Driver Details

New

AchKayEm Matrix Control Router

By: AchKayEm Solutions
Updated: Nov. 25, 2026
Download Driver Purchase License
Rating: 0.0 (0 ratings)
Log in to rate this driver

AchKayEm Solutions makes control drivers and utility modules for Q-SYS, Crestron and RTI. The Matrix Control Router is one of its utilities: a virtual matrix that runs on the RTI processor and keeps track of which input is on which output, for jobs with many sources and many zones or displays (a sports bar's TVs and cable boxes, a house's rooms and sources, AV-over-IP encoders and decoders).

This driver needs no device. Each panel picks the output it controls and routes an input to it; the driver remembers every route, shows names, lists and flags on the panels, and fires an event for each route, to which you attach the macro that switches your real equipment.

Features

  • Up to 150 inputs by 150 outputs, sized by two settings. A 27 x 148 job shows 27 inputs and 148 outputs in Integration Designer and nothing more.
  • Your own names everywhere: the variable "Bar TV 37 Selected", the event "Cable 5 to Bar TV 37", the choice "Select Output: Bar TV 37".
  • Each panel picks its output: by a button per output, by the Output List, or by Next and Previous. Routes are made from the panel by a button per input, the Input List, or Next and Previous.
  • Several outputs at once: Toggle Output adds an output to the panel's group or takes it out, Select Every Output takes them all, and one input press then routes to every one of them.
  • Input first, then Send: Pick Input holds an input without routing it; select the outputs, in any order, and Send Picked Input routes it to all of them.
  • A route event per input and output, plus Input Changed and Cleared per output, Now In Use and No Longer In Use per input, and Route Changed for any route.
  • Allowed Inputs per output (numbers and ranges, such as 1:12,15): the output's Input List, its route events and the routes the driver accepts.
  • Actions: up to 10 named actions (Power On, Volume Up ...), each an event per output; Run Action fires the one for the panel's outputs, so one Volume Up button works for whichever outputs the panel controls.
  • Follow variables: up to three integer, text and true/false variables of other drivers per input and per output, shown on the panel as Current Output and Current Input variables (a display's volume, a cable box's channel). The same values are shared variables per input and per output too ("Cable 5 Integer 1"), and each output shows its current source's ("Bar TV 37 Source Integer 1"), for macros and conditions.
  • Shared variables per input and output: name, number, current source and in-use, for a status page of every output or a macro's condition, with no panel selecting anything.
  • Routes remembered through a processor restart; Start-up Output for every panel.

Supported devices

Any equipment your macros can control: matrix switchers, AV-over-IP encoders and decoders, displays, audio zones. The driver talks to no device itself.

Requirements

  • At least one two-way panel to see the per-panel variables and lists.
  • A license from AchKayEm Solutions for use past the 30-minute trial.

Version 1.0. The instructions in the download list every setting, function, variable and event.

This driver is developed by AchKayEm Solutions, LLC and is not endorsed by or affiliated with AchKayEm Solutions, LLC or Remote Technologies Incorporated (RTI). "AchKayEm" and "RTI" are trademarks of their respective owners, used for identification only.

AchKayEm Matrix Control Router | Version 1.0

Introduction & Manufacturer Profile

AchKayEm Solutions makes control drivers and utility modules for Q-SYS, Crestron and RTI. The Matrix Control Router is one of its utilities: a virtual matrix that runs on the RTI processor and keeps track of which input is on which output, for jobs with many sources and many zones or displays (a sports bar's TVs and cable boxes, a house's rooms and sources, AV-over-IP encoders and decoders).

This driver needs no device. Each panel picks the output it controls and routes an input to it; the driver remembers every route, shows names, lists and flags on the panels, and fires an event for each route, to which you attach the macro that switches your real equipment.

Important Note

• Set Number of Inputs and Number of Outputs first. Everything past them is hidden in Integration Designer: the settings, the variables, the events and the function choices. Then name your inputs and outputs; the names appear in every list, variable, event and function choice.

• The driver does not switch anything by itself. Every input and output pair has its own route event ("Cable 5 to Bar TV 37"), and the macro you attach to it runs each time that route is made. In Driver Events, open Routes to Bar TV 37 and attach to "Cable 5 to Bar TV 37" the macro that sends the real command to your matrix switcher, decoder or display. No setting or system macro number is needed.

• A panel controls one output, or several at once. Select Output picks one; Toggle Output and Select Every Output build a group, and a route, Clear or action then reaches every output in it. Several panels may control the same output, and each sees the others' routes. A one-way remote can select outputs and route to them, but shows nothing.

• After a processor restart the routes are restored (Remember Routes) without firing their events: the equipment is assumed to have kept them. Resend Route sends one again.

Version History

• 1.0 (2026-11-24): The first full release. The driver is unchanged from 0.3.

• 0.3 (2026-11-24): Beta. Each input's and output's name, number and follow variables as shared variables, and each output's current source with its follow variables, for macros, conditions and any page.

• 0.2 (2026-11-22): Beta. Several outputs at once: Toggle Output, Select Every Output, and routes, Clear, Resend, Next / Previous Input and Run Action that reach every selected output. An input can be picked first and sent to the selected outputs with Send Picked Input (Clear After Send). The sample shows both.

• 0.1 (2026-11-22): Beta. The first release: up to 150 inputs by 150 outputs, per-panel output selection, route events, Allowed Inputs, actions, follow variables, remembered routes and a sample project.

Driver Features

• Up to 150 inputs by 150 outputs, sized by two settings. A 27 x 148 job shows 27 inputs and 148 outputs in Integration Designer and nothing more.

• Your own names everywhere: the variable "Bar TV 37 Selected", the event "Cable 5 to Bar TV 37", the choice "Select Output: Bar TV 37".

• Each panel picks its output: by a button per output, by the Output List, or by Next and Previous. Routes are made from the panel by a button per input, the Input List, or Next and Previous.

• Several outputs at once: Toggle Output adds an output to the panel's group or takes it out, Select Every Output takes them all, and one input press then routes to every one of them.

• Input first, then Send: Pick Input holds an input without routing it; select the outputs, in any order, and Send Picked Input routes it to all of them.

• A route event per input and output, plus Input Changed and Cleared per output, Now In Use and No Longer In Use per input, and Route Changed for any route.

• Allowed Inputs per output (numbers and ranges, such as 1:12,15): the output's Input List, its route events and the routes the driver accepts.

• Actions: up to 10 named actions (Power On, Volume Up ...), each an event per output; Run Action fires the one for the panel's outputs, so one Volume Up button works for whichever outputs the panel controls.

• Follow variables: up to three integer, text and true/false variables of other drivers per input and per output, shown on the panel as Current Output and Current Input variables (a display's volume, a cable box's channel). The same values are shared variables per input and per output too ("Cable 5 Integer 1"), and each output shows its current source's ("Bar TV 37 Source Integer 1"), for macros and conditions.

• Shared variables per input and output: name, number, current source and in-use, for a status page of every output or a macro's condition, with no panel selecting anything.

• Routes remembered through a processor restart; Start-up Output for every panel.

How a route goes

1. A panel with Bar TV 37 selected presses Cable 5 (Route Input, or the Input List).

2. The driver checks that Bar TV 37 allows Cable 5, then fires Cable 5 to Bar TV 37 first: the macro you attached to it switches the equipment.

3. Then Bar TV 37: Input Changed, Cable 5: Now In Use (if it was on no output), the previous input's No Longer In Use (if it is now on none), and Route Changed.

4. Every panel on Bar TV 37 shows Cable 5 as its current input; the shared variables show it too.

The same route again fires only Cable 5 to Bar TV 37, so a press re-sends a route the equipment missed. Macros attached to events fired together can run at the same time: put what must happen in order into the route event's own macro.

Several outputs at once

1. The panel presses Bar TV 1, Bar TV 2 and Patio, each with Toggle Output (or taps them in the Output List with Toggle Output Item), or presses Select Every Output. Each is lit (Selected), and Current Output Name reads "Bar TV 1 and 2 more" ("Every output" when all are selected).

2. One press of Cable 5 (Route Input, or the Input List) routes it to each of them in turn, in output order: each route fires its own events as above, so each output's route macro runs.

3. An output whose Allowed Inputs leave Cable 5 out is skipped; Status Message says how many.

Toggle Output on a selected output takes it out of the group. Select Output (or a tap in the Output List with Select Output Item) goes back to one output, and Deselect Output to none.

Input first, then Send

1. The panel presses Cable 5 with Pick Input (or taps it in the Input List with Pick Input Item). Nothing is routed: Cable 5 Picked lights, and Picked Input Name reads "Cable 5".

2. It selects the outputs with Toggle Output or Select Every Output. Ready to Send goes true once there is both an input and an output; it can light the Send button.

3. Send Picked Input routes Cable 5 to every selected output, as above.

4. With Clear After Send on (the default), the panel then picks no input and selects no output, ready for the next. A Send that is refused keeps both.

The outputs can as well be selected first and the input picked after. Clear Picked Input drops the pick.

Supported Devices

Any equipment your macros can control: matrix switchers, AV-over-IP encoders and decoders, displays, audio zones. The driver talks to no device itself.

System Requirements & Prerequisites

Integration Designer

Minimum: 10.0 or later

RTI processor

Minimum: RTI XP-series processors that run drivers.

Script engine (runtime)

Minimum: 24 or later. Integration Designer checks the processor's firmware before it downloads the driver, and refuses an older one.

• At least one two-way panel to see the per-panel variables and lists.

• A license from AchKayEm Solutions for use past the 30-minute trial.

Licensing

The driver runs a 30-minute trial at every start. After it, routes and actions are refused (Status Message says "Control blocked - not licensed") until the driver is licensed; selecting an output keeps working.

• License key: paste the key from vault.achkayem-solutions.com into License Key. The driver activates online over HTTPS and stores the signed licence, so it survives restarts without network access.

• Activation code: paste the full offline code into License Key. It activates with no network call.

• Per-processor licences are locked to the processor's MAC address; assign it in Vault first.

Activate License re-runs activation without a restart.

Device Setup

Nothing to set up on a device. In Integration Designer:

1. Add the driver, set Number of Inputs and Number of Outputs, and name them.

2. Restrict an output's Allowed Inputs where it cannot take every input.

3. In Driver Events, open Routes to each output and attach to each route event the macro that switches it.

4. Put the driver's functions and variables on your pages, or start from the sample project.

Driver Configuration

The per-input and per-output settings appear in blocks of 25, up to the counts.

Matrix

Number of Inputs

Default: 8

How many inputs (sources) the matrix has, 1-150. Inputs past it are hidden everywhere in Integration Designer and ignored by the driver.

Number of Outputs

Default: 8

How many outputs (zones, displays) the matrix has, 1-150. Outputs past it are hidden everywhere in Integration Designer and ignored by the driver.

Start-up Output

Default: 0

The output every panel controls after the processor starts, 0 for none (the panel shows No Output Selected until it picks one).

Wrap at the Ends

Default: On

Next and Previous go from the last output or input back to the first, and the other way. Off, they stop at the ends.

Remember Routes

Default: On

Keep every output's input through a processor restart. Off, every output starts with no input.

Clear After Send

Default: On

After Send Picked Input, the panel picks no input and selects no output, ready for the next. Off, both stay for another Send.

Number of Actions

Default: 0

How many named actions (Volume Up, Power Off ...) each output has. An action is an event per output that a macro is attached to; Run Action fires the one for the panel's output. Choices: 0-10.

Follow Variables per Input

Default: 0

How many of each kind of follow variable (integer, text, flag) each input has. Choices: 0-3.

Follow Variables per Output

Default: 0

How many of each kind of follow variable (integer, text, flag) each output has. Choices: 0-3.

Actions

Action 1-10 Name

Default: Action 1-10

The name of action 1-10, as it appears in the Run Action function and the events.

Inputs 1-150

Input 1-150 Name

Default: Input 1-150

The name of input 1-150: in lists, variable names, events and function choices.

Input 1-150 Follow Integer 1-3

Default: (blank)

An integer variable of another driver that belongs to input 1-150. While a panel's output has this input, the panel's Current Input Integer 1-3 shows its value.

Input 1-150 Follow Text 1-3

Default: (blank)

A text variable of another driver that belongs to input 1-150; shown in the panel's Current Input Text 1-3.

Input 1-150 Follow Flag 1-3

Default: (blank)

A true/false variable of another driver that belongs to input 1-150; shown in the panel's Current Input Flag 1-3.

Outputs 1-150

Output 1-150 Name

Default: Output 1-150

The name of output 1-150: in lists, variable names, events and function choices.

Output 1-150 Allowed Inputs

Default: 1:150

The inputs output 1-150 can take, as numbers and ranges (1:12,15). Its input list and its route events show only these; the driver refuses a route to any other.

Output 1-150 Follow Integer 1-3

Default: (blank)

An integer variable of another driver that belongs to output 1-150. While a panel's output has this output, the panel's Current Output Integer 1-3 shows its value.

Output 1-150 Follow Text 1-3

Default: (blank)

A text variable of another driver that belongs to output 1-150; shown in the panel's Current Output Text 1-3.

Output 1-150 Follow Flag 1-3

Default: (blank)

A true/false variable of another driver that belongs to output 1-150; shown in the panel's Current Output Flag 1-3.

Licensing

License Key

Default: (blank)

License key or offline activation code. Leave blank to run the 30-minute trial. Paste a full activation code to activate with no network call, or a short key to activate online against Vault; either way the signed licence is stored so it survives restarts without network access.

Diagnostics

Enable Trace

Default: Off

Add debug lines to TraceViewer. Every route, refusal and licence change is logged with this off; Run Diagnostics prints a full report either way.

Functions

"This Panel" functions act on the outputs selected on the panel that pressed them: one, or several at once. "Macros" functions name their output, for system macros and events.

This Panel

Select Output

Parameters: Output: (output name 1-150) (default (output name 1))

Makes the chosen output the only one this panel controls: its name, flags, lists and follow variables follow.

Select Output by Number

Parameters: Number: 0 to 150, default 1

Select Output by its number, for a slider or a keypad; 0 selects no output. Number: An output number; 0 selects no output.

Toggle Output

Parameters: Output: (output name 1-150) (default (output name 1))

Adds the chosen output to the outputs this panel controls, or takes it out when it is already there. A button per output with Toggle Output, lit by its Selected flag, builds a group.

Select Every Output

This panel controls every output: the next route, Clear or action reaches them all.

Next Output

The output after the one this panel selected last (from none, the first), alone. Wraps from the last to the first unless Wrap at the Ends is off.

Previous Output

The output before the one this panel selected last (from none, the last), alone. Wraps unless Wrap at the Ends is off.

Deselect Output

This panel controls no output: No Output Selected is true and its Input List shows every input, to pick one from.

Route Input

Parameters: Input: (input name 1-150) (default (input name 1))

Routes the chosen input to each of this panel's outputs, firing each route event. Outputs that do not allow it are skipped; refused when the panel has no output, or none of its outputs allows the input.

Route Input by Number

Parameters: Number: 0 to 150, default 1

Route Input by its number; 0 clears this panel's outputs. Number: An input number; 0 clears the output.

Next Input

Routes the next input in this panel's Input List to its outputs, from the input they all carry (from the start when they differ). Wraps unless Wrap at the Ends is off.

Previous Input

Routes the previous input in this panel's Input List to its outputs. Wraps unless Wrap at the Ends is off.

Clear This Output

Takes the input off each of this panel's outputs, firing their Cleared events.

Resend This Route

Fires the route event of each of this panel's outputs and its input again, for equipment that missed it.

Pick Input

Parameters: Input: (input name 1-150) (default (input name 1))

Holds the chosen input on this panel without routing it; Send Picked Input routes it. The outputs can be selected before or after.

Clear Picked Input

This panel holds no picked input. Its outputs stay selected.

Send Picked Input

Routes this panel's picked input to each of its outputs, as Route Input does. With Clear After Send on, the panel then picks no input and selects no output.

Select Output Item

Parameters: Index: 0 to 99999, default 0

Attach to the Output List: the output on the row that was tapped becomes the only one this panel controls. Index: The row of the list that was tapped (0 is the first).

Toggle Output Item

Parameters: Index: 0 to 99999, default 0

Attach to the Output List instead of Select Output Item for several outputs: a tap adds the row's output, or takes it out. Index: The row of the list that was tapped (0 is the first).

Route Input Item

Parameters: Index: 0 to 99999, default 0

Attach to the Input List: routes the input on the row that was tapped to this panel's outputs. Index: The row of the list that was tapped (0 is the first).

Pick Input Item

Parameters: Index: 0 to 99999, default 0

Attach to the Input List instead of Route Input Item to pick first: a tap picks the row's input, for Send Picked Input. Index: The row of the list that was tapped (0 is the first).

Run Action

Parameters: Action: (action name 1-10) (default (action name 1))

Fires the chosen action's event for each of this panel's outputs, such as "Bar TV 37: Volume Up".

Macros

Route

Parameters: Input: (input name 1-150) (default (input name 1)); Output: (output name 1-150) (default (output name 1))

Routes an input to an output from a macro or an event, firing its route event.

Route by Number

Parameters: Input: 0 to 150, default 1; Output: 1 to 150, default 1

Route by numbers; input 0 clears the output. Input: An input number; 0 clears the output.

Route to Every Output

Parameters: Input: (input name 1-150) (default (input name 1))

Routes the input to every output that allows it, firing each route event; Status Message says how many outputs skipped it.

Clear Output

Parameters: Output: (output name 1-150) (default (output name 1))

Takes the input off an output, firing its Cleared event.

Clear Every Output

Clears every output that has an input, then fires Every Output Cleared.

Resend Route

Parameters: Output: (output name 1-150) (default (output name 1))

Fires an output's route event again for the input it has.

Run Output Action

Parameters: Output: (output name 1-150) (default (output name 1)); Action: (action name 1-10) (default (action name 1))

Fires an action's event for the named output, from a macro.

Select Output on Every Panel

Parameters: Number: 0 to 150, default 0

Every panel controls this output (0: none), for a room's "all panels here" button. Number: An output number; 0 deselects every panel's output.

Licensing and Diagnostics

Activate License

Re-runs activation with the License Key setting, without a restart.

Run Diagnostics

Writes a full report to TraceViewer and the Diagnostics variable.

Variables

"This Panel" variables have a value for each two-way panel: each panel shows its own outputs. The others are shared by every panel.

This Panel

Current Output Name

Type: Text

The name of this panel's output; with several, the first selected and how many more ("Bar TV 1 and 2 more"), or "Every output"; empty when it has none.

Current Output Number

Type: Integer

Values: 0 to 150

The number of this panel's output; 0 for none, and for several.

Output Selected

Type: Boolean

Values: true / false; as text: true "Selected", false blank

True while this panel has at least one output, to show its controls.

No Output Selected

Type: Boolean

Values: true / false; as text: true "Select an output", false blank

True while this panel has no output, to show a "select an output" prompt.

Selected Output Count

Type: Integer

Values: 0 to 150

How many outputs this panel controls.

Several Outputs Selected

Type: Boolean

Values: true / false

True while this panel controls more than one output, to show what only a group needs.

Current Input Name

Type: Text

The name of the input on this panel's output. With several outputs, the input they all carry; when they differ, the one most of them carry and on how many, such as "Blu-ray (5 of 6)"; empty when they carry none.

Current Input Number

Type: Integer

Values: 0 to 150

The number of the input on this panel's outputs, 0 for none and when they differ.

Current Output Has Input

Type: Boolean

Values: true / false; as text: true "On", false "Off"

True while any of this panel's outputs has an input.

Picked Input Name

Type: Text

The name of the input this panel picked for Send Picked Input; empty when none.

Picked Input Number

Type: Integer

Values: 0 to 150

The number of the input this panel picked, 0 for none.

Input Picked

Type: Boolean

Values: true / false

True while this panel has picked an input.

Ready to Send

Type: Boolean

Values: true / false

True while this panel has picked an input and selected at least one output: Send Picked Input will route. Light or show the Send button with it.

Output List

Type: List

Values: list

Every output, by name, each of this panel's outputs marked. Attach Select Output Item to it, or Toggle Output Item for several.

Input List

Type: List

Values: list

The inputs this panel's outputs allow (every input while it has none). Marked: the picked input while there is one, else the inputs on its outputs. Attach Route Input Item to it, or Pick Input Item to pick first.

Current Output Integer 1-3

Type: Integer

Values: -2147483648 to 2147483647

The value of this panel's output's Follow Integer variable of that number (0 when it has none, or several outputs).

Current Output Text 1-3

Type: Text

The value of this panel's output's Follow Text variable of that number (empty for several outputs).

Current Output Flag 1-3

Type: Boolean

Values: true / false

The value of this panel's output's Follow Flag variable of that number (false for several outputs).

Current Input Integer 1-3

Type: Integer

Values: -2147483648 to 2147483647

The value of the Follow Integer variable of that number of the input on this panel's outputs (when they all carry the same one).

Current Input Text 1-3

Type: Text

The value of the Follow Text variable of that number of the input on this panel's outputs.

Current Input Flag 1-3

Type: Boolean

Values: true / false

The value of the Follow Flag variable of that number of the input on this panel's outputs.

This Panel: Outputs 1-150

(output name 1-150) Selected

Type: Boolean

Values: true / false

True on this panel while it controls that output: a button per output lights with it.

(output name 1-150) Not Selected

Type: Boolean

Values: true / false

The opposite of Selected, for a button's visibility.

This Panel: Inputs 1-150

(input name 1-150) On This Output

Type: Boolean

Values: true / false

True on this panel while that input is on its output (with several outputs, on any of them): a button per input lights with it.

(input name 1-150) Not On This Output

Type: Boolean

Values: true / false

The opposite of On This Output, for a button's visibility.

(input name 1-150) Picked

Type: Boolean

Values: true / false

True on this panel while that input is its picked input: a Pick Input button per input lights with it.

Outputs 1-150

(output name 1-150) Name

Type: Text

That output's name, as set in Output Name.

(output name 1-150) Number

Type: Integer

Values: 1 to 150

That output's number.

(output name 1-150) Current Source

Type: Text

Current Source: the name of the input on that output; empty when none. For a status page of every output.

(output name 1-150) Current Source Number

Type: Integer

Values: 0 to 150

Current Source Number: the number of the input on that output, 0 for none.

(output name 1-150) Has Input

Type: Boolean

Values: true / false; as text: true "On", false "Off"

True while that output has an input.

Inputs 1-150

(input name 1-150) Name

Type: Text

That input's name, as set in Input Name.

(input name 1-150) Number

Type: Integer

Values: 1 to 150

That input's number.

(input name 1-150) In Use

Type: Boolean

Values: true / false; as text: true "In use", false blank

True while that input is on at least one output.

(input name 1-150) Not In Use

Type: Boolean

Values: true / false

True while that input is on no output.

(input name 1-150) Output Count

Type: Integer

Values: 0 to 150

How many outputs that input is on.

Output Follow 1-150

(output name 1-150) Integer 1-3

Type: Integer

Values: -2147483648 to 2147483647

That output's own Follow Integer variable of that number (Follow Variables per Output).

(output name 1-150) Text 1-3

Type: Text

That output's own Follow Text variable of that number.

(output name 1-150) Flag 1-3

Type: Boolean

Values: true / false

That output's own Follow Flag variable of that number.

Output Source Follow 1-150

(output name 1-150) Source Integer 1-3

Type: Integer

Values: -2147483648 to 2147483647

The Follow Integer variable of that number of the input on that output (Follow Variables per Input); 0 while it has none.

(output name 1-150) Source Text 1-3

Type: Text

The Follow Text variable of that number of the input on that output; empty while it has none.

(output name 1-150) Source Flag 1-3

Type: Boolean

Values: true / false

The Follow Flag variable of that number of the input on that output; false while it has none.

Input Follow 1-150

(input name 1-150) Integer 1-3

Type: Integer

Values: -2147483648 to 2147483647

That input's own Follow Integer variable of that number, whether or not it is on an output.

(input name 1-150) Text 1-3

Type: Text

That input's own Follow Text variable of that number.

(input name 1-150) Flag 1-3

Type: Boolean

Values: true / false

That input's own Follow Flag variable of that number.

Matrix

Outputs With an Input

Type: Integer

Values: 0 to 150

How many outputs have an input.

Inputs In Use

Type: Integer

Values: 0 to 150

How many inputs are on at least one output.

Last Route

Type: Text

The last route that changed, such as "Cable 5 to Bar TV 37" or "Bar TV 37 cleared".

Status Message

Type: Text

What the driver last did or refused, in a line for a panel.

Licensing

Licensed

Type: Boolean

Values: true / false; as text: true "Licensed", false "Unlicensed"

True while the driver is licensed.

License Status

Type: Text

The licence state, or the trial time left and why it is not licensed.

Licensed To

Type: Text

The name the licence was issued to.

Trial Remaining

Type: Text

The trial time left as minutes:seconds; empty once licensed.

Diagnostics

Last Error

Type: Text

Why the last refused command was refused.

Diagnostics

Type: Text

A one-line summary of the matrix, the panels and the counts, from Run Diagnostics.

Events

Matrix

Route Changed

Any output's input changed or was cleared.

Every Output Cleared

Clear Every Output finished.

Outputs 1-150

(output name 1-150): Input Changed

That output got a different input, after the route's own event.

(output name 1-150): Cleared

That output's input was taken off.

Inputs 1-150

(input name 1-150): Now In Use

That input went onto an output when it was on none.

(input name 1-150): No Longer In Use

That input came off its last output.

(output name 1-150) Actions

(output name 1-150): (action name 1-10)

Run Action or Run Output Action asked for that action on that output. Attach the action's macro for that output.

Routes to (output name 1-150)

(input name 1-150) to (output name 1-150)

A route of that input to that output was made or re-sent, before every other event of the route. Attach the macro that switches your equipment; each output's routes are under Routes to it, only for its Allowed Inputs.

Licensing

License Activated

The driver was licensed.

Trial Expired

The 30-minute trial ended without a licence: routes and actions are refused from now.

Autoprogramming Support

This driver does not autoprogram: it declares no page templates and no button tags. Place its functions and variables on pages by hand.

The driver declares no autoprogramming templates: place its functions and variables on your pages, or start from the sample project.

Limitations

• 150 inputs and 150 outputs at most. A route is one input on one output; an output has one input at a time.

• The driver does not switch equipment. A route reaches your equipment only through the macro attached to its route event.

• Restored routes fire no events after a restart.

• A one-way remote has no per-panel variables: it can select and route, but shows nothing.

• A panel's selected outputs and picked input are not kept through a processor restart (Start-up Output selects one).

• A route to several outputs is one route after another, each with its own events and macros.

• Follow variables show another driver's value; they do not control it.

Support Contact

AchKayEm Solutions, LLC, dealer support:

• Email: support@achkayem-solutions.com

• Hours: Monday to Friday, 9 am to 5 pm Central Time

• Licenses and activation codes: https://vault.achkayem-solutions.com

Troubleshooting

• A route is refused: Last Error says why (the output does not allow the input, no output selected, no input picked, or the trial has ended).

• Nothing switches: attach a macro to the route event in Driver Events, Routes to that output.

• Run Diagnostics writes a full report to TraceViewer and the Diagnostics variable.

When you contact support, include

• The driver version, the processor model and its firmware.

• Number of Inputs and Number of Outputs, and the output and input involved.

• The Diagnostics variable or a TraceViewer capture after Run Diagnostics.

Copyright and trademarks

This driver is developed by AchKayEm Solutions, LLC and is not endorsed by or affiliated with AchKayEm Solutions, LLC or Remote Technologies Incorporated (RTI). "AchKayEm" and "RTI" are trademarks of their respective owners, used for identification only.

Copyright (c) 2026 AchKayEm Solutions, LLC. All rights reserved.

The driver runs a 30-minute trial at every start. After it, routes and actions are refused (Status Message says "Control blocked - not licensed") until the driver is licensed; selecting an output keeps working.

  • License key: paste the key from vault.achkayem-solutions.com into License Key. The driver activates online over HTTPS and stores the signed licence, so it survives restarts without network access.
  • Activation code: paste the full offline code into License Key. It activates with no network call.
  • Per-processor licences are locked to the processor's MAC address; assign it in Vault first.

Activate License re-runs activation without a restart.

Buy a license or an activation code at https://vault.achkayem-solutions.com.

Please log in to leave a comment.
Loading comments...