Driver Details

New

Bond Bridge

By: RTI
Updated: Aug. 21, 2026
Version: 1.0
Download Driver
Rating: 0.0 (0 ratings)
Log in to rate this driver
The Bond Bridge driver provides monitoring and control of devices supported by Bond Bridge and Smart by Bond, over a standard HTTP network connection. The driver communicates using the Bond Local REST API and discovers configured devices, groups, and scenes. During driver configuration, it dynamically generates Sources, Functions, Variables, and Events based on the capabilities supported by each discovered device.
 

Version History

v1.0 - Initial release

Bond Bridge | HTTP | Version 1.0

Introduction

The Bond Bridge driver provides monitoring and control of devices supported by Bond Bridge and Smart by Bond, over a standard HTTP network connection. The driver communicates using the Bond Local REST API and discovers configured devices, groups, and scenes. During driver configuration, it dynamically generates Sources, Functions, Variables, and Events based on the capabilities supported by each discovered device.


Driver Supports

  • Single/Multi Bond Bridge Control
  • Ceiling Fan Control
  • Light Control
  • Motorized Shade Control
  • Fireplace Control
  • Heater Control
  • Group Control
  • Scene Trigger

Version History

  • Version - 1.0 (Initial Release)

Driver Features

The driver builds RTI Sources, Functions, Variables, and Events from each discovered device's capabilities, so the available controls depend on what each device supports.

Ceiling Fan Control

  • Power ON/OFF/Toggle
  • Speed
  • Direction Control (Forward/Reverse)
  • Toggle Direction
  • Breeze Mode
  • Timer
  • Brightness Control
  • UpLight Brightness
  • DownLight Brightness

Light Control

  • Light ON/Off/Toggle
  • Brightness
  • Color Temperature
  • HSV Color (Supported Devices)

Shade Control

  • Open
  • Close
  • Hold (Stop)
  • Position
  • Extend
  • Retract
  • Tilt
  • Toggle Tilt
  • Upper Rail Position
  • Lower Rail Position
  • Blackout Position
  • Sheer Position

Fireplace Control

  • Flame (Increase/Decrease)
  • Flame Adjust
  • Fan (On/Off/Toggle)
  • Fan Speed Adjust

Heater Control

  • Heat Control (Increase/Decrease)
  • Heat Level Adjust

Group Control

  • Group Selection
  • Group Action Selection
  • Group Action Value Selection (speed, brightness, position, etc.)
  • Refresh Groups

Scene Control

  • Refresh Scenes
  • Trigger Scene

Advanced

  • Raw Command — execute any Bond Local API request (for reference https://docs-local.appbond.com/)
  • BPUP (UDP) push events for real-time device state updates

Driver Variables

Based on the device capabilities, the following variables are exposed:

  • Power On
  • Power Status
  • Power Off
  • Speed
  • Breeze Mode (breeze mode disabled, breeze mode enabled)
  • Breeze On
  • Breeze Off
  • Breeze Mean
  • Breeze Variance
  • Direction Status (Forward/Reverse)
  • Light Status (Light Off/Light On)
  • Light On
  • Light Off
  • UpLight Status (UpLight Off,UpLight On)
  • UpLight On
  • UpLight Off
  • DownLight Status (DownLight Off,DownLight On)
  • DownLight On
  • DownLight Off
  • Light Brightness
  • UpLight Brightness
  • DownLight Brightness
  • Color Temperature
  • Light Color Hue
  • Light Color Saturation
  • Light ColorSpace(value)
  • Current Flame Level
  • Heat Level
  • Shade Status (Closed, Open)
  • Shade Open
  • Shade Close
  • Shade Position
  • Shade Upper Rail Position
  • Shade Lower Rail Position
  • Shade Tilt Position
  • Shade Blackout Position
  • Shade Sheer Position
  • Fireplace Fan Status (Off, On)
  • Fireplace Fan On
  • Fireplace Fan Off
  • Fireplace Fan Speed
  • Battery
  • Supply Voltage
  • Supply Power
  • Signal Strength

Driver Events

For supported devices:

  • Power On
  • Power Off
  • Light On
  • Light Off
  • Shade Open
  • Shade Close
  • Breeze Mode On
  • Breeze Mode Off
  • Fireplace Fan On
  • Fireplace Fan Off
  • Up Light On
  • Up Light Off
  • Down Light On
  • Down Light Off

Global

  • Message

System Requirements

  • RTI Integration Designer 11.x or above
  • RTI XP Processor Firmware 25.x or above
  • Bond Bridge and RTI Processor must be connected to the same local network.
  • Bond Bridge must be reachable over HTTP.

Driver Configuration

1. Prepare Bond Bridge

  • Verify the Bond Bridge is installed and powered on.
  • Verify all the devices were paired to the respective Bond Bridge.
  • Connect the Bond Bridge to the local network.
  • Obtain the IP Address of each Bond Bridge.

2. Configure Driver Settings

  • Enter Driver Name.
  • Enter the number of Bond Bridges. *Required
  • Enter the IP Address for each Bond Bridge. *Required
  • Enter the Pin for each Bond Bridge. *Required
  • Configure Debug Level if required.

3. Run the Configuration Script

  • Click Get Device Data.

The driver automatically discovers:

  • Devices
  • Device Capabilities

Configuration settings are automatically generated based on the discovered devices and supported capabilities.


4. Build Driver

  • Click Build Driver.

The driver automatically generates:

  1. Sources
  2. Functions
  3. Variables
  4. Events

5. Add Sources

After the configuration process completes, the following sources become available for each discovered device.

  • {Device Name} - Device Source

Each discovered device is automatically created as an RTI Source.


Autoprogram

  • After adding sources, use RTI Autoprogram to automatically map functions and variables to supported RTI templates.

Note

  • Devices are discovered automatically from all configured Bond Bridges.
  • Functions are generated only for capabilities supported by each device.
  • Groups and Scenes are discovered dynamically.
  • Assign static IPs to all configured Bond Bridges.
  • Verify devices were paired to the respective Bond Bridge before running the configuration script.
  • Variables, Events, and Functions are generated based on the device’s reported capabilities. For further details, please refer to the Bond Bridge documentation.

Limitations

  • Bond Bridge must be reachable on the local network.
  • Only capabilities supported by the Bond Local API are exposed within RTI.

System Testing

RTI Platform

  • Integration Designer: 11 or above
  • XP Processor Model: XP-3
  • XP Processor Firmware: 26.6.1

Bond Bridge Devices Tested

  • Bond Bridge Pro : BD-1750-PRO
  • Bond Bridge : BD-1000

Support Contact

Miantic AV Distribution Pvt. Ltd. licenses@miantic.com Copyright © Miantic AV Distribution 2021–2026

Please log in to leave a comment.