physical panel.
  • Trigger Alarm (areaid, alarmevent): Trigger FIRE, MEDICAL, or PANIC. Uses the driver-configured PIN automatically, no code entry required, same as a physical duress button. Not keypad-gated: an emergency trigger must never require a PIN.

Valid alarm_event values: FIRE, MEDICAL, PANIC

Zone Control

  • Bypass (zoneid, bypassed, keypadid): Stages a zone bypass/unbypass and waits for a 4-digit PIN entered via the chosen keypad's Numeric Key function. Zone bakes in automatically (generated once per zone); the only thing to pick is which keypad's on-screen PIN pad should collect the code.

Keypad Control

One set of functions is created per keypad discovered during sync:

  • Key Press (keypad_id, key): Send a raw keypress (e.g. a function key) straight to the specified keypad. No PIN involved.
  • Numeric Key (Digit 0-9): Appends a digit to this keypad's PIN buffer. Submits automatically once 4 digits have been entered, completing whichever command (an area's Arm/Disarm or a zone's Bypass) was last staged on this keypad. If pressed with nothing staged, it toggles this keypad's own area instead (see above).
  • Cancel Code Entry: Clears the pending command and PIN buffer immediately, without submitting anything to the panel.

Together, these three functions are the only way this driver arms, disarms, or bypasses. There is no direct "type a PIN into a text box" shortcut for any of them, matching the Elk M1 driver's on-screen PIN pad behavior.

Troubleshooting

Panel not connecting

  • Verify the IP address is correct and the panel is reachable on the network
  • Confirm the Dealer API is enabled in the panel's configuration
  • Check that port 2101 is not blocked by a firewall

Authentication failing (error_code ≠ 0)

  • Verify the PIN is correct and has permission to connect via the Dealer API
  • The driver uses a 4-digit numeric PIN only. No access codes or passphrases.

Variables not populating

  • Run scripts from Integration Designer to sync area and zone counts from the panel
  • Confirm areaCount and zoneCount in driver properties are non-zero
  • Check driver monitor logs for parse errors

Driver stops polling after disconnect

  • The driver's heartbeat will detect a dead connection within 2 poll cycles and reconnect automatically
  • If reconnection is not happening, check that the panel IP address is still reachable