MyAir HVAC

Full two-way RTI control of Advantage Air MyAir5 and MyPlace ducted air-conditioning. The driver talks to the MyAir/MyPlace tablet directly over the local network - no cloud account and no internet connection needed.

Key Features

  • Head unit control: power, mode (Cool / Heat / Vent / Dry), fan speed and setpoint, with live feedback including filter, fault, MyAuto and Quiet Night status.
  • Every zone: open and close, target temperature and damper position per zone, with measured temperature, wireless sensor signal and motion feedback.
  • Zones found for you: Driver Utilities > Discover MyAir Zones reads the tablet and fills in the zone count, every zone name and which zones have a temperature sensor.
  • Multi-aircon systems: add the driver once per A/C unit (East, West...). Each instance owns its own zones and can carry a Device Label so the units are told apart in the log.
  • Climate web page: a ready-made dark page served by the processor - the whole unit at a glance with a temperature dial per zone. An optional Show Both Aircons page puts every unit in one web object with a toggle between them. Pages fill whatever web-object size you draw.
  • Real schedules: the driver's own clock-time scheduler turns the system on or off at a time of day on chosen days, with mode, temperature, fan and per-zone open / close and target temperature. Unlike the MyAir app's hours-from-now timer.
  • Tag wiring both ways: place Aircon and Zone sources and drop standard tags, or type numbered Zone N tags straight onto any button.
  • Built for support: debug console, per-unit log tagging and optional remote logging so a fault can be diagnosed without attending site.

Requirements

  • An Advantage Air MyAir5 or MyPlace system on the same local network as the RTI processor
  • The MyAir/MyPlace tablet's IP address - set a DHCP reservation so it does not change
  • RTI processor at runtime 24 or later, Integration Designer 11.2 or later for the Discover utility
  • For the web page: panels on a network that can reach the processor

How It Works

The driver polls the MyAir tablet's local API for the full system state and sends each change straight back to it. Commands update the panel instantly and the next poll confirms what the system actually did. Schedules run on the processor's own clock, so they keep working whether or not a panel is open, and they survive a reboot.

MyAir HVAC | Version 1.19

Introduction & Manufacturer Profile

Advantage Air is an Australian maker of ducted air-conditioning zone control. Its MyAir5 and MyPlace systems run from a wall tablet that controls the A/C unit and opens, closes and sets the temperature of each zone (room).

This driver gives RTI two-way control of a MyAir5 or MyPlace system over the local network. It controls the A/C head unit (power, mode, fan speed, setpoint, MyZone, on/off timer) and every zone (open/close, setpoint, damper opening), and reports full feedback: temperatures, filter and fault status, zone sensor signal and motion. It also hosts a Climate web page on the processor for use as an RTI Web Object, and has its own clock-time scheduler.

Important Note

  • Local network only. The driver talks to the MyAir/MyPlace tablet over HTTP on port 2025 (the tablet's local API). No Advantage Air cloud account is used. Give the tablet a DHCP reservation so its IP never changes.
  • One driver instance per A/C unit. A tablet that runs two A/C units (for example East = ac1, West = ac2) needs the driver added twice, both with the same IP and a different A/C Unit Number. Give each instance a different Web Server Port (for example 9062 and 9063) and a different Debug Port (for example 12527 and 12528).
  • External service - remote logging (off by default). When Enable Remote Logging is on (or the Remote Logging On function is run), the driver sends its log lines over HTTPS (TLS, port 443) to shpdrivers.services, run by Smart Home Programming and Automation, so we can diagnose a fault remotely. It sends the driver name and A/C unit (myair-ac1, myair-ac2), the driver version, the processor MAC address and the log lines themselves. Nothing else is sent, and nothing at all is sent while it is off. The driver works exactly the same without it.

Version History

  • 1.19 - Climate web pages now fill any web-object shape instead of showing dark bars at the sides (the layout grows into the spare space); at the standard sizes (1630x653 Climate page, 1630x1306 aircon switcher) they look exactly as before. Re-fits on rotation.
  • 1.18 - Official publisher standard: Connection State variable (Disconnected / Connected) with Connected and Disconnected booleans; License Status variable (Licensed / Trial / Unlicensed) with booleans; Device Label setting and per-unit log tagging (two instances on one processor are now told apart in TraceView); Remote Logging On / Off / Toggle functions; licence key whitespace is now ignored and the key is re-checked after start-up; Debug and Remote Logging settings hidden, debug off by default; help supplied as instructions.md.
  • 1.17 - Climate web page: "now" label removed, larger zone temperatures, schedule time shown under the Schedule heading.
  • 1.16 - Show Both Aircons page: switching between units no longer jumps back when a slow reply arrives.
  • 1.15 - Show Both Aircons page: fixed a blank page when loaded from the second unit's port; remote log split per A/C unit.
  • 1.14 - Show Both Aircons: one web object showing one A/C unit at a time with a toggle between units.
  • 1.13 - Climate web page scales to fit the web object.
  • 1.12 - Schedules can open or close individual zones and set their temperatures.
  • 1.11 - Interim build towards per-zone schedules.
  • 1.10 - Climate web page rebuilt: whole A/C unit on one page with a card per zone.
  • 1.9 - Clock-time recurring schedules (up to 8), edited from the web page.
  • 1.8 - Processor-hosted web page (thermostat dial).
  • 1.7 - Filter, fault, MyAuto, Quiet Night, zone signal and motion feedback; full tag reference.
  • 1.6 - Driver Version and zone selection variables no longer read empty.
  • 1.5 - Zone tags rebuilt (zone sources plus numbered Zone N tags); zones created by Discover; multi-A/C support; polling stall fix.
  • 1.4 - Licensing and Discover MyAir Zones.
  • 1.3 - Tag rebuild, debug console and remote logging.
  • 1.0 - 1.2 - Initial releases: A/C head unit and zone control over the local MyAir API.

Driver Features

  • A/C head unit: power on / off / toggle; mode Heat, Cool, Vent, Dry; fan Low, Medium, High, Auto; setpoint (set, up, down); MyZone; on and off countdown timers.
  • Zones (up to 10 per A/C unit): open, close, toggle; setpoint (set, up, down); damper opening; select (one zone at a time, for layer visibility).
  • Feedback: power, mode and fan text plus a boolean per state; setpoint; per-zone open/closed, setpoint, damper, measured temperature, fault, sensor signal and motion; filter-clean, A/C fault and error code; MyAuto, Quiet Night and climate-control status; firmware-update flag.
  • Polling: the driver reads the whole system (getSystemData) every Poll Interval seconds (default 5, range 5-120). Your own commands update the variables at once and are not overwritten by the next poll; changes made at the tablet or the MyAir app show on the next poll.
  • Connection State: Disconnected until the first good reply from the tablet, Connected after it, and back to Disconnected when a poll fails.
  • Climate web page hosted on the processor (no cloud): power, mode, fan, timer, a temperature dial for the unit and a card per zone. Optional Show Both Aircons page.
  • Schedules: up to 8 clock-time schedules (time, days, on/off, mode, temperature, fan, and per-zone open/close/temperature), stored on the processor and surviving reboots.
  • Events for power, connection, filter, faults, zone open/close/motion/fault, schedule runs and licence trial.

Supported Devices

  • Advantage Air MyAir5 and MyPlace systems with the wall tablet on the local network (local API on port 2025).
  • Up to 8 A/C units per tablet (one driver instance each), up to 10 zones per A/C unit.
  • Developed and tested against a MyPlace tablet controlling two A/C units.

System Requirements & Prerequisites

  • Integration Designer - 11.0 or above (11.2 or above for the Discover MyAir Zones utility)
  • RTI processor - XP-8 class (XP-3 / XP-6 / XP-6s / XP-8 / XP-8s / XP-8v)
  • Processor script runtime - 24 or above
  • Network - the processor must reach the tablet on TCP 2025. Panels showing the web page must reach the processor on the Web Server Port.

Device Setup

  1. On the router, give the MyAir/MyPlace tablet a DHCP reservation so its IP address never changes.
  2. Add the driver to the project and enter the tablet's IP Address and the A/C Unit Number (1 for the first unit).
  3. Open Driver Properties > Driver Utilities > Discover MyAir Zones. It reads the tablet, sets Zone Count, fills in each zone's name and temperature-sensor flag, and lists every A/C unit found. Run it again whenever the MyAir zone layout changes.
  4. For a second A/C unit, add the driver again with the same IP, A/C Unit Number 2, a different Web Server Port and a different Debug Port, then run Discover on that instance too.
  5. Add an Aircon source to the HVAC page for the head-unit controls, and a Zone source to each room for that zone's controls. Drop the tags listed under Autoprogramming Support onto buttons.
  6. Send the project to the processor. Connection State should read Connected.

Driver Configuration

Connection Settings

  • IP Address - default 192.168.1.100 - IP address of your MyAir/MyPlace tablet. For a multi-aircon system, every instance uses the SAME IP - they differ only by A/C Unit Number.
  • Port - default 2025 - API port (default 2025).
  • A/C Unit Number - default 1 - Which A/C unit this instance controls (1 for ac1, 2 for ac2, ...). Add the driver once per A/C unit. Run Discover after setting this.
  • Poll Interval (seconds) - default 5 - How often to poll for status updates (5-120 seconds).
  • Device Label - Optional name for this A/C unit in the log (e.g. East). Blank = ac1, ac2... Useful when two instances run on one processor.

HVAC Modes

  • Heat Mode - default true - Does your A/C support Heat Mode
  • Cool Mode - default true - Does your A/C support Cool Mode
  • Vent/Fan Mode - default true - Does your A/C support Vent/Fan Mode
  • Dry Mode - default true - Does your A/C support Dry Mode

Fan Speeds

  • Auto Fan Speed - default true - Does your A/C support Auto Fan Speed

Temperature Settings

  • Minimum Setpoint - default 16 - Minimum temperature setpoint (Celsius)
  • Maximum Setpoint - default 32 - Maximum temperature setpoint (Celsius)

Zones

  • Zone Count - default 0 - Number of zones on this A/C unit. Set automatically by Discover MyAir Zones; only this many zone slots below are shown.

Zone N Settings (N = 1-10, same for each)

  • Zone 1 Name - default Zone 1 - Friendly name for this zone. Set by Discover; used on the zone source + picker labels.
  • Zone 1 Temp Control - default true - Zone has a temperature sensor/control. Set by Discover.

Advanced Features

  • Fresh Air Support - default false - Does your system support Fresh Air control

Schedules

  • Enable Schedules - default true - Master switch for the built-in scheduler. Turn this off to suspend all schedules without deleting them. Individual schedules are edited on the Web Object schedule page (tap the room name, then Schedule).
  • Schedule Time Offset (min) - default 0 - Only change if scheduled times fire at the wrong hour. Minutes added to the processor clock (e.g. 600 if the clock reads UTC and you are UTC+10). Leave at 0 normally.

Web Object

  • Enable Web Object - default true - Hosts an arc-dial thermostat page on the processor for use as an RTI Web Object. Covers the A/C head and every zone (pick via the name at top-left, or open a zone directly with ?unit=N).
  • Web Server Port - default 9062 - TCP port for the web page. With TWO driver instances on one processor give each a DIFFERENT port (e.g. 9062 and 9063). Open http://[processor-ip]:[port]/ in a browser.
  • Show Both Aircons (one web object) - Optional. To show BOTH A/C units in ONE web object with a toggle to switch between them, list each unit as Name:WebPort separated by commas (e.g. Aircon 1:9062,Aircon 2:9063 - use your own names) and point the web object at http://[processor-ip]:9062/aircons (size 1630x1306). Set the same value on both instances. Leave blank for a single-unit page.

Licence

  • Licence Key - Paste the licence key supplied by Smart Home Programming for this processor. Without a valid key the driver runs in 120-minute trial mode and then stops sending commands.

Debug Console (hidden - developer use)

  • Debug Port - default 12527 - TCP port for the telnet debug console (status, zones, poll, sched now, rlog and more). Set to 0 to disable. Two instances on one processor need different ports.
  • Debug Level - default 0 - Off (errors only) - How much the driver logs to TraceView. Raise only while troubleshooting.

Remote Logging (Development) (hidden - developer use)

  • Enable Remote Logging - default false - Streams the driver log to Smart Home Programming for remote diagnosis (see Important Note). Can also be switched at run time with the Remote Logging On / Off / Toggle functions.
  • Remote Log Host - default shpdrivers.services - Leave as default. If the site's DNS cannot resolve it, enter 209.38.27.58.
  • Remote Log Port - default 443 - 443 = HTTPS.

Licensing

  • The driver needs one licence key per RTI processor. Buy it at https://shpdrivers.services/store/ and paste it into Licence Key (Driver Properties > Licence). Leading or trailing spaces in a pasted key are ignored.
  • The key is tied to the processor's MAC address, shown in the MAC For Key variable.
  • Trial: without a valid key the driver runs a 120-minute trial with everything working. The trial restarts when the driver reloads.
  • Unlicensed: after the trial, commands from RTI stop (and each blocked command is logged). Polling and feedback keep running, so the panel still shows the real state.
  • License Status reads Licensed, Trial or Unlicensed, with a boolean for each (License Status - Licensed / Trial / Unlicensed) and License State as an integer (0 Unlicensed, 1 Trial, 2 Licensed). Trial Time Remaining shows the minutes left. The older Licence Valid and Licence Status variables are still published.
  • The SampleFile.apex needs a licence key or the trial to run.

Functions

A/C System Control

  • Power On
  • Power Off
  • Power Toggle
  • Mode Heat
  • Mode Cool
  • Mode Vent
  • Mode Dry
  • Set Temperature - setpoint
  • Temperature Up
  • Temperature Down
  • Fan Low
  • Fan Medium
  • Fan High
  • Fan Auto
  • Set MyZone - zone
  • Timer Off (minutes) - minutes
  • Timer On (minutes) - minutes
  • Refresh Status

Zone Control (add a Zone source)

  • Open - zone (10 choices)
  • Close - zone (10 choices)
  • Toggle - zone (10 choices)
  • Temp Up - zone (10 choices)
  • Temp Down - zone (10 choices)
  • Set Temp - zone (10 choices), setpoint
  • Set Damper - zone (10 choices), percentage

{ZoneNName} (per-number) (N = 1-10, same for each)

  • {Zone1Name} - Open
  • {Zone1Name} - Close
  • {Zone1Name} - Toggle
  • {Zone1Name} - Temp Up
  • {Zone1Name} - Temp Down
  • {Zone1Name} - Set Temp - setpoint
  • {Zone1Name} - Set Damper - percentage

Zone Select

  • Select (pick zone) - zone (10 choices)
  • Select {ZoneNName} (N = 1-10)

Schedules

  • Schedules Master On
  • Schedules Master Off
  • Enable Schedule Slot - slot
  • Disable Schedule Slot - slot
  • Run Schedule Now - slot

Diagnostics

  • Print Tag Reference
  • Reconnect / Reload Config
  • Remote Logging On
  • Remote Logging Off
  • Remote Logging Toggle

Variables

Connection

  • Connection Status - boolean
  • Connection State - integer (0=Disconnected, 1=Connected)
  • Connection State - Connected - boolean
  • Connection State - Disconnected - boolean

Licence

  • License Status - string
  • License State - integer (0=Unlicensed, 1=Trial, 2=Licensed)
  • License Status - Licensed - boolean
  • License Status - Trial - boolean
  • License Status - Unlicensed - boolean
  • Licence Valid - boolean
  • Licence Status - string
  • Trial Active - boolean
  • Trial Expired - boolean
  • Trial Time Remaining - string
  • MAC For Key - string
  • Driver Version - string

Schedule

  • Schedules Enabled - boolean
  • Enabled Schedule Count - integer
  • Next Schedule - string
  • Last Triggered - string

A/C System Status

  • System Name - string
  • System Setpoint - integer
  • Power On - boolean
  • Power Off - boolean
  • Current Mode - string
  • Mode Cool - boolean
  • Mode Heat - boolean
  • Mode Vent - boolean
  • Mode Dry - boolean
  • Fan State - string
  • Fan Low - boolean
  • Fan Medium - boolean
  • Fan High - boolean
  • Fan Auto - boolean
  • Fresh Air Active - boolean
  • Timer Minutes To On - integer
  • Timer Minutes To Off - integer
  • MyZone Number - integer
  • Filter Needs Cleaning - boolean
  • A/C Error Code - string
  • A/C Has Error - boolean
  • MyAuto Running - boolean
  • MyAuto Mode - string
  • Quiet Night Running - boolean
  • Climate Control Running - boolean
  • System Error - string
  • Firmware Update Available - boolean

{ZoneNName} (source) (N = 1-10, same for each)

  • Zone Name - string
  • Zone Open - boolean
  • Zone Closed - boolean
  • Zone Setpoint - integer
  • Damper Percentage - integer
  • Measured Temperature - integer
  • Selected - boolean
  • Zone Fault - boolean
  • Sensor Signal - integer
  • Motion - boolean

{ZoneNName} (per-number) (N = 1-10, same for each)

  • Zone 1 Name - string
  • Zone 1 State - string
  • Zone 1 Open - boolean
  • Zone 1 Closed - boolean
  • Zone 1 Setpoint - integer
  • Zone 1 Damper - integer
  • Zone 1 Temperature - integer
  • Zone 1 Selected - boolean
  • Zone 1 Fault - boolean
  • Zone 1 Sensor Signal - integer
  • Zone 1 Motion - boolean

Selection

  • Selected Zone - integer
  • Selected Zone Name - string

Events

System Events

  • System Power On
  • System Power Off
  • Connection Established
  • Connection Lost

Maintenance / Faults

  • Filter Needs Cleaning
  • Filter Clean (cleared)
  • A/C Fault Detected
  • A/C Fault Cleared

Licence

  • Trial Warning (5 min left)
  • Trial Expired

Schedules

  • Schedule Triggered

{ZoneNName} (N = 1-10, same for each)

  • Zone 1 Opened
  • Zone 1 Closed
  • Zone 1 Motion Detected
  • Zone 1 Fault

Autoprogramming Support

Drop these tags on a button to wire it automatically (command = the press, feedback = the button state).

| Tag | Wires | |---|---| | AC Error Code | feedback | | AC Has Error | feedback | | Climate Control Running | feedback | | Fan High | command + feedback | | Fan Low | command + feedback | | Fan Medium | command + feedback | | Filter Clean Needed | feedback | | Firmware Update Available | feedback | | Fresh Air | feedback | | Last Schedule | feedback | | MyAuto Mode | feedback | | MyAuto Running | feedback | | Next Schedule | feedback | | Power | command | | Power Off | command + feedback | | Power On | command + feedback | | Print Tag Reference | command | | Quiet Night | feedback | | Schedule Count | feedback | | Schedule Disable | command | | Schedule Enable | command | | Schedule Run | command | | Schedules Enabled | feedback | | Schedules Off | command | | Schedules On | command | | Selected Zone | feedback | | Selected Zone Name | feedback | | Stat Cool | command + feedback | | Stat Dry | command + feedback | | Stat Fan Auto | command + feedback | | Stat Fan State | feedback | | Stat Heat | command + feedback | | Stat Mode | feedback | | Stat MyZone | feedback | | Stat MyZone Set | command | | Stat Off | command | | Stat Set Setpoint | command | | Stat Setpoint | feedback | | Stat Setpoint Down | command | | Stat Setpoint Up | command | | Stat Temp In | feedback | | Stat Vent | command + feedback | | System Error | feedback | | Timer Off | feedback | | Timer Off Set | command | | Timer On | feedback | | Timer On Set | command | | Zone N Close (N = 1-10) | command + feedback | | Zone N Damper (N = 1-10) | feedback | | Zone N Fault (N = 1-10) | feedback | | Zone N Motion (N = 1-10) | feedback | | Zone N Name (N = 1-10) | feedback | | Zone N Open (N = 1-10) | command + feedback | | Zone N Select (N = 1-10) | command + feedback | | Zone N Selected (N = 1-10) | feedback | | Zone N Set Damper (N = 1-10) | command | | Zone N Set Temp (N = 1-10) | command | | Zone N Setpoint (N = 1-10) | feedback | | Zone N Signal (N = 1-10) | feedback | | Zone N State (N = 1-10) | feedback | | Zone N Temp Down (N = 1-10) | command | | Zone N Temp In (N = 1-10) | feedback | | Zone N Temp Up (N = 1-10) | command | | Zone N Toggle (N = 1-10) | command | | Zone Damper | command + feedback | | Zone Fault | feedback | | Zone Motion | feedback | | Zone Select | command + feedback | | Zone Selected | feedback | | Zone Signal | feedback | MyAir RTI Driver: STILL NEEDED by hand -> Introduction & Manufacturer Profile, Version History, Driver Features, Supported Devices, Limitations

Limitations

  • No humidity. The MyAir local API does not report humidity.
  • Changes made elsewhere show on the next poll (up to the Poll Interval, default 5 seconds). The tablet does not push changes.
  • The MyAir countdown timer is in minutes from now. For on/off at a real time of day, use the driver's own Schedules.
  • Schedules use the processor clock. If schedules fire at the wrong hour the processor clock is not on local time; set Schedule Time Offset (min) (the debug console command sched now shows the time the driver is using).
  • Import/Export Configuration is not offered in Driver Utilities, because the driver carries the Discover MyAir Zones design-time utility.
  • Web page caching on iPads: after updating the driver, force-quit and reopen the RTI app on each iPad that shows the web page, or it may keep showing the old page.
  • Two instances on one processor must use different Web Server Ports and Debug Ports.
  • Zones beyond 10 per A/C unit are not supported.

Support Contact

Turn on remote logging (the Remote Logging On function) and email us with the processor MAC. We can then see what the driver is doing.

  • Smart Home Programming and Automation - David Bowdler
  • Email - david@smarthomeprogramming.com.au
  • Store and licences - https://shpdrivers.services/store/
  • Web - https://smarthomeprogramming.com.au

Copyright 2026 Smart Home Programming and Automation. All rights reserved.

Licensed per RTI processor. The key is generated from the processor MAC address, and one key covers every A/C unit driven from that processor.

A 120-minute trial runs from each restart without a key. When the trial expires, control commands and schedules stop until a valid key is entered - feedback and status keep running.

Please log in to leave a comment.
Loading comments...