Driver Type
Categories
- Recent Updates
- Access Control
- Amplifier
- A/V Receiver
- Climate and Pool Control
- Disc Player / Changer
- Display
- DSP
- DVR
- Irrigation / Sprinklers
- Lighting Control
- Matrix Switch
- Media Server and Player
- Multi-Room A/V
- Networking
- Power and Rack Management
- Security
- Surveillance
- Teleconferencing
- Training
- Tuner
- Utility
- Video Projector
Driver Type
Categories
- Recent Updates
- Access Control
- Amplifier
- A/V Receiver
- Climate and Pool Control
- Disc Player / Changer
- Display
- DSP
- DVR
- Irrigation / Sprinklers
- Lighting Control
- Matrix Switch
- Media Server and Player
- Multi-Room A/V
- Networking
- Power and Rack Management
- Security
- Surveillance
- Teleconferencing
- Training
- Tuner
- Utility
- Video Projector
Allen & Heath is a British manufacturer of mixing consoles for live sound, installation and recording. The SQ series (SQ-5, SQ-6 and SQ-7) are 96 kHz digital mixers used in venues, houses of worship and live production, with 48 input channels, Aux, FX and Matrix mixes, DCAs, mute groups and scene memories.
This driver controls an SQ from an RTI XP processor over the network, using Allen & Heath's SQ MIDI protocol on TCP port 51325. It mutes and sets the level of inputs, mixes and DCAs, pans inputs, controls the sends from every input to one chosen Aux or FX mix, switches mute groups, recalls scenes, presses soft keys, and sends raw MIDI for anything else. It shows every mute, level and pan it reads as RTI variables, including changes made at the mixer.
Features
- Inputs 1-48: mute on, off and toggle; level as a percentage or in dB; 1 dB steps up and down that repeat while a button is held; pan, set or stepped. Feedback for each.
- Mix masters (LR, Aux 1-12, FX Send 1-4, Matrix 1-3): mute and level, with feedback.
- DCA 1-8: mute and level, with feedback. Mute groups 1-8: on, off and toggle, with feedback.
- Sends: the level and assign of every input to one selected Aux or FX send, with feedback. Selecting another send reads its rows.
- Scenes 1-300: recall directly, or select, step up and down, and recall the selected one.
- Soft keys 1-16: press, release and tap.
- Send MIDI Hex: any MIDI message, for what the functions do not cover (group masters, FX returns, send pans).
Supported devices
Allen & Heath SQ-5, SQ-6 and SQ-7, on mixer firmware V1.5.0 or later: the firmware Allen & Heath's "SQ MIDI Protocol" Issue 5 covers.
Requirements
- The mixer on the network, reachable from the processor on TCP port 51325.
- An AchKayEm Solutions license for the processor. Without one the driver runs a 30-minute trial.
- Internet access from the processor only for online license activation. Control never needs it.
Version 1.3. The instructions in the download list every setting, function, variable and event.
This driver is developed by AchKayEm Solutions, LLC and is not endorsed by or affiliated with Allen & Heath Ltd or Remote Technologies Incorporated (RTI). "Allen & Heath", "SQ" and "RTI" are trademarks of their respective owners, used for identification only.
Allen & Heath SQ | Version 1.3
Introduction & Manufacturer Profile
Allen & Heath is a British manufacturer of mixing consoles for live sound, installation and recording. The SQ series (SQ-5, SQ-6 and SQ-7) are 96 kHz digital mixers used in venues, houses of worship and live production, with 48 input channels, Aux, FX and Matrix mixes, DCAs, mute groups and scene memories.
This driver controls an SQ from an RTI XP processor over the network, using Allen & Heath's SQ MIDI protocol on TCP port 51325. It mutes and sets the level of inputs, mixes and DCAs, pans inputs, controls the sends from every input to one chosen Aux or FX mix, switches mute groups, recalls scenes, presses soft keys, and sends raw MIDI for anything else. It shows every mute, level and pan it reads as RTI variables, including changes made at the mixer.
Important Note
• Set the MIDI channel and Fader Law to match the mixer. The driver cannot read either from the mixer. A wrong MIDI channel connects but never answers; a wrong Fader Law makes the dB values a few dB off. Both are on the mixer under Utility > General > MIDI.
• Levels come in two forms. Level variables and Set ... Level take a percentage of the fader (0 to 100, where 93 is 0 dB under the Linear Taper law); the dB variables and Set ... Level dB use whole decibels. Bind a slider or bar graph to the percentage, a label to the dB text.
• The mixer has no login on this port. Anything that reaches TCP 51325 can control it. Keep the mixer on a trusted network.
Version History
• 1.3 (2026-11-20): The sample project's note under the scenes fits on every panel.
• 1.2 (2026-11-20): Online activation with a license key completes; offline activation codes are reported to Vault.
• 1.1 (2026-11-11): New documentation (every setting, function, variable and event); level, pan, scene and channel variables declare their ranges.
• 1.0 (2026-11-10): Initial release.
Driver Features
• Inputs 1-48: mute on, off and toggle; level as a percentage or in dB; 1 dB steps up and down that repeat while a button is held; pan, set or stepped. Feedback for each.
• Mix masters (LR, Aux 1-12, FX Send 1-4, Matrix 1-3): mute and level, with feedback.
• DCA 1-8: mute and level, with feedback. Mute groups 1-8: on, off and toggle, with feedback.
• Sends: the level and assign of every input to one selected Aux or FX send, with feedback. Selecting another send reads its rows.
• Scenes 1-300: recall directly, or select, step up and down, and recall the selected one.
• Soft keys 1-16: press, release and tap.
• Send MIDI Hex: any MIDI message, for what the functions do not cover (group masters, FX returns, send pans).
Polling and feedback
Feedback is event-driven: every value the mixer sends, whether it answers a read, echoes a command, or reports a change made at its surface, lands on the matching variable. A command shows its result at once and the mixer's own value then replaces it.
On connect, and on Resync, the driver reads every mute, level and pan it shows: 144 reads at the default 16 inputs (about a second), 304 at 48, paced at ten reads every 50 ms so the mixer is never flooded. After that it polls only a heartbeat: one read of the LR level every Heartbeat seconds (10 by default). Two unanswered heartbeats in a row close and reopen the connection.
Channel map
Inputs
Numbers: 1-48
Notes: Input Count decides how many are read on connect; every function reaches all 48.
Mixes
Numbers: LR, Aux 1-12, FX Send 1-4, Matrix 1-3
Notes: Integration Designer lists them by name. A panel passing a number uses 1 = LR, 2-13 = Aux 1-12, 14-17 = FX Send 1-4, 18-20 = Matrix 1-3.
Send mixes
Numbers: Aux 1-12, FX Send 1-4
Notes: As numbers, 1-12 = Aux 1-12 and 13-16 = FX Send 1-4.
DCAs
Numbers: 1-8
Mute groups
Numbers: 1-8
Scenes
Numbers: 1-300
Soft keys
Numbers: 1-16
Notes: An SQ-5 has 1-8.
Supported Devices
Allen & Heath SQ-5, SQ-6 and SQ-7, on mixer firmware V1.5.0 or later: the firmware Allen & Heath's "SQ MIDI Protocol" Issue 5 covers.
System Requirements & Prerequisites
Integration Designer
Minimum: 10.0 or later
RTI processor
Minimum: RTI XP-series processors that run drivers.
Script engine (runtime)
Minimum: 24 or later. Integration Designer checks the processor's firmware before it downloads the driver, and refuses an older one.
• The mixer on the network, reachable from the processor on TCP port 51325.
• An AchKayEm Solutions license for the processor. Without one the driver runs a 30-minute trial.
• Internet access from the processor only for online license activation. Control never needs it.
Licensing
The driver runs a 30-minute trial each time it starts, until a license is applied. When the trial ends, control functions are refused (Status Message says "Control blocked") while feedback and the heartbeat go on.
To license it, paste a license key or an activation code from vault.achkayem-solutions.com into the License Key setting:
• License key (online): the processor activates against AchKayEm Vault over the internet once, then keeps a signed license and stays licensed across reboots with no network.
• Activation code (offline): for a processor with no internet route. An activation code is locked to one processor's MAC address, which has to be assigned in Vault before the code is made. When a code does not fit, TraceViewer shows the processor's MAC.
The Licensed, License Status, Licensed To and Trial Remaining variables show the license state.
Device Setup
1. Connect the mixer to the network and note its IP address: Utility > Network on the mixer. Give it a static address or a DHCP reservation.
2. Note the mixer's MIDI channel and NRPN Fader Law: Utility > General > MIDI.
3. If soft keys are to be driven, assign them on the mixer first; a key with nothing assigned does nothing.
4. In Integration Designer, add the driver to the processor. In its Source Properties set Device IP Address, MIDI Channel and Fader Law to match the mixer, and Input Count to the number of inputs in use.
5. Enter a License Key, or leave it blank to evaluate on the trial, and send the project to the processor.
6. Check that Connection State reads Connected and Responding is on. Connected without Responding means the MIDI channel is wrong.
Driver Configuration
The settings are in the driver's Source Properties in Integration Designer.
Connection
Device IP Address
Default: 192.168.1.100
IP address or hostname of the SQ mixer (Utility > Network on the mixer).
TCP Port
Default: 51325
TCP port of the SQ's MIDI-over-TCP service. The mixer listens on 51325; change this only for a relay or an emulator. Valid range 1-65535.
Mixer
MIDI Channel
Default: 1
The mixer's MIDI channel (Utility > General > MIDI on the SQ). Every message carries it; a wrong channel connects but never answers. Choices: 1-16.
Fader Law
Default: Linear Taper
The mixer's NRPN Fader Law (Utility > General > MIDI). Decides how dB values and the dB feedback text are converted. Linear Taper is the mixer's default. Choices: Linear Taper, Audio Taper.
Input Count
Default: 16
How many input channels the driver reads on connect and for the send rows (1-48). Fewer inputs is a faster resync; controls still address inputs up to 48.
Heartbeat
Heartbeat (seconds)
Default: 10
How often the driver reads the LR output level to prove the mixer is answering (2-600). Two unanswered heartbeats in a row close and reopen the connection.
Licensing
License Key
Default: (blank)
License key or activation code. Leave blank to run the 30-minute trial. The driver activates online against Vault, then stores a signed offline license so it survives reboots without network access.
Diagnostics
Enable Trace
Default: Off
Log every frame sent and every chunk received to TraceViewer, on top of the driver's normal startup, connection and error messages. Leave off in normal operation - a fader drag prints a line per step. The Diagnostics > Run Diagnostics function prints a full report with this off.
Functions
Every function takes the input, mix, DCA, group, scene or soft key as a parameter, so one function covers them all. Bind them to buttons, call them from macros, or drive a level from a slider. Up, Down, Left and Right repeat while the button is held: a tap is one step, a hold is a ramp, and the mixer's own value is read back 300 ms after the last press.
Inputs
Input Mute On
Parameters: Input: 1 to 48, default 1
Mutes the input.
Input Mute Off
Parameters: Input: 1 to 48, default 1
Unmutes the input.
Input Mute Toggle
Parameters: Input: 1 to 48, default 1
Toggles the input's mute; the mixer's state is read back.
Set Input Level
Parameters: Input: 1 to 48, default 1; Level: 0 to 100, default 75
Sets the input's fader as a percentage. Bind it to a slider. Level: Level as a percentage of the fader scale: 0 = -inf, 93 = 0 dB (linear taper), 100 = +10 dB.
Set Input Level dB
Parameters: Input: 1 to 48, default 1; dB: -90 to 10, default 0
Sets the input's fader in whole dB, through the Fader Law setting. dB: Level in whole dB: -90 is -inf, +10 the top of the fader.
Input Level Up
Parameters: Input: 1 to 48, default 1
Raises the input's fader 1 dB. Repeats every 200 ms while the button is held.
Input Level Down
Parameters: Input: 1 to 48, default 1
Lowers the input's fader 1 dB. Repeats every 200 ms while the button is held.
Set Input Pan
Parameters: Input: 1 to 48, default 1; Pan: -100 to 100, default 0
Sets the input's pan. Pan: Pan: -100 full left, 0 centre, +100 full right.
Input Pan Left
Parameters: Input: 1 to 48, default 1
Moves the input's pan one step (1 of 100) left. Repeats every 200 ms while the button is held.
Input Pan Right
Parameters: Input: 1 to 48, default 1
Moves the input's pan one step (1 of 100) right. Repeats every 200 ms while the button is held.
Mixes
Mix Mute On
Parameters: Mix: LR, Aux 1-12, FX Send 1-4, Matrix 1-3 (default LR)
Mutes the mix master.
Mix Mute Off
Parameters: Mix: LR, Aux 1-12, FX Send 1-4, Matrix 1-3 (default LR)
Unmutes the mix master.
Mix Mute Toggle
Parameters: Mix: LR, Aux 1-12, FX Send 1-4, Matrix 1-3 (default LR)
Toggles the mix master's mute; the mixer's state is read back.
Set Mix Level
Parameters: Mix: LR, Aux 1-12, FX Send 1-4, Matrix 1-3 (default LR); Level: 0 to 100, default 75
Sets the mix master's fader as a percentage. Level: Level as a percentage of the fader scale: 0 = -inf, 93 = 0 dB (linear taper), 100 = +10 dB.
Set Mix Level dB
Parameters: Mix: LR, Aux 1-12, FX Send 1-4, Matrix 1-3 (default LR); dB: -90 to 10, default 0
Sets the mix master's fader in whole dB. dB: Level in whole dB: -90 is -inf, +10 the top of the fader.
Mix Level Up
Parameters: Mix: LR, Aux 1-12, FX Send 1-4, Matrix 1-3 (default LR)
Raises the mix master 1 dB. Repeats every 200 ms while the button is held.
Mix Level Down
Parameters: Mix: LR, Aux 1-12, FX Send 1-4, Matrix 1-3 (default LR)
Lowers the mix master 1 dB. Repeats every 200 ms while the button is held.
DCAs
DCA Mute On
Parameters: DCA: 1 to 8, default 1
Mutes the DCA.
DCA Mute Off
Parameters: DCA: 1 to 8, default 1
Unmutes the DCA.
DCA Mute Toggle
Parameters: DCA: 1 to 8, default 1
Toggles the DCA's mute; the mixer's state is read back.
Set DCA Level
Parameters: DCA: 1 to 8, default 1; Level: 0 to 100, default 75
Sets the DCA's fader as a percentage. Level: Level as a percentage of the fader scale: 0 = -inf, 93 = 0 dB (linear taper), 100 = +10 dB.
Set DCA Level dB
Parameters: DCA: 1 to 8, default 1; dB: -90 to 10, default 0
Sets the DCA's fader in whole dB. dB: Level in whole dB: -90 is -inf, +10 the top of the fader.
DCA Level Up
Parameters: DCA: 1 to 8, default 1
Raises the DCA 1 dB. Repeats every 200 ms while the button is held.
DCA Level Down
Parameters: DCA: 1 to 8, default 1
Lowers the DCA 1 dB. Repeats every 200 ms while the button is held.
Mute Groups
Mute Group On
Parameters: Mute Group: 1 to 8, default 1
Turns the mute group on, muting its members.
Mute Group Off
Parameters: Mute Group: 1 to 8, default 1
Turns the mute group off.
Mute Group Toggle
Parameters: Mute Group: 1 to 8, default 1
Toggles the mute group; the mixer's state is read back.
Sends
Select Send Mix
Parameters: Send Mix: Aux 1-12, FX Send 1-4 (default Aux 1)
Chooses which Aux or FX send the Send functions and variables address. The send rows blank and are read again for the new mix. Send Mix: The Aux or FX send the Send functions and variables address.
Set Send Level
Parameters: Input: 1 to 48, default 1; Level: 0 to 100, default 75
Sets the level of the input's send to the selected send mix, as a percentage. Level: Level as a percentage of the fader scale: 0 = -inf, 93 = 0 dB (linear taper), 100 = +10 dB.
Set Send Level dB
Parameters: Input: 1 to 48, default 1; dB: -90 to 10, default 0
Sets the level of the input's send to the selected send mix, in whole dB. dB: Level in whole dB: -90 is -inf, +10 the top of the fader.
Send Level Up
Parameters: Input: 1 to 48, default 1
Raises the input's send to the selected send mix 1 dB. Repeats every 200 ms while the button is held.
Send Level Down
Parameters: Input: 1 to 48, default 1
Lowers the input's send to the selected send mix 1 dB. Repeats every 200 ms while the button is held.
Send Assign On
Parameters: Input: 1 to 48, default 1
Assigns the input to the selected send mix.
Send Assign Off
Parameters: Input: 1 to 48, default 1
Removes the input from the selected send mix.
Send Assign Toggle
Parameters: Input: 1 to 48, default 1
Toggles the input's assignment to the selected send mix.
Scenes
Recall Scene
Parameters: Scene: 1 to 300, default 1
Recalls the scene on the mixer.
Select Scene
Parameters: Scene: 1 to 300, default 1
Sets Selected Scene without recalling it, for a scene picker.
Scene Up
Adds one to Selected Scene (up to 300) without recalling it.
Scene Down
Takes one from Selected Scene (down to 1) without recalling it.
Recall Selected Scene
Recalls the scene in Selected Scene.
Soft Keys
Soft Key Press
Parameters: Soft Key: 1 to 16, default 1
Presses the soft key and holds it until Soft Key Release. Soft Key: Soft Key 1-16 (an SQ-5 has 1-8).
Soft Key Release
Parameters: Soft Key: 1 to 16, default 1
Releases the soft key. Soft Key: Soft Key 1-16 (an SQ-5 has 1-8).
Soft Key Tap
Parameters: Soft Key: 1 to 16, default 1
Presses the soft key and releases it 150 ms later. Soft Key: Soft Key 1-16 (an SQ-5 has 1-8).
Raw MIDI
Send MIDI Hex
Parameters: Hex: text
Sends the given bytes to the mixer as they are, for anything the other functions do not cover. Allen & Heath's "SQ MIDI Protocol" document lists the messages. Hex: MIDI bytes as hex pairs, e.g. B0 63 00 B0 62 44 B0 06 00 B0 26 01 (spaces optional, up to 255 characters).
Connection
Resync
Reads every mute, level and pan on the driver's surface again.
Reconnect
Closes the connection to the mixer and opens it again.
Licensing
Activate License
Tries activation again with the License Key setting, without restarting the driver; for example once the processor has internet access.
Diagnostics
Run Diagnostics
Prints the configuration, every traffic counter and a hint to TraceViewer. Works with Enable Trace off.
Test Device Connection
Sends one heartbeat read and prints PASSED or FAILED to TraceViewer.
Variables
The Level variables are percentages for a slider or bar graph; the Level dB variables are text for a label ("-20.0 dB", "-inf"). Integration Designer lists each numbered variable separately (Input 1 Mute, Input 2 Mute, and so on); each row below covers the whole series.
Connection
Connection State
Type: Integer
Values: 0 = Disconnected, 1 = Connected
The network connection to the mixer.
Disconnected
Type: Boolean
Values: true / false; as text: true "Disconnected", false blank
True while disconnected, for an LED.
Connected
Type: Boolean
Values: true / false; as text: true "Connected", false blank
True while connected, for an LED.
Responding
Type: Boolean
Values: true / false; as text: true "Responding", false blank
True once the mixer has answered; false after two unanswered heartbeats. Connected but not Responding means a wrong MIDI channel or the wrong device.
Status Message
Type: Text
What the driver is doing: Connecting..., the address when up, or why not.
Last Command
Type: Text
The last function sent, for example "InputMuteOn 1".
Last Response
Type: Text
The last value received from the mixer.
Last Error
Type: Text
The last command refused, and why; blank when none.
Mixer
MIDI Channel
Type: Integer
Values: 1 to 16
The MIDI Channel setting in force.
Fader Law
Type: Text
The Fader Law setting in force: Linear Taper or Audio Taper.
Input Count
Type: Integer
Values: 1 to 48
The Input Count setting in force.
Last Input Level
Type: Text
The last input level that changed, as text, for example "Ip 3: -20.0 dB".
Last Mix Level
Type: Text
The last mix level that changed, as text, for example "Aux 2: 0.0 dB".
Scenes
Last Scene
Type: Integer
Values: 0 to 300
The last scene this driver recalled; 0 until it recalls one. The mixer does not report scene recalls, so one made at the mixer does not show.
Selected Scene
Type: Integer
Values: 1 to 300
The scene Recall Selected Scene will recall.
Inputs
Input 1-48 Mute
Type: Boolean
Values: true / false; as text: true "MUTE", false blank
True while the input is muted.
Input 1-48 Level
Type: Integer
Values: 0 to 100
The input's fader position as a percentage (93 is 0 dB under Linear Taper).
Input 1-48 Level dB
Type: Text
The input's fader in dB, as text through the Fader Law setting.
Input 1-48 Pan
Type: Integer
Values: -100 to 100
The input's pan: -100 full left, 0 centre, 100 full right.
Mixes
Mute (LR, Aux 1-12, FX Send 1-4, Matrix 1-3)
Type: Boolean
Values: true / false; as text: true "MUTE", false blank
True while the mix master is muted.
Level (LR, Aux 1-12, FX Send 1-4, Matrix 1-3)
Type: Integer
Values: 0 to 100
The mix master's fader as a percentage.
Level dB (LR, Aux 1-12, FX Send 1-4, Matrix 1-3)
Type: Text
The mix master's fader in dB, as text.
DCAs
DCA 1-8 Mute
Type: Boolean
Values: true / false; as text: true "MUTE", false blank
True while the DCA is muted.
DCA 1-8 Level
Type: Integer
Values: 0 to 100
The DCA's fader as a percentage.
DCA 1-8 Level dB
Type: Text
The DCA's fader in dB, as text.
Mute Groups
Mute Group 1-8
Type: Boolean
Values: true / false; as text: true "ON", false blank
True while the mute group is on.
Sends
Send Mix
Type: Integer
Values: 1 to 16
The selected send mix as a number (1-12 = Aux 1-12, 13-16 = FX Send 1-4).
Send Mix Name
Type: Text
The selected send mix by name, for example "Aux 1".
Send 1-48 Level
Type: Integer
Values: 0 to 100
The level of input n's send to the selected send mix, as a percentage.
Send 1-48 Level dB
Type: Text
The same in dB, as text; blank until read.
Send 1-48 Assign
Type: Boolean
Values: true / false; as text: true "ON", false blank
True while input n is assigned to the selected send mix.
Licensing
Licensed
Type: Boolean
Values: true / false; as text: true "Licensed", false "Unlicensed"
True once a license is held.
License Status
Type: Text
Trial with the time left, Activated, or why activation failed.
Licensed To
Type: Text
The licensee the license names.
Trial Remaining
Type: Text
Time left in the trial, as mm:ss.
Diagnostics
Link Diagnostics
Type: Text
One line with the address, the MIDI channel and every traffic counter (sent, values, timeouts, unknown, reconnects and more), readable in Integration Designer or on a panel.
Events
Connection
Disconnected
The network connection to the mixer goes down.
Connected
The network connection to the mixer comes up.
Responding
The mixer answers for the first time after connecting.
Not Responding
Two heartbeats in a row go unanswered.
Licensing
License Activated
A license is applied.
Trial Expired
The 30-minute trial ends with no license.
Autoprogramming Support
This driver does not autoprogram: it declares no page templates and no button tags. Place its functions and variables on pages by hand.
A mixer does not fit Integration Designer's source templates, which are built for AV sources such as receivers and players.
Limitations
• Audio Taper dB text is interpolated from Allen & Heath's published table, so under the Audio Taper law a dB label can differ slightly from the mixer's own display.
• No scene feedback. The mixer reports no scene number, so Last Scene is only the last scene this driver recalled.
• No soft key feedback. The protocol has none.
• No input processing. Gain, EQ and dynamics are not in the SQ MIDI protocol.
• Group masters, FX returns and send pans are in the protocol but not in these functions; reach them with Send MIDI Hex.
• One send mix at a time. The Send functions and variables address only the selected send mix.
• Inputs above Input Count are not read on connect or on Resync, so their variables stay at their defaults until the mixer reports a change.
• dB values depend on the Fader Law setting matching the mixer.
• No MAC Address variable. An offline activation code is locked to the RTI processor's own MAC address (not the mixer's). The driver does not publish it as a variable; TraceViewer shows it when a code does not fit.
• Licensing: without a license the driver runs a 30-minute trial, then refuses control functions while feedback goes on. An offline activation code works only on the processor whose MAC it was made for.
Support Contact
AchKayEm Solutions, LLC, dealer support:
• Email: support@achkayem-solutions.com
• Hours: Monday to Friday, 9 am to 5 pm Central Time
• Licenses and activation codes: https://vault.achkayem-solutions.com
Troubleshooting
Start with Link Diagnostics and Run Diagnostics: between them they show whether anything was sent, whether the mixer answered, and on which channel.
Connection State stays Disconnected; Status Message says Connecting... or that the connection failed
Cause and fix: Wrong address or port, or the mixer is not reachable from the processor. Check Utility > Network on the mixer.
Connected, but Responding stays off and Link Diagnostics shows other= climbing
Cause and fix: The MIDI Channel setting does not match Utility > General > MIDI on the mixer.
Connected, Responding off, nothing counted at all
Cause and fix: Something other than an SQ is answering on that address and port.
dB values a few dB off
Cause and fix: The Fader Law setting does not match the mixer's NRPN Fader Law.
Send rows blank
Cause and fix: They are blank until the selected send is read. Select the send mix again, or Resync.
Commands do nothing; Status Message says Control blocked
Cause and fix: The trial has ended, or the license does not fit this processor. Feedback keeps working.
A soft key does nothing at the mixer
Cause and fix: The key is above the mixer's count (an SQ-5 has 1-8), or has nothing assigned on the mixer.
When you contact support, include
• The driver version, the processor model and its firmware version.
• The mixer model and firmware version, its MIDI channel and NRPN Fader Law.
• Link Diagnostics and Status Message, exactly as shown.
• A TraceViewer log from the driver starting up to the failure.
Copyright and trademarks
This driver is developed by AchKayEm Solutions, LLC and is not endorsed by or affiliated with Allen & Heath Ltd or Remote Technologies Incorporated (RTI). "Allen & Heath", "SQ" and "RTI" are trademarks of their respective owners, used for identification only.
Copyright (c) 2026 AchKayEm Solutions, LLC. All rights reserved.
The driver runs a 30-minute trial each time it starts, until a license is applied. When the trial ends, control functions are refused (Status Message says "Control blocked") while feedback and the heartbeat go on.
To license it, paste a license key or an activation code from vault.achkayem-solutions.com into the License Key setting:
- License key (online): the processor activates against AchKayEm Vault over the internet once, then keeps a signed license and stays licensed across reboots with no network.
- Activation code (offline): for a processor with no internet route. An activation code is locked to one processor's MAC address, which has to be assigned in Vault before the code is made. When a code does not fit, TraceViewer shows the processor's MAC.
The Licensed, License Status, Licensed To and Trial Remaining variables show the license state.
Buy a license or an activation code at https://vault.achkayem-solutions.com.