AchKayEm Solutions makes control drivers and utility modules for Q-SYS, Crestron and RTI. The Smart Timer is one of its utilities, the same timer on all three platforms: a countdown or count-up timer with staged warnings and a completion event, for room lock-outs, presentation and stage timers, inactivity shut-downs and anything else that should happen after a set time.

This driver needs no device. It runs on the processor: functions start, pause, resume and reset it, set its duration and its warnings; variables show the time, the state and the progress; events fire at each warning and at completion, so a macro can act on them.

Features

  • Count Down or Count Up, up to 99:59:59. Count Down shows the time left and completes at zero; Count Up shows the time elapsed and completes at the duration, or counts on with none.
  • Start, Pause, Resume, Reset, and Activity: a restart from zero from any state, for an inactivity timer that every touch re-arms. Pause / Resume in one button for a panel.
  • Up to five warning stages, each with its own threshold, each armed or not, each firing once per run: Count Down when the time left reaches it, Count Up when the time elapsed does.
  • Triggers: a warning or the completion fires an event, and turns on its trigger variable for the Pulse Duration, or until Reset (Maintain).
  • Auto Reset: back to Idle by itself after completing.
  • Feedback: the time as HH:MM:SS, the duration, the seconds elapsed and left, the progress in percent, the state as text and as one variable per state, and the last event.
  • Steppers that repeat while held, for every hour, minute and second field.

Supported devices

None needed: the timer runs on the RTI processor itself.

Requirements

  • An AchKayEm Solutions license for the processor. Without one the driver runs a 30-minute trial.
  • Internet access from the processor only for online license activation. The timer never needs it.

Version 1.0. The instructions in the download list every setting, function, variable and event.

This driver is developed by AchKayEm Solutions, LLC and is not endorsed by or affiliated with AchKayEm Solutions, LLC or Remote Technologies Incorporated (RTI). "AchKayEm" and "RTI" are trademarks of their respective owners, used for identification only.

AchKayEm Smart Timer | Version 1.0

Introduction & Manufacturer Profile

AchKayEm Solutions makes control drivers and utility modules for Q-SYS, Crestron and RTI. The Smart Timer is one of its utilities, the same timer on all three platforms: a countdown or count-up timer with staged warnings and a completion event, for room lock-outs, presentation and stage timers, inactivity shut-downs and anything else that should happen after a set time.

This driver needs no device. It runs on the processor: functions start, pause, resume and reset it, set its duration and its warnings; variables show the time, the state and the progress; events fire at each warning and at completion, so a macro can act on them.

Important Note

• One timer per driver instance. Add the driver once for each timer a system needs.

• The Duration fields at 0 mean the Default Duration setting. A duration changed while the timer is running applies at the next Start, Activity or Reset.

• Warnings are armed at start. Every stage up to Warning Stages starts armed, spread evenly across the default duration; Warning Enable and Warning Toggle disarm and re-arm a stage.

Version History

• 1.0 (2026-11-24): The first full release. The timer is unchanged from 0.4.

• 0.4 (2026-11-20): Beta. The sample project shows every license message in full, on every panel.

• 0.3 (2026-11-20): Beta. A license key or activation code from AchKayEm Vault licenses the driver.

• 0.2 (2026-11-20): Beta. In Count Down, Progress falls from 100 to 0 as Time does; online activation with a license key completes; offline activation codes are reported to Vault.

• 0.1 (2026-11-17): Beta. The first release: countdown and count-up, up to five warning stages, pulse or maintained triggers, auto reset, the activity restart, and a sample project.

Driver Features

• Count Down or Count Up, up to 99:59:59. Count Down shows the time left and completes at zero; Count Up shows the time elapsed and completes at the duration, or counts on with none.

• Start, Pause, Resume, Reset, and Activity: a restart from zero from any state, for an inactivity timer that every touch re-arms. Pause / Resume in one button for a panel.

• Up to five warning stages, each with its own threshold, each armed or not, each firing once per run: Count Down when the time left reaches it, Count Up when the time elapsed does.

• Triggers: a warning or the completion fires an event, and turns on its trigger variable for the Pulse Duration, or until Reset (Maintain).

• Auto Reset: back to Idle by itself after completing.

• Feedback: the time as HH:MM:SS, the duration, the seconds elapsed and left, the progress in percent, the state as text and as one variable per state, and the last event.

• Steppers that repeat while held, for every hour, minute and second field.

How a run goes

1. Idle: the time shows the duration (Count Down) or 00:00:00 (Count Up).

2. Start (or Activity): Running, from zero, with the duration in the fields.

3. Every second the time moves on. A stage whose threshold is reached fires: its event, its trigger.

4. At the duration: Completed, the completion event and trigger. No warning fires on that second.

5. Reset (or Auto Reset): back to Idle, every trigger off, every stage ready to fire again.

A warning stage fires at most once per run, never with a threshold of 0, and never when its threshold is past the point the run has reached (a threshold above the duration in Count Down, or at or above it in Count Up). Two stages with the same threshold fire together.

Supported Devices

None needed: the timer runs on the RTI processor itself.

System Requirements & Prerequisites

Integration Designer

Minimum: 10.0 or later

RTI processor

Minimum: RTI XP-series processors that run drivers.

Script engine (runtime)

Minimum: 24 or later. Integration Designer checks the processor's firmware before it downloads the driver, and refuses an older one.

• An AchKayEm Solutions license for the processor. Without one the driver runs a 30-minute trial.

• Internet access from the processor only for online license activation. The timer never needs it.

Licensing

The driver runs a 30-minute trial each time it starts, until a license is applied. When the trial ends, Start, Resume and Activity are refused (Status Message says "Control blocked"); Pause, Reset, the fields and the warning toggles keep working, and a run in progress completes.

To license it, paste a license key or an activation code from vault.achkayem-solutions.com into the License Key setting:

• License key (online): the processor activates against AchKayEm Vault over the internet once, then keeps a signed license and stays licensed across reboots with no network.

• Activation code (offline): for a processor with no internet route. An activation code is locked to one processor's MAC address, which has to be assigned in Vault before the code is made. When a code does not fit, TraceViewer shows the processor's MAC.

The Licensed, License Status, Licensed To and Trial Remaining variables show the license state.

Device Setup

1. In Integration Designer, add the driver to the processor, once for each timer.

2. In its Source Properties choose the Timer Mode, the Default Duration (HH:MM:SS), the number of Warning Stages, the Trigger Type and, for Pulse, the Pulse Duration.

3. Enter a License Key, or leave it blank to evaluate on the trial, and send the project.

4. Bind a button to Start, a label to Time, and attach a macro to the Completed event.

The sample project has a ready-made page: the time, the progress, Start, Pause / Resume and Reset, the duration with its steppers, Activity, and the warning stages with their switches and steppers.

Driver Configuration

The settings are in the driver's Source Properties in Integration Designer. They are read when the driver starts.

Timer

Timer Mode

Default: Count Down

Count Down shows the time left and completes at zero; Count Up shows the time elapsed and completes at the duration (with no duration it counts on). Choices: Count Down, Count Up.

Default Duration

Default: 00:30:00

The duration used when the Duration fields are all 0, as HH:MM:SS (up to 99:59:59). Anything else uses 00:30:00 and says so in Last Error. The fields start at this value.

Warning Stages

Default: 3

How many warning stages exist (0-5). At start they are spread evenly across the default duration and armed. Choices: 0-5.

Trigger Type

Default: Pulse

Pulse: a warning or completion trigger variable is on for the pulse duration. Maintain: it stays on until Reset, Start or Activity. Either way the event fires once. Choices: Pulse, Maintain.

Pulse Duration (ms)

Default: 500

How long a pulse lasts, 50-5000 ms.

Auto Reset

Default: Off

Return to Idle by itself after completing: the pulse duration and 500 ms after completion (Pulse), or after holding the completion 500 ms (Maintain).

Licensing

License Key

Default: (blank)

License key or offline activation code. Leave blank to run the 30-minute trial. Paste a full activation code to activate with no network call, or a short key to activate online against Vault; either way the signed licence is stored so it survives reboots without network access.

Diagnostics

Enable Trace

Default: Off

Add debug lines to TraceViewer. The timer already logs every state change, warning and refusal with this off; Run Diagnostics prints a full report either way.

Functions

Start, Resume, Activity and the resume of Pause / Resume are refused after the trial; everything else keeps working. A field that is out of range is set to the nearest value in range. The steppers repeat while the button is held.

Timer

Start

Starts a run from zero with the duration in force. Ignored while running; from Paused or Completed it is a new run, not a resume.

Pause

Holds a running timer. The part of a second already counted is kept.

Resume

Continues a paused timer from where it was held.

Pause / Resume

Pauses a running timer and resumes a paused one: one button for both.

Reset

Back to Idle: the time to the start, every trigger off, every stage ready again, and the duration re-read from the fields. Cancels a pending auto reset.

Activity

Restarts from zero, whatever the state, a run in progress included: Reset and Start in one. Bind it to every touch for an inactivity timer.

Duration

Set Duration

Parameters: Hours: 0 to 99, default 0; Minutes: 0 to 59, default 30; Seconds: 0 to 59, default 0

Sets the duration's hours, minutes and seconds. All three at 0 means the Default Duration setting.

Set Duration Hours

Parameters: Hours: 0 to 99, default 0

Sets the duration's hours field.

Set Duration Minutes

Parameters: Minutes: 0 to 59, default 30

Sets the duration's minutes field.

Set Duration Seconds

Parameters: Seconds: 0 to 59, default 0

Sets the duration's seconds field.

Duration Hours Up

Adds an hour to the duration (up to 99, no wrap). Repeats every 200 ms while the button is held.

Duration Hours Down

Takes an hour off the duration (down to 0, no wrap). Repeats every 200 ms while the button is held.

Duration Minutes Up

Adds a minute to the duration (up to 59). Repeats every 200 ms while the button is held.

Duration Minutes Down

Takes a minute off the duration. Repeats every 200 ms while the button is held.

Duration Seconds Up

Adds a second to the duration (up to 59). Repeats every 200 ms while the button is held.

Duration Seconds Down

Takes a second off the duration. Repeats every 200 ms while the button is held.

Warnings

Set Warning

Parameters: Stage: Stage 1-5 (default Stage 1); Hours: 0 to 99, default 0; Minutes: 0 to 59, default 5; Seconds: 0 to 59, default 0

Sets a stage's threshold. It is read every second, so a change counts from the next second; a threshold moved past the point the run has reached does not fire.

Warning Enable

Parameters: Stage: Stage 1-5 (default Stage 1); State: Off, On (default On)

Arms (On) or disarms (Off) a stage. A disarmed stage never fires.

Warning Toggle

Parameters: Stage: Stage 1-5 (default Stage 1)

Arms a disarmed stage and disarms an armed one.

Warning Hours Up

Parameters: Stage: Stage 1-5 (default Stage 1)

Adds an hour to a stage's threshold. Repeats every 200 ms while the button is held.

Warning Hours Down

Parameters: Stage: Stage 1-5 (default Stage 1)

Takes an hour off a stage's threshold. Repeats every 200 ms while the button is held.

Warning Minutes Up

Parameters: Stage: Stage 1-5 (default Stage 1)

Adds a minute to a stage's threshold. Repeats every 200 ms while the button is held.

Warning Minutes Down

Parameters: Stage: Stage 1-5 (default Stage 1)

Takes a minute off a stage's threshold. Repeats every 200 ms while the button is held.

Warning Seconds Up

Parameters: Stage: Stage 1-5 (default Stage 1)

Adds a second to a stage's threshold. Repeats every 200 ms while the button is held.

Warning Seconds Down

Parameters: Stage: Stage 1-5 (default Stage 1)

Takes a second off a stage's threshold. Repeats every 200 ms while the button is held.

System

Activate License

Tries activation again with the License Key setting, without restarting the driver; for example once the processor has internet access.

Run Diagnostics

Prints the settings, the state, the warnings and the license to TraceViewer. Works with Enable Trace off.

Variables

Timer

State

Type: Text

Idle, Running, Paused or Completed.

Idle

Type: Boolean

Values: true / false; as text: true "Idle", false blank

True while idle, for a button state or an LED.

Running

Type: Boolean

Values: true / false; as text: true "Running", false blank

True while running.

Paused

Type: Boolean

Values: true / false; as text: true "Paused", false blank

True while paused.

Completed

Type: Boolean

Values: true / false; as text: true "Completed", false blank

True once the run has completed, until Reset, Start or Activity.

Time

Type: Text

The time as HH:MM:SS: the time left in Count Down, the time elapsed in Count Up.

Duration

Type: Text

The duration in force for this run, as HH:MM:SS.

Elapsed Seconds

Type: Integer

Values: 0 to 359999

Seconds since the run started.

Remaining Seconds

Type: Integer

Values: 0 to 359999

Seconds left; 0 in a Count Up with no duration.

Remaining Text

Type: Text

Seconds left as text; "--" in a Count Up with no duration.

Progress (%)

Type: Integer

Values: 0 to 100

The part of the duration that Time shows, 0-100 %, for a bar graph: in Count Up the part elapsed (rises from 0 to 100), in Count Down the part left (falls from 100 to 0). 0 with no duration.

Completion Trigger

Type: Boolean

Values: true / false; as text: true "Complete", false blank

On when the run completes: for the Pulse Duration, or until Reset (Maintain).

Timer Mode

Type: Text

The Timer Mode setting: Count Down or Count Up.

Status Message

Type: Text

The state in words, and "Control blocked" when the trial has ended.

Last Event

Type: Text

The last thing the timer did: started, paused at, a warning fired at, completed.

Duration

Duration Hours

Type: Integer

Values: 0 to 99

The duration's hours field.

Duration Minutes

Type: Integer

Values: 0 to 59

The duration's minutes field.

Duration Seconds

Type: Integer

Values: 0 to 59

The duration's seconds field.

Warnings

Warning Stages

Type: Integer

Values: 0 to 5

The Warning Stages setting.

Warning 1-5 Trigger

Type: Boolean

Values: true / false; as text: true "Fired", false blank

On when the stage fires: for the Pulse Duration, or until Reset (Maintain).

Warning 1-5 Enabled

Type: Boolean

Values: true / false; as text: true "On", false "Off"

True while the stage is armed.

Warning 1-5 Available

Type: Boolean

Values: true / false; as text: true "In use", false "Not used"

True for a stage the Warning Stages setting includes; a stage above it never fires.

Warning 1-5 Time

Type: Text

The stage's threshold as HH:MM:SS.

Warning 1-5 Hours

Type: Integer

Values: 0 to 99

The stage's hours field.

Warning 1-5 Minutes

Type: Integer

Values: 0 to 59

The stage's minutes field.

Warning 1-5 Seconds

Type: Integer

Values: 0 to 59

The stage's seconds field.

Licensing

Licensed

Type: Boolean

Values: true / false; as text: true "Licensed", false "Unlicensed"

True once a license is held.

License Status

Type: Text

Trial with the time left, Activated, or why activation failed.

Licensed To

Type: Text

The licensee the license names.

Trial Remaining

Type: Text

Time left in the trial, as mm:ss.

Diagnostics

Last Error

Type: Text

The last refused command, or a Default Duration that is not HH:MM:SS; blank when none.

Diagnostics

Type: Text

One line with the mode, state, duration, elapsed seconds and counters, for support.

Events

Timer

Started

Start or Activity began a run.

Paused

The timer was paused.

Resumed

The timer was resumed.

Reset

The timer was reset, by Reset or by Auto Reset.

Completed

The run reached its duration.

Warnings

Warning 1

Stage 1 fired.

Warning 2

Stage 2 fired.

Warning 3

Stage 3 fired.

Warning 4

Stage 4 fired.

Warning 5

Stage 5 fired.

Licensing

License Activated

A license is applied.

Trial Expired

The 30-minute trial ends with no license.

Autoprogramming Support

This driver does not autoprogram: it declares no page templates and no button tags. Place its functions and variables on pages by hand.

A timer is not an AV source, so it has no place in Integration Designer's source templates. Start from the sample project, or bind its functions and variables by hand.

Limitations

• One second steps. The time moves in whole seconds, each within a tenth of a second of the true second; a pulse ends within a tenth of a second of its duration.

• A run does not survive a restart. When the processor or the driver restarts, the timer starts Idle, with the settings' duration and warnings.

• The fields are not stored. A duration or a threshold set from a panel lasts until the driver restarts; set the defaults in the settings.

• Warnings at start are spread evenly across the default duration; set them with Set Warning (or a startup macro) for other thresholds.

• Licensing: without a license the driver runs a 30-minute trial, then refuses Start, Resume and Activity. An offline activation code works only on the processor whose MAC it was made for.

Support Contact

AchKayEm Solutions, LLC, dealer support:

• Email: support@achkayem-solutions.com

• Hours: Monday to Friday, 9 am to 5 pm Central Time

• Licenses and activation codes: https://vault.achkayem-solutions.com

Troubleshooting

Start does nothing; Status Message says Control blocked

Cause and fix: The trial has ended, or the license does not fit this processor. Pause and Reset still work.

The duration is 00:30:00 whatever the setting says

Cause and fix: The Default Duration setting is not HH:MM:SS (Last Error says so). Use two digits each, with colons.

A warning never fires

Cause and fix: The stage is above Warning Stages, disarmed, at 00:00:00, or past the point the run reached. Run Diagnostics lists each stage.

The time jumps back to the start mid-run

Cause and fix: Something called Activity: every Activity restarts the run.

When you contact support, include

• The driver version, the processor model and its firmware version.

• The settings, and State, Time and Diagnostics exactly as shown.

• A TraceViewer log from the driver starting up to the failure.

Copyright and trademarks

This driver is developed by AchKayEm Solutions, LLC and is not endorsed by or affiliated with AchKayEm Solutions, LLC or Remote Technologies Incorporated (RTI). "AchKayEm" and "RTI" are trademarks of their respective owners, used for identification only.

Copyright (c) 2026 AchKayEm Solutions, LLC. All rights reserved.

Please log in to leave a comment.