Philips Dynalite DyNet Lighting

Two-way control of a Philips / Signify Dynalite lighting system over DyNet1, through a DyNet-over-IP gateway (DNG100BT or EnvisionGateway) or the DTK622 RS-232 gateway. Import the project's Logical.xml from System Builder and every area, channel and preset comes into Integration Designer named and tagged - no typing area, channel or preset numbers by hand.

Key Features

  • One-click project import: every area, channel and preset arrives with its real name from the Dynalite job, including areas kept inside System Builder folders
  • Named tags: drop a tag on a button and the command and its feedback are wired in one go
  • Two-way feedback: preset changes, channel levels and wall keypad presses on the bus show on every RTI panel
  • Events for every change: preset recalls, area and channel on/off and keypad presses fire RTI events, so a Dynalite keypad can run your own macros
  • Full lighting control: preset recall, area and channel on/off, channel levels for sliders, one-touch tap-to-toggle and hold-to-dim
  • On-screen keypads: keypad templates styled on Dynalite wall keypads in five finishes, with a Set up Keypads window that assigns rooms to each keypad and lights the active scene
  • Sample project included: a page for each room plus keypad pages, pointed at a live simulated Dynalite house so you can try it before you install
  • Moves between jobs: the imported project is stored in the driver and travels with Export / Import Configuration
  • Built for support: debug console and optional remote logging, off by default

Requirements

  • Philips / Signify Dynalite system on DyNet1
  • DNG100BT (TCP 9998), EnvisionGateway with the RTI port set to DyNet1 (TCP 50000), or DTK622 RS-232 gateway
  • RTI XP-class processor with Integration Designer 11.4 or later, or an ICP processor with Integration Designer 12
  • The project's Logical.xml exported from System Builder / Envision

How It Works

Export the logical data from System Builder and import it into the driver once. The driver builds every area, scene and channel control, each with live two-way feedback from the DyNet bus. Drag the tags onto your buttons, or start from the sample project and keypad pages, and wire keypad events to macros to bring the rest of the system into the lighting.

Philips Dynalite DyNet Lighting | Version 0.57

Introduction

Two-way control of a Philips / Signify Dynalite lighting system using the DyNet1 protocol, through a DyNet-over-IP gateway (DNG100BT or EnvisionGateway) or an RS-232 serial gateway (DTK622). Import the project's Logical.xml and every area, channel and preset is named and tagged automatically - no manual entry of area, channel or preset numbers. Every keypad press and preset change on the bus comes back to RTI as live feedback and as a named event.

Version History

| Version | Date | Changes | |---|---|---| | 0.57 | 3 Nov 2026 | Connection settings listed first in Driver Properties, descriptions on every setting, Debug Level off by default, and the driver is named Philips Dynalite DyNet Lighting. No change to tags, commands or feedback. | | 0.56 | 3 Nov 2026 | Import Dynalite Project now picks up areas kept inside System Builder folders (previously only areas at the top level of the file came through). System Builder's Toggle and Panic presets are skipped, as they cannot be recalled by number. Channels of type 1 are imported as dimmers. | | 0.55 | 29 Oct 2026 | The trial is timed from the processor's UTC clock, so a time zone change (for example converting an ID11 job for an ICP) no longer ends or extends it. Tested on an ICP-2 with Integration Designer 12. | | 0.54 | 24 Oct 2026 | Works in Integration Designer 12 as well as 11: file pickers, the keypad editor and Wire Keypad Text. | | 0.38 | 10 Oct 2026 | Virtual keypads (up to 10 keypads, 10 rooms each, five finishes), Set up Keypads, Wire Keypad Text and the keypad sample pages. | | 0.16 - 0.19 | Oct 2026 | Area level variable, Off buttons show the off state, slider commands for dimmer channels. | | 0.15 | 5 Oct 2026 | Import Dynalite Project opens a file browser; Export / Import Configuration; re-import warns which buttons would be affected; licence check copes with a slow start-up. | | 0.13 | 3 Sep 2026 | Select preset form (default) so relay channels respond; DyNet2 gateway port detection; every sent frame logged. | | 0.12 | 10 Aug 2026 | Events fire for every preset, area and channel change; channel levels read back on connect. |

Driver Features

  • Import the System Builder / Envision Logical.xml and every area, channel and preset is named and tagged automatically, including areas kept inside System Builder folders.
  • Two-way: preset changes, channel levels and keypad presses on the bus come back as live feedback and as named events.
  • Preset recall, area and channel on / off, channel levels for sliders, one-touch tap-to-toggle / hold-to-dim, up / down steps.
  • Virtual keypad templates styled on Dynalite wall keypads, with a keypad set-up window and a sample project.
  • DyNet-over-IP (DNG100BT, EnvisionGateway) or RS-232 (DTK622) gateways.
  • Debug console, optional remote logging, and a 120-minute trial.

Supported Devices

  • Gateways: Philips Dynalite DNG100BT (TCP 9998), EnvisionGateway / PDEG with the RTI port set to DyNet1 (TCP 50000), and the DTK622 RS-232 gateway.
  • Any Dynalite load controller or keypad on the DyNet1 network, controlled by logical area, channel and preset as defined in the project's Logical.xml.
  • Tested on a live site through an EnvisionGateway with DDRC420 relay and DDMC802 dimmer controllers.
  • RTI processors: XP-class processors with Integration Designer 11.4 or later, and ICP processors with Integration Designer 12 (tested on an ICP-2).

System Requirements

  • An RTI XP-class processor with Integration Designer 11.4 or later (driver runtime 24), or an ICP processor with Integration Designer 12.
  • A DyNet gateway: DNG100BT (TCP port 9998), EnvisionGateway (TCP port 50000, port type DyNet1), or DTK622 RS-232 gateway on a processor serial port.
  • The Logical.xml export of the Dynalite project from System Builder / Envision.
  • A fixed IP address (static or DHCP reservation) for an IP gateway.

Device Setup

The steps below (Parts 1 to 7) cover preparing the gateway, installing the driver, importing the Dynalite project, placing controls, one-touch dimming, keypads, events, and moving jobs.

Part 1 - Prepare the gateway

  • One driver instance talks to one gateway.
  • EnvisionGateway: in System Builder open the Ethernet Gateway, Ports, and set the port RTI connects to as DyNet1. Left on DyNet2, every reply is discarded and there is no feedback at all.
  • Serial (DTK622): three wires only. Processor RJ45 pin 6 (TX) to the gateway's receive terminal, pin 5 (RX) to its transmit terminal, pin 4 (GND) to its ground. Take the DTK622 terminal names from the Dynalite datasheet. Never leave out the ground wire. Default 9600 baud, 8 data bits, no parity, 1 stop bit.
  • Export the logical project from System Builder: File > Export > Logical Data..., choose Export all logical data and XML file, then OK. Leave Exclude hidden Areas, Channels and Presets ticked to keep hidden items out of RTI.

Part 2 - Install and connect

Add the driver to the project (it adds a source called Dynalite Lighting), open Driver Properties and set the Connection category:

  • Connection Type - DyNet over IP (Ethernet Gateway) or RS-232 Serial.
  • Gateway IP Address and Gateway TCP Port - IP only. 9998 for a DNG100BT, 50000 for an EnvisionGateway.
  • Serial Port and Baud Rate - serial only (default 9600).
  • Local Echo - leave off for most gateways. Tick it only if the gateway does not echo bus traffic back.
  • Device Label (optional) - a short name added to every log line, including remote-log lines. Blank uses the gateway IP or serial port. Set it whenever there is more than one gateway. Send the project. The Connection variable goes true when the gateway answers. If it does not answer, the driver retries about every 10 seconds and logs each attempt.

Part 3 - Import the Dynalite project

  1. Right-click the driver and choose Import Dynalite Project, then pick the Logical.xml. (Choosing the file in the Project Import setting also imports it straight away.)
  2. The driver builds, for every area: a named group, a scene button for every preset defined in the file, On / Off / Touch for the area, and for every channel On, Off and Touch, plus Level, Up and Down for dimmable channels - all with feedback. Channels marked Not Set in System Builder are skipped. Unnamed areas are named from their channels.
  3. If the new tags do not appear, tick or untick the setting Tick / untick to show new tags (Show Tags category at the top of Driver Properties). It does nothing except refresh the display. If they are still missing, save the project, close it and open it again. The project is stored inside the driver. Rebuild Tags from Stored Project regenerates every tag at any time without the original file. Re-importing a changed file that would remove a tag already placed on a page lists those buttons and asks first; answer No and nothing changes.

Part 4 - Place controls

Set the page (or layer) Source to Dynalite Lighting, open the Tag Browser, filter to an area (for example Area 23) and drag a tag onto a button. Tags marked M and V program the command and its feedback in one drop: the command goes in the button's Macro and the feedback in its Reversed slot, so the button changes colour when on. Off tags carry the Is Off variable, so an Off button lights while that area or channel is off.

Tag reference (N = area number, C = channel number, P = preset number from the file)

  • Area N Preset P - recall that preset. Lights while it is active. One tag per preset in the file.
  • Area N On / Area N Off - fade every channel in the area on / off. The On tag carries the area's on feedback: on = any preset other than the Off preset, or any channel above zero.
  • Area N Level - feedback only: the whole area's level in percent (its brightest channel). Use it on a text field under an area tile.
  • Area N Touch - tap toggles between the On preset and the Off preset; hold dims (see Part 5).
  • Area N Ch C On / Area N Ch C Off - channel on / off (relay and dimmable).
  • Area N Ch C Touch - tap toggles 100% / off; hold dims.
  • Area N Ch C Level - dimmable: 0-100 level command plus feedback (use on a slider). Relay: feedback only (0 or 100), no command.
  • Area N Ch C Up / Down - dimmable only: one 10% step from the current level at the Default Ramp Rate.

Show and hide graphics

A dropped tag only recolours a button. To show a layer or graphic while something is on, bind the On variable by hand to the layer's Visibility Variable or the button's Visible slot. For show-when-off, bind the Is Off variable instead: every area and every channel has an Is Off boolean (also on the Off tag) because RTI visibility has no NOT operator. Each area also has a Current Preset integer (no tag) for a text field.

Virtual keypads

The download includes SHPDynaliteKeypads.rtitemplate: on-screen keypads styled on Dynalite wall keypads, including Antumbra-style plates (white glass, magnesium, silver, brushed; 1, 2, 3, 4 and 6 buttons, plus a display version). Copy it into your Integration Designer Templates folder and run Options > Configure Templates. Drop a key on a button, then drop that preset's Area N Preset P tag on it: the key's indicator lights while the preset is active. The SampleFile.apex has keypad pages to copy from (see Part 5c).

Part 5 - One-touch dimming (Touch tags)

A Touch tag carries a 250 ms repeat rate, so the macro repeats every 250 ms while the button is held. The driver counts the repeats:

  • Tap (released before 1 second) - area: toggles On preset / Off preset; channel: toggles 100% / off. A tap acts about one repeat tick after release, while the driver confirms no more repeats are coming.
  • Hold (1 second or more) - ramps up if below 50%, down if at 50% or above (an area uses its brightest channel). A full ramp takes the Hold-Ramp Time (default 8 s). Release stops at the current level.
  • Only one Touch button is tracked at a time - pressing another finishes the first one's action.
  • Touch Repeat Rate (ms) must match the repeat rate on the Touch tags (250). Touch Hold Threshold (ms) sets how long counts as a hold (default 1000).
  • For an instant response with no tap delay, use the One Touch functions: Ramp Up or Ramp Down on press, Ramp Stop on release.

Part 5b - Keypads with a Home room menu (layer switching)

Up to 10 numbered keypads, each with up to 10 rooms. Each iPad or remote keeps its own place on each keypad. A keypad starts on Home, where the touch screen shows a menu of room names; tapping one opens that room. In a room the screen shows the room name and level with a Back button under it, and the six keys recall that room's presets and light on the active one (white keys glow neon blue).

  • Easiest: right-click the driver > Set up Keypads... (or tick Edit this keypad... in Driver Properties > Keypad N; it unticks itself) - pick a keypad, name it, add its rooms from your Dynalite areas or a layer-only room such as Pool, put them in Home-menu order, set the presets keys 1-6 recall, and click OK.
  • Or by hand in Driver Properties > Keypad N: a Name, the Rooms (up to 10, separated by ; - Name=area or just a name, e.g. Living Room=50; Masterbed=23; Pool) and the Keys (presets for keys 1-6, default 1,2,3,4,5,6).
  • More than 6 rooms: the Home menu shows 5 rooms with Next in the sixth place, then the next 5 with Next or Prev.
  • A layer-only room (e.g. Pool) just opens - its keys stay blank and you put its controls on its layer.
  • Tags and commands are numbered: Keypad N Room R (Home tile, command Keypad 1 Room 2: Show Lounge), Keypad N Home 1 / Home 2 (Next / Prev), Keypad N Room R Key J (Keypad 1 Room 2 Key 1: Lounge - High, lit while that preset is active) and Keypad N Back (also hides itself on Home).
  • Text tokens: Keypad N Room Name (keypad name on Home, room name in a room) and Keypad N Level. For room names: Keypad N Room R Name (the room on Home tile R and its room title, blank if unused). Room keys are plain text - change a key's text when you change its command. After merging a keypad page, right-click the driver > Wire Keypad Text (it also runs when you OK Set up Keypads) so the room names are bound in your project.
  • On a page whose source is not Dynalite (Home, a TV, another driver): put the keypad viewport on its own layer (e.g. Lighting) and set that layer's Source to Dynalite Lighting. The keypad layers inside use Use Default Source, so they take Dynalite from that layer. If a copied keypad layer shows its source as Unknown, open its Layer Properties and press OK.
  • Layer switching (per panel): Keypad N Home, Keypad N Home 1 / Home 2, Keypad N Room R (Keypad 1 Room 2: Lounge Showing) and Keypad N In A Room are true only on the panel where that page is open.
  • Events: Keypad N: Any Room Shown, Keypad N Room R: <room> Shown, Keypad N: Back to Home.
  • After updating from an older version, run Rebuild Tags from Stored Project once so the names are stored.

Part 5c - The sample keypad pages and the live demo

RULE ONE: the SampleFile.apex is connected to the SHP live demo server (a simulated Dynalite house) so you can try the keypads with real feedback. For a real job set Gateway IP Address and Gateway TCP Port to your own gateway first.

  • 50 keypad pages: Keypad 1-10 in White, Black, Magnesium, Silver and Brushed, fully wired. Each shows the keypad at three sizes - Large 592 x 977, Medium 528 x 828, Small 480 x 768 (landscape). The left column jumps between keypads, the top row between finishes.
  • To use one: Page > Merge Pages, pick the page for your keypad number and finish, keep one size and delete the others and the pickers, then run Set up Keypads... for that keypad. Layers are named Keypad 1 Room 2 (Large) with no room name, so add your own.
  • The live demo banner (layer Live Demo Status) shows how many integrators are connected and warns when two or more share the demo house. Delete that layer in a real project.

Part 6 - Events and automation

The driver signals an event whenever something changes on the Dynalite network - from a wall panel, a sensor, another system or RTI itself. Wire a macro to an event under Driver Events. Events fire after the matching variables are updated, so a macro can read them straight away.

  • Per area: Preset Changed (any) AREA{N}PRESET; Area On AREA{N}ON; Area Off AREA{N}OFF; one per preset named as in System Builder (e.g. Living: Movie Recalled) AREA{N}PRESET{P}.
  • Per channel: On AREA{N}CH{C}ON and Off AREA{N}CH{C}OFF - only on crossing on/off, never while dimming.
  • Driver-wide: CONNECTED, DISCONNECTED, TRIALWARNING, TRIALEXPIRED, and (when Enable Whole-System Events is ticked) PRESETCHANGED and CHANNELCHANGED. The Last Preset / Last Channel variables are always live, whether or not that is ticked.

Events settings

  • Enable Events - master switch (on).
  • Enable Channel On/Off Events - per-channel events (on). Turn off on large jobs if unused.
  • Enable Whole-System Events - the two system-wide events (off).
  • Preset Event Trigger - On change only (default) or Every recall. Status reports and polls never count as a recall. On a gateway that echoes traffic, an RTI recall may fire twice in Every recall mode.
  • No events at start-up - the driver reads every area when it connects, and that first reading only sets the variables. Events start from the next real change, so a reboot or project download never re-runs a macro. To prove a macro is wired, type event AREA17PRESET2 (your own numbers) in the debug console.

Lighting Defaults

  • Default Fade (1 s) and Default Ramp Rate (2 s).
  • Hold-Ramp Time (8 s), Touch Hold Threshold (1000 ms), Touch Repeat Rate (250 ms).
  • On Preset Number (1) and Off Preset Number (4) - used by taps and one-touch On/Off; the Off preset is also what counts as an area being off.
  • Preset Command Format - Select (matches Dynalite keypads) is the default and the form wall keypads send; some relay modules (e.g. DDRC420) respond only to it. Recall (channel-scoped 0x6B) is the alternative.
  • Area 0 = All Areas (broadcast) - on by default: an All Off keypad that sends to area 0 updates every imported area. Untick only if a job uses area 0 as a real area.
  • Feedback Poll (0 = rely on bus reports, recommended) and Poll Command Spacing (100 ms).
  • Request Channel Levels on Connect (on) - reads every channel's level once after connecting, paced.
  • Auto-refresh Levels on Preset Change (off), Refresh Start Delay (2000 ms - set at or above your longest fade) and Refresh Request Spacing (100 ms).

Commands for macros

  • Lighting Commands - Recall Preset, Recall Preset (Area Range), Set Channel to Preset, Ramp Channel to Level, Stop Channel Fade (Channel 0 = whole area), Area On, Area Off.
  • One Touch - Area On / Off (preset), Area Ramp Up / Down (hold), Area Ramp Stop (release), and the same for a channel.
  • Status Requests - Request Area Preset, Request Channel Level, Refresh Area Levels (paced), Request All Status.
  • Advanced - Send DyNet Message (hex): type the 7 message bytes, e.g. 1C 01 03 6B 02 32 FF; the checksum is added for you.
  • Diagnostics - Reconnect, Remote Logging On, Remote Logging Off.

Part 7 - Moving jobs and updating

  • Export Configuration (driver menu) saves every setting plus the stored project to a .driverconfig file. Import Configuration on the next job restores the settings and all the named tags with no Logical.xml. The licence key is never exported.
  • After updating the driver, SAVE, CLOSE AND REOPEN the project. The tags are rebuilt from the stored project when it opens; until then the per-area buttons do nothing. If tags are still missing, run Rebuild Tags from Stored Project.
  • More than one gateway: one driver instance per gateway, each with its own Device Label and its own Debug Console Port. One licence key covers every instance on the same processor.
  • Do not edit Area Model (do not edit) in the Stored Project category - it lets the driver restore its model after an update.

Troubleshooting

  • No feedback at all on an EnvisionGateway, and TraceView shows Receiving DyNet2 frames (0xAC) - set the gateway port type to DyNet1.
  • A relay ignores RTI but works from the keypad - set Preset Command Format to Select.
  • A channel never reports its level - tick Auto-refresh Levels on Preset Change or set a Feedback Poll.
  • Buttons dead after a driver update - save, close and reopen the project, then send it.
  • Tags missing after an import - tick / untick the Show Tags setting; else save, close and reopen.
  • Everything stopped after about two hours - the trial has ended. TraceView shows Command blocked - trial expired (once a minute). Enter a key; feedback keeps working meanwhile.
  • Debug console will not connect - another driver holds the port (TraceView: WinSockets: Bind failed). Change Debug Console Port.
  • A level 1% different from System Builder is rounding, not a fault.
  • To diagnose: set Debug Level to Verbose, use the debug console and, if we ask, remote logging.

Diagnostics

Debug console: telnet to the processor on the Debug Console Port (default 12574; 0 disables). Commands: status, areas, events, event <TAG>, preset A P, on A C, off A C, level A C V, req A, refresh A, send <hex>, rxdump, rxdump off, mac, licence, rlog, rlog test, raw b0 .. b6.

Remote logging: off by default; switch it with the Remote Logging On / Off functions when Smart Home Programming support asks. If the site's DNS cannot resolve shpdrivers.services, set Log Server Host to 209.38.27.58.

Driver Configuration

Show Tags

  • Tick / untick to show new tags - default false - This box does nothing except refresh the display. After importing a project or rebuilding tags, tick or untick it to make the new tags appear in the Tag Browser and macro tree.

Project Import

  • Dynalite Logical.xml - Browse to the Logical.xml exported from System Builder / Envision. On selection (or via the right-click 'Import Dynalite Project' menu) every area, channel and preset is named and tagged automatically.

Connection

  • Connection Type - default IP - How the processor reaches the Dynalite network.
  • Gateway IP Address - IP transport only. Address of the DyNet-over-IP gateway (DNG / EnvisionGateway).
  • Gateway TCP Port - default 9998 - IP transport only. 9998 for DNG100BT, 50000 for EnvisionGateway.
  • Serial Port - Serial transport only. Processor serial port wired to the DyNet gateway (DTK622).
  • Baud Rate - default 9600 - Serial transport only.
  • Local Echo - default false - Enable if the gateway does NOT echo bus traffic back - keeps two-way feedback working.
  • Device Label (optional) - Tags this driver's log lines. Blank uses the gateway IP or serial port.

Lighting Defaults

  • Default Fade (seconds) - default 1 - Fade time used for preset recalls and area/channel on/off when none is specified.
  • Default Ramp Rate (seconds) - default 2 - Ramp rate used for channel level / dim up / dim down.
  • Hold-Ramp Time (seconds) - default 8 - Travel time for the one-touch hold-ramp (Ramp Up / Ramp Down). Holding fades from one end to the other over this time; release stops at the current level. Longer = finer control.
  • Touch Hold Threshold (ms) - default 1000 - How long a Touch button must be held before it starts dimming. Below this it counts as a tap and toggles on/off instead.
  • Touch Repeat Rate (ms) - default 250 - Must match the repeat rate on the Touch tags (default 250). The driver counts button repeats to tell a hold from a tap, so changing this alone will misread holds.
  • On Preset Number - default 1 - Preset used by the one-touch 'On' (Area On (preset)). Dynalite convention: 1.
  • Off Preset Number - default 4 - Preset treated as 'off' for an area, and used by the one-touch 'Off' (Dynalite convention: 4).
  • Preset Command Format - default Select (matches Dynalite keypads)
  • Area 0 = All Areas (broadcast) - default true - In DyNet, area 0 means 'every area'. An All Off keypad button sends a preset to area 0. With this ticked the driver applies that preset to every imported area, so feedback and Area Off events follow the lights. Untick only if a job genuinely uses area 0 as a normal area, or to avoid the burst of updates an All Off causes on a very large system.
  • Feedback Poll (seconds) - default 0 - Periodically re-query each area's preset. 0 = rely on bus reports only (recommended).
  • Poll Command Spacing (ms) - default 100 - Delay between each area's request when the feedback poll runs (and during the one-time seed at connect), so the poll never fires a burst of requests back-to-back. 100 ms recommended.
  • Request Channel Levels on Connect - default true - After connecting, read back every channel's level once so the panel shows what the lights are actually doing rather than starting at zero. Runs after the area presets have been read, one request at a time at the Refresh Request Spacing, so it never floods the bus. Untick on a very large system if you would rather the startup traffic was lower.
  • Auto-refresh Levels on Preset Change - default false - When an area's preset changes (from a wall panel or the driver), automatically re-request that area's channel levels so feedback stays accurate. Requests are paced (see below) so this never blasts the bus or lags the processor on large jobs.
  • Refresh Start Delay (ms) - default 2000 - How long to wait after a preset change before requesting channel levels, so the channels finish fading first (reading a level mid-fade returns a false value). Set at or above your longest scene fade time.
  • Refresh Request Spacing (ms) - default 100 - Delay between each channel-level request during an auto-refresh. 100 ms recommended - raise it on very large jobs, lower it for snappier feedback.

Events

  • Enable Events - default true - Fire an RTI event whenever an area changes preset, turns on or off, or a channel turns on or off - so a Dynalite keypad press can trigger anything else in the project (a scene, another driver, an HVAC command). Turn off to stop the driver signalling events entirely.
  • Enable Channel On/Off Events - default true - Include the per-channel 'Ch N On' / 'Ch N Off' events. These only fire when a channel crosses on/off (never while dimming), but on a large job they are the bulk of the event tags - turn off if you only wire preset events.
  • Enable Whole-System Events - default false - Also fire a single 'Any Preset Changed' / 'Any Channel On or Off' event for the whole system, (the Last Event system variables are always kept up to date either way). Use this instead of wiring hundreds of individual tags when one macro can branch on the values.
  • Preset Event Trigger - default 0 - When to fire preset events. 'On change only' ignores a preset being recalled again while it is already active. 'Every recall' fires on every press, which suits a keypad button that re-sends a command each time (nudging an air conditioner, re-asserting a scene). Status reports and feedback polls never count as a recall, so this is safe to use with a feedback poll running. Note that on a gateway that echoes traffic back, an RTI-initiated recall may fire twice in this mode - once optimistically and once on the echo.

Keypad N (N = 1-10, same for each)

  • Edit this keypad... (tick to open the setup window) - default false - Opens the keypad setup window on Keypad 1. Unticks itself when the window closes.
  • Keypad 1 Name - Name shown for this keypad (variable Keypad 1 Name). Blank = Keypad 1.
  • Keypad 1 Rooms - Up to 10, separated by ; - Name=area or Name only, e.g. Living Room=50; Pool
  • Keypad 1 Keys (preset numbers) - default 1,2,3,4,5,6 - In a room, keys 1-6 recall these presets, comma separated.

Licence

  • Licence Key - Per-processor licence key. Leave blank for the trial. Get a key from Smart Home Programming using the MAC shown in System Variables.

Licensing

  • Trial: 120 minutes from the first load on a processor. It is remembered - reloading the driver, re-downloading the project or rebooting does not restart it. A Trial Warning event fires 5 minutes before it ends.
  • The trial is timed from the processor's UTC clock, so a time zone change - for example when an ID11 job is converted for an ICP - does not shorten or lengthen it.
  • When the trial ends without a key, lighting commands stop but feedback keeps working.
  • Keys are per processor. The processor MAC is in the MAC For Key system variable (or type mac in the debug console). Buy a key at smarthomeprogramming.com.au/store/ - AUD $189 ex GST.
  • Paste the key into Licence Key. Spaces, line breaks and case are ignored.

Functions

Lighting Commands

  • Recall Preset - Area, Preset, Fade (seconds)
  • Recall Preset (Area Range) - Area From, Area To, Preset, Fade (seconds)
  • Set Channel to Preset - Area, Channel, Preset
  • Ramp Channel to Level - Area, Channel, Level (percent), Rate (seconds)
  • Stop Channel Fade - Area, Channel (0 = whole area)
  • Area On - Area, Fade (seconds)
  • Area Off - Area, Fade (seconds)

One Touch

  • Area On (preset) - Area
  • Area Off (preset) - Area
  • Area Ramp Up (hold) - Area
  • Area Ramp Down (hold) - Area
  • Area Ramp Stop (release) - Area
  • Channel On - Area, Channel
  • Channel Off - Area, Channel
  • Channel Ramp Up (hold) - Area, Channel
  • Channel Ramp Down (hold) - Area, Channel
  • Channel Ramp Stop (release) - Area, Channel

Status Requests

  • Request Area Preset - Area
  • Request Channel Level - Area, Channel
  • Refresh Area Levels (paced) - Area
  • Request All Status

Advanced

  • Send DyNet Message (hex) - Hex Bytes

Diagnostics

  • Reconnect
  • Remote Logging On
  • Remote Logging Off

Keypads (generic)

  • Keypad: Show Home Page - Keypad, Page
  • Keypad: Back to Home - Keypad
  • Keypad: Show Room (slot) - Keypad, Room
  • Keypad: Show Room (area number) - Keypad, Area

Keypad N (N = 1-10, same for each)

  • Keypad 1: Back to Home
  • Keypad N: Show Home Page N (N = 1-1)
  • Keypad N Room N: Show Room N (N = 1-1)

Variables

Status

  • Connection - boolean
  • Connection State - integer (0 Disconnected, 1 Connected)
  • Connection State - Connected / Connection State - Disconnected - booleans
  • Status Text - string
  • Driver Version - string
  • Areas Imported - integer

Last Event

  • Last Preset Area - integer
  • Last Preset Number - integer
  • Last Channel Area - integer
  • Last Channel Number - integer
  • Last Channel Level - integer
  • Last Channel On - boolean

Licence

  • Licence Valid - boolean
  • Licence Status - string
  • Trial Active - boolean
  • Trial Expired - boolean
  • Trial Time Remaining - string
  • MAC For Key - string
  • License Status - string: Licensed, Trial or Unlicensed
  • License Status - Licensed / - Trial / - Unlicensed - one boolean per state
  • License Trial Remaining - string

Keypad N (N = 1-10, same for each)

  • Keypad 1: Home Showing (any page) - boolean
  • Keypad N: Home Page N Showing (N = 1-1) - boolean
  • Keypad N Room N: Room N Showing (N = 1-1) - boolean
  • Keypad 1: A Room Is Showing - boolean
  • Keypad 1: Name - string
  • Keypad 1: Page Name - string
  • Keypad 1: Screen Title - string
  • Keypad 1: Room Level - string

Keypad N: Button names (N = 1-10, same for each)

  • Keypad N Room N Name (N = 1-1) - string

    Autoprogramming Support

Every area, channel and preset gets static, numbered tags (Area N ..., see Part 4) generated when the project is imported. Set a page or layer Source to Dynalite Lighting and drop a tag on a button: tags that carry both a command and a variable program the button's Macro and its Reversed (feedback) slot in one drop. The numbers stay the same when areas are renamed in System Builder, so placed buttons keep working after a re-import. The keypad tags (Keypad K ...) are fixed and do not change with the project.

Limitations

  • DyNet1 only (an EnvisionGateway port must be set to DyNet1).
  • Logical area / channel / preset control only - no physical box addressing and no joins.
  • No named HVAC, temperature, motion, task, keypad LED or panic commands - use Send DyNet Message (hex).
  • A single Dynalite Lighting hub source rather than one source per room.
  • Imports Logical.xml only (not load-controller CSV exports).
  • DyNet2 is not supported; the driver detects a DyNet2 port and says so in TraceView.
  • A relay controller that never reports its state can show stale feedback until the channel is next read.
  • Levels can differ from System Builder by 1% because of rounding.

Support Contact

Smart Home Programming

david@smarthomeprogramming.com.au

smarthomeprogramming.com.au

Phone: 0401 190 122

This driver requires a licence key tied to your RTI processor's MAC address.

  • Trial: 120-minute fully functional trial - no key required
  • Purchase: Visit https://smarthomeprogramming.com.au/store/ to buy a licence
  • Licence is per-processor - one key per processor