Driver Type
Categories
- Recent Updates
- Access Control
- Amplifier
- A/V Receiver
- Climate and Pool Control
- Disc Player / Changer
- Display
- DSP
- DVR
- Irrigation / Sprinklers
- Lighting Control
- Matrix Switch
- Media Server and Player
- Multi-Room A/V
- Networking
- Power and Rack Management
- Security
- Surveillance
- Teleconferencing
- Training
- Tuner
- Utility
- Video Projector
Driver Type
Categories
- Recent Updates
- Access Control
- Amplifier
- A/V Receiver
- Climate and Pool Control
- Disc Player / Changer
- Display
- DSP
- DVR
- Irrigation / Sprinklers
- Lighting Control
- Matrix Switch
- Media Server and Player
- Multi-Room A/V
- Networking
- Power and Rack Management
- Security
- Surveillance
- Teleconferencing
- Training
- Tuner
- Utility
- Video Projector
Provides two way control via TCP/IP (telnet), over AudioControl RS Series devices. Features zone power, volume control, preset recall, and more.
Version History
v1.0 - Initial Release
AUDIOCONTROL|RS SERIES|IP|1.00
Installer Setup Guide
This is the simplified embedded version of the instructions for this driver. A fully-formatted version of these instructions is available in Instructions.pdf under Additional Files.
Part 1 - Getting Started
About the Driver
The AudioControl RS Series driver has been developed by Janus Technology for controlling the AudioControl RS500 and RS1000 DSP subwoofer amplifiers over TCP/IP. One driver handles both models - you choose the exact model as a configuration setting.
Driver Features
• Two-way control via TCP/IP (telnet), with a configurable control port
• Zone power and global (main supply) power, with feedback and events
• Volume control with press-and-hold ramping, plus mute
• Bass level control
• Recall of the amplifier's six EQ presets, with the current preset name as feedback
• Signal sense (auto on/standby) on/off
• Lip sync delay up/down
• Health monitoring: temperature, voltage, protection, thermal protection and short circuit, with a single Fault flag and events
• Device information: amplifier name, model and firmware version
• Raw API command pass-through for diagnostics
System Requirements & Prerequisites
• Integration Designer: Version 11 or later
• RTI Processor: XP family, minimum software version 9.9, minimum Apex version 10.8, minimum runtime version 20
• Amplifier: AudioControl RS500 or RS1000. Tested on firmware v2.0.47
• Network: The amplifier's control port (23 by default) reachable from the RTI processor
• Device configuration: Amplifier set up and tested using AudioControl's own web interface before adding the RTI driver
Before You Start
Complete these checks before opening the driver configuration. This driver does not discover the amplifier automatically - there is no "Query" action. Everything below is a manual, one-time setup step.
Network Requirements
• The amplifier must already have an IP address. A static address or DHCP reservation is strongly recommended.
• The amplifier and RTI processor must be reachable across the network.
• Record the amplifier's IP address and its control port before you begin. Both are shown in the amplifier's web interface.
Amplifier Preparation
• Set up the amplifier with AudioControl's web interface first: amplifier name, EQ presets, signal sense timeout and lip sync.
• Name and save the EQ presets you want the end user to recall. The driver recalls presets 1 to 6 and shows the name saved on the amplifier.
• Check the amplifier's firmware version against the requirements above.
Part 2 - Commissioning
Add the Driver to Integration Designer
This section establishes the driver and its connection settings before any project-specific UI programming is attempted.
From Add Workspace Item -> Drivers, choose the AudioControl RS Series driver from the Official list.
Open the driver's Config Settings page.
Save the project before continuing.
Choose the Model
Set the Model setting to the amplifier you are commissioning: RS500 or RS1000.
Connection Settings
• Model: RS500
• Model: The amplifier model: RS500 or RS1000.
• IP Address: 192.168.1.101
• IP Address: The amplifier's IP address.
• Control Port: 23
• Control Port: The amplifier's control (telnet) port, as set in its web interface.
• Poll Interval: 10
• Poll Interval: Seconds between status requests, from 5 to 1800 (30 minutes). A lower value is treated as 5 and a higher one as 1800. Changes made at the amplifier or from its web interface show in RTI within this time.
Prove Basic Control
Before building the full user interface, prove one simple command. This validates the connection and basic feedback before anything else is built on top of it.
Create a test button and assign the Volume Up function (tag Volume Up).
Bind a label to the Volume variable and an indicator to Connection Status.
Download/run the project and press the button once. The volume should go up by one and the label should update.
Part 3 - Common Programming Tasks
Power
The amplifier has two separate power controls:
• Power switches the amplifier zone on and off. This is the normal on/off for the end user.
• Global Power switches the amplifier's main power supply. The network connection stays up while it is off, so the driver can switch it back on.
Zone Power
Tag: Power
Use this tag for power toggle buttons and feedback of the current power state.
Tag: Power On
Tag: Power Off
Use these tags for explicit power-on / power-off buttons.
• Power: On / Off / Toggle
• Power: Switches the amplifier zone on or off. Off also mutes the zone; On unmutes it.
• Power: Boolean - true while the zone is on
The Power On and Power Off events fire when the zone power changes, including changes made at the amplifier. Switching the zone off also mutes it, and switching it on unmutes it; the Mute variable shows this straight away.
Global Power
Tag: Global Power
Use this tag for global power toggle buttons and feedback of the current state.
Tag: Global Power On
Tag: Global Power Off
Use these tags for explicit global power on / off buttons.
• Global Power: On / Off / Toggle
• Global Power: Switches the amplifier's main power supply on or off.
• Global Power: Boolean - true while the main power supply is on
The Global Power On and Global Power Off events fire when global power changes, including changes made from the amplifier's web interface.
Volume and Mute
Volume can be controlled as a slider through directly setting the value with Set Volume, or through stepping buttons with Volume Up and Volume Down. Mute mutes and unmutes the amplifier.
Tag: Volume
Use this tag to initialize volume sliders (Set Volume function) and feedback of the current volume level (Volume variable).
Tag: Volume Up
Tag: Volume Down
Use these tags for volume step-up / step-down buttons (Volume Up / Volume Down functions).
Tag: Mute
Use this tag for mute toggle buttons and feedback of the current mute state (Mute variable).
Tag: Mute On
Tag: Mute Off
Use these tags for explicit mute-on / mute-off buttons.
Volume Ramping
A single press of Volume Up or Volume Down always changes the volume by 1. When the button is held, the driver ramps: steps of 1 for the first second, then the step grows by 1 every half second up to the Ramp Max Step set on the function (2 to 6, default 4). A higher Ramp Max Step gives a faster ramp. Releasing the button stops the ramp straight away.
For the driver to see a held button, the button must repeat while it is held:
• Set the button to Sustain mode in Integration Designer.
• Set the delay between repeats to 200 ms. This is the value the driver was tested with.
• Set Volume: Level (0 to 100)
• Set Volume: Sets the volume to an exact level; useful for sliders or macros.
• Volume Up: Ramp Max Step (2 to 6)
• Volume Up: Steps the volume up by 1, ramping while held.
• Volume Down: Ramp Max Step (2 to 6)
• Volume Down: Steps the volume down by 1, ramping while held.
• Mute: On / Off / Toggle
• Mute: Mutes, unmutes or toggles mute.
• Volume: Integer 0-100 - the current volume
• Mute: Boolean - true while the amplifier is muted
Bass
The bass level can be set directly or stepped. Bass does not ramp: each press steps by the Step set on the function.
Tag: Bass
Use this tag to initialize bass sliders (Set Bass function) and feedback of the current level (Bass variable).
Tag: Bass Up
Tag: Bass Down
Use these tags for bass step-up / step-down buttons.
• Set Bass: Level (-10 to 10)
• Set Bass: Sets the bass to an exact level.
• Bass Up: Step (1 to 10)
• Bass Up: Raises the bass by the given step.
• Bass Down: Step (1 to 10)
• Bass Down: Lowers the bass by the given step.
• Bass: Integer -10 to 10 - the current bass level
EQ Presets
The amplifier stores six EQ presets, which are named and saved in AudioControl's web interface (for example Acoustic, Bright and Party). The driver recalls them by number and shows the name of the preset in use.
Tag: EQ Preset 1 ... EQ Preset 6
Use these tags for buttons that recall a preset (Recall EQ Preset function). Name the buttons to match the presets saved on the amplifier.
Tag: EQ Preset
Use this tag for feedback of the current preset number (EQ Preset variable).
• Recall EQ Preset: Preset (Preset 1 to Preset 6)
• Recall EQ Preset: Recalls the given EQ preset. Recalling a preset can also change the bass level.
• EQ Preset: Integer 0-6 - the preset in use. 0 when the amplifier's EQ has been changed and no longer matches a saved preset
• EQ Preset Name: String - the name of the preset in use, as saved on the amplifier. Shows "unsaved values" when EQ Preset is 0
Signal Sense
Turn Signal Sense On or Off
Tag: Signal Sense
Use this tag for signal sense toggle buttons and feedback.
Tag: Signal Sense On
Tag: Signal Sense Off
Use these tags for explicit signal sense on / off buttons.
• Signal Sense: On / Off / Toggle
• Signal Sense: Turns signal sense on or off.
• Signal Sense: Boolean - true when the driver last turned signal sense on
Lip Sync
Lip Sync Up and Lip Sync Down add or remove delay from the subwoofer output, to line it up with the picture or with other speakers.
Tag: Lip Sync Up
Tag: Lip Sync Down
Use these tags for lip sync step-up / step-down buttons.
• Lip Sync Up: (none)
• Lip Sync Up: Increases the delay by one step.
• Lip Sync Down: (none)
• Lip Sync Down: Decreases the delay by one step.
Health Monitoring
The driver reads the amplifier's health on every poll. Fault gives a single flag for an alarm indicator: it is true while a short circuit is reported or any status is not "Normal".
• Fault: Boolean - true while any fault is reported
• Temperature: Integer - the amplifier temperature
• Temperature Units: String - "F" or "C", following the amplifier's web interface display setting
• Temperature Status: String - for example "Normal"
• Voltage Status: String - for example "Normal"
• Protection Status: String - for example "Normal"
• Thermal Protection: String - for example "Normal"
• Short Circuit: Boolean - true while a short circuit is reported
The Fault Detected and Fault Cleared events fire when Fault changes, for example to show a pop-up or send a notification.
Device Information
• Amplifier Name: String - the name set in the amplifier's web interface
• Model: String - the model the amplifier reports, for example RS500
• Firmware Version: String - the amplifier's firmware version, for example v2.0.47
Part 4 - Advanced / Maintenance
API Pass-through
Send API Command sends a command string straight to the amplifier, exactly as typed - useful for one-off diagnostics. The amplifier's reply is written to the debug log; the driver does not interpret it.
• Send API Command: Command (string), e.g. SYSTEMstat?
• Send API Command: Sends the command to the amplifier and logs its reply.
Part 5 - Troubleshooting and Support
Troubleshooting
Symptom: nothing in the driver works
If none of the driver's functions or feedback work at all, the fault is almost always in the connection between the RTI processor and the amplifier.
• Confirm the IP Address and that the Control Port matches the port set in the amplifier's web interface (23 by default).
• Monitor Operational Mode (String) and Connection Status (Boolean). Connection Status stays false while the driver cannot connect.
• Open the amplifier's web interface from a PC on the same network to confirm it is reachable.
Symptom: the amplifier shows as muted but nobody muted it
Signal sense has probably put the amplifier into standby: the amplifier reports standby as mute. It wakes by itself when an input signal returns. See Part 3, Signal Sense.
Symptom: no sound although Power reads on
• Check Global Power: the zone still reads on while the main power supply is off.
• Check Mute, and whether signal sense has put the amplifier into standby.
Symptom: the Signal Sense variable is blank or wrong
The amplifier cannot report this setting, so the variable only follows the driver's own commands. Use the Signal Sense On or Signal Sense Off function once so it matches the amplifier. The driver starts it as off.
Symptom: Lip Sync Up stops having any effect
The amplifier's control protocol limits lip sync to about 16 ms. Set longer delays in the amplifier's web interface.
Symptom: holding Volume Up only steps by 1
The button is not repeating. Set it to Sustain mode with a repeat delay - see Part 3, Volume Ramping.
Advanced Diagnostics
Use driver debug logging when the checks above do not explain the problem.
Debug is sent to RTI's TraceViewer tool, prefixed AudioControlRS. Send API Command replies also appear here.
Manufacturer Support
For further support with the AudioControl amplifier itself, visit:
https://www.audiocontrol.com/
Part 6 - Reference
Appendix A - Driver Actions and Function Quick Reference
• Power: Power
• Power: Zone power on/off/toggle
• Power: All models
• Global: Global Power
• Global: Main power supply on/off/toggle
• Global: All models
• Global: Signal Sense
• Global: Signal sense on/off/toggle
• Global: All models
• Lip Sync: Lip Sync Up / Lip Sync Down
• Lip Sync: Step the lip sync delay
• Lip Sync: All models
• Volume: Set Volume
• Volume: Set an exact volume level
• Volume: All models
• Volume: Volume Up / Volume Down
• Volume: Step the volume, ramping while held
• Volume: All models
• Volume: Mute
• Volume: Mute/unmute/toggle
• Volume: All models
• Bass: Set Bass
• Bass: Set an exact bass level
• Bass: All models
• Bass: Bass Up / Bass Down
• Bass: Step the bass level
• Bass: All models
• EQ Preset: Recall EQ Preset
• EQ Preset: Recall EQ preset 1-6
• EQ Preset: All models
• Custom Commands: Send API Command
• Custom Commands: Send a raw command to the amplifier
• Custom Commands: All models
Appendix B - Variable Reference
• Status: Connection Status
• Status: Boolean
• Status: True once the driver is connected
• Status: Operational Mode
• Status: String
• Status: Current connection state, e.g. Connecting, Operational
• Power: Power
• Power: Boolean
• Power: Zone power
• Global: Global Power
• Global: Boolean
• Global: Main power supply
• Global: Signal Sense
• Global: Boolean
• Global: Last signal sense state set by the driver
• Volume: Volume
• Volume: Integer 0-100
• Volume: Current volume
• Volume: Mute
• Volume: Boolean
• Volume: Mute state (also true in signal sense standby)
• Bass: Bass
• Bass: Integer -10 to 10
• Bass: Current bass level
• EQ Preset: EQ Preset
• EQ Preset: Integer 0-6
• EQ Preset: Preset in use; 0 if unsaved
• EQ Preset: EQ Preset Name
• EQ Preset: String
• EQ Preset: Name of the preset in use
• Health: Fault
• Health: Boolean
• Health: True while any fault is reported
• Health: Temperature
• Health: Integer
• Health: Amplifier temperature
• Health: Temperature Units
• Health: String
• Health: "F" or "C"
• Health: Temperature Status
• Health: String
• Health: e.g. Normal
• Health: Voltage Status
• Health: String
• Health: e.g. Normal
• Health: Protection Status
• Health: String
• Health: e.g. Normal
• Health: Thermal Protection
• Health: String
• Health: e.g. Normal
• Health: Short Circuit
• Health: Boolean
• Health: True while a short circuit is reported
• Device Info: Amplifier Name
• Device Info: String
• Device Info: Name set on the amplifier
• Device Info: Model
• Device Info: String
• Device Info: Model the amplifier reports
• Device Info: Firmware Version
• Device Info: String
• Device Info: Amplifier firmware version
Appendix C - Event Reference
• Status: Connection Status Changed
• Status: Fires when the driver connects or loses its connection
• Power: Power On / Power Off
• Power: Fires when zone power changes
• Global: Global Power On / Global Power Off
• Global: Fires when global power changes
• Health: Fault Detected / Fault Cleared
• Health: Fires when the Fault variable changes
Appendix D - Tag Reference
Power (Power)
• Function usage: F/V
• Variable usage: Power toggle and its feedback
Power (Power On / Power Off)
• Function usage: F
• Variable usage: Power on / off
Global (Global Power)
• Function usage: F/V
• Variable usage: Global power toggle and its feedback
Global (Global Power On / Global Power Off)
• Function usage: F
• Variable usage: Global power on / off
Global (Signal Sense)
• Function usage: F/V
• Variable usage: Signal sense toggle and its feedback
Global (Signal Sense On / Signal Sense Off)
• Function usage: F
• Variable usage: Signal sense on / off
Lip Sync (Lip Sync Up / Lip Sync Down)
• Function usage: F
• Variable usage: Step the lip sync delay
Volume (Volume)
• Function usage: F/V
• Variable usage: Set Volume and its feedback
Volume (Volume Up / Volume Down)
• Function usage: F
• Variable usage: Step the volume
Volume (Mute)
• Function usage: F/V
• Variable usage: Mute toggle and its feedback
Volume (Mute On / Mute Off)
• Function usage: F
• Variable usage: Mute on / off
Bass (Bass)
• Function usage: F/V
• Variable usage: Set Bass and its feedback
Bass (Bass Up / Bass Down)
• Function usage: F
• Variable usage: Step the bass
EQ Preset (EQ Preset 1 ... EQ Preset 6)
• Function usage: F
• Variable usage: Recall the preset
EQ Preset (EQ Preset)
• Function usage: V
• Variable usage: Current preset number
Appendix E - Commissioning Checklist
• Amplifier IP address recorded and stable/reserved
• Control Port matches the port set in the amplifier's web interface
• Model setting matches the amplifier, and the Model variable agrees
• Connection Status reads true
• Basic Volume Up test passed, with Volume feedback confirmed
• Volume buttons set to Sustain with a 200 ms repeat delay, and ramping checked
• Power and Global Power checked, if used
• EQ presets named on the amplifier and recall checked, if used
• Signal sense set to a known state with the driver, if used
• Fault indicator and events checked, if used
Appendix F - Version / Test Information
Driver version history
Version 1.00 – 03/11/2026
• Initial Driver release
System testing information
Integration Designer: Version 11.16
XP Processor Model: XP-8v
XP Processor Firmware: 26.6.1
Device Model(s) tested: RS500 (firmware v2.0.47)
Disclaimer of liability
This driver and its documentation are provided by Janus Technology Ltd. in good faith and have been tested against the models and firmware versions listed above. Janus Technology Ltd. accepts no liability for loss or damage arising from the use of this driver outside those conditions, or from changes made to the connected unit's firmware or configuration after testing. Always prove basic functionality (see Part 2) before relying on this driver in a live installation.