- Recent Updates
- Access Control
- Amplifier
- A/V Receiver
- Climate and Pool Control
- Disc Player / Changer
- Display
- DSP
- DVR
- Irrigation / Sprinklers
- Lighting Control
- Matrix Switch
- Media Server and Player
- Multi-Room A/V
- Networking
- Power and Rack Management
- Security
- Surveillance
- Teleconferencing
- Training
- Tuner
- Utility
- Video Projector
- Recent Updates
- Access Control
- Amplifier
- A/V Receiver
- Climate and Pool Control
- Disc Player / Changer
- Display
- DSP
- DVR
- Irrigation / Sprinklers
- Lighting Control
- Matrix Switch
- Media Server and Player
- Multi-Room A/V
- Networking
- Power and Rack Management
- Security
- Surveillance
- Teleconferencing
- Training
- Tuner
- Utility
- Video Projector
Operating in the Home & Building and Access Activities, Dooya is the leading Chinese brand in tubular motors, particularly at the entry-level. Dooya specializes in the design of control systems for rolling shutters, rolling doors, curtains and interior blinds.
Dooya is part of the Somfy Group’s portfolio of complimentary brands. Together, they cover most automation needs for openings and closures of homes and buildings around the world. They also allow the Group to service its distribution channels—manufacturers, installers, DIY superstores, e-commerce, architects—with suitable solutions.
Overview
Operating in the Home & Building and Access Activities, Dooya is the leading Chinese brand in tubular motors, particularly at the entry-level. Dooya specializes in the design of control systems for rolling shutters, rolling doors, curtains and interior blinds.
Dooya is part of the Somfy Group’s portfolio of complimentary brands. Together, they cover most automation needs for openings and closures of homes and buildings around the world. They also allow the Group to service its distribution channels—manufacturers, installers, DIY superstores, e-commerce, architects—with suitable solutions.
System Functions
Sysem Commands
Get Devices
This command is run at startup and attaches the input mac addresses entered in the config. This can be run later to discover mac addresses if required.
Device 1-50 Name Commands
Send Close [TAG: Shade Down: 1-50]
The Send Close command allows you to close the blind from a fully or partially opened state.
Send Open [TAG: Shade Up: 1-50]
The Send Open command allows you to open the blind from either a closed state or further open from a partially opened state.
Send Stop [TAG: Shade Stop: 1-50]
The Send Stop command allows you to stop the current open or close action before it has completed its action.
Set Position [TAG: Shade Level: 1-50]
Only available from two-way devices, the Set Position command allows you to open or close the blind from it's current position to the specified position. This also allows adjustment from a slider control.
Set Tilt [TAG: Angle: 1-50]
Only available from tilt enabled devices, the Set Tilt command allows you to adjust the position of the tilt from 0 degrees to 180 degrees. This command becomes available once the blind is in the closed position which can be around 90% to which the angle will use the last 10% of the position for the angle.
Closing the blind to 100% will also fully tilt the blind to 180 degrees.
System Variables
Variables are only available on two-way controlled devices
Device 1-50 Name
Blind Position [integer] [TAG: Level]
The Blind Position variable displays the current position of the blind, this is a percentage amount where 0 is fully open and 100 is fully closed.
Blind Open [boolean] [TAG: Open]
The Blind Open variable displays as true when the blind is partially or fully open.
Blind Closed [boolean] [TAG: Closed]
The Blind Closed variable displays as true when the blind is fully closed.
Blind Top Position [integer] [TAG: Top Level]
The Blind Top Position variable displays the current position of the top portion of the blind, this is a percentage amount where 100 is fully closed and 0 is fully open. Note that the top position cannot be greater then the bottom blind position.
Blind Top Open [boolean] [TAG: Top Open]
The Blind Top Open variable displays as true when the top portion of the blind is partially or fully open, this is a position greater than 0.
Blind Top Closed [boolean] [TAG: Top Closed]
The Blind Top Closed variable displays as true when the top portion of the blind is fully closed, this is when the position is equal to 0.
Blind Bottom Position [integer] [TAG: Bottom Level]
The Blind Top Position variable displays the current position of the top portion of the blind, this is a percentage amount where 0 is fully closed and 100 is fully open. Note that the bottom position cannot be lesser then the top blind position.
Blind Bottom Open [boolean] [TAG: Bottom Open]
The Blind Bottom Open variable displays as true when the bottom portion of the blind is partially or fully open, this is when the position is less than 100.
Blind Bottom Closed [boolean] [TAG: Bottom Closed]
The Blind Bottom Closed variable displays as true when the bottom portion of the blind is fully closed, this is when the position is equal to 100.
Tilt Position [integer] [TAG: Tilt]
The Tilt Position variable displays the position of the current tilt as a value between 0 and 180, where 180 is closed and less than is open.
For the Tilt to be at 180 the position of the blind must be 100%
Battery Level [integer] [TAG: Battery]
The Battery Level variable displays the amount of charge remaining in a two-way blind fitted with battery. This value is shown in mAh and can vary from device to device.
If there are multiple batteries / reported levels on a device the lowest is displayed.
Signal Strength [integer] [TAG: Signal]
The Signal Strength variable displays the received signal strength indicator by the bridge to the blind device. The higher the number the better the signal, For example the value of -30 being a good connection and the value of -60 being a poor connection.
System Events
Events are only available on two-way controlled devices
Device 1-50 Name
Blind Open
The Blind Open event is sent when the blind transitions from a closed state to an open one. If the blind is stopped and further opened this will not send again.
For top down bottom up devices the blind is open if either the top or the bottom blind is not fully closed.
Blind Closed
The Blind Closed event is sent when the blind transitions from an open state to closed.
For top down bottom up devices the blind is closed only when the top and the bottom blind are both fully closed.
Battery Low
The Battery Low event is sent when the device reports less than 100 mAh
For devices with multiple batteries this event is sent when the lowest device reports less than 100 mAh