Driver Type
Categories
- Recent Updates
- Access Control
- Amplifier
- A/V Receiver
- Climate and Pool Control
- Disc Player / Changer
- Display
- DSP
- DVR
- Irrigation / Sprinklers
- Lighting Control
- Matrix Switch
- Media Server and Player
- Multi-Room A/V
- Networking
- Power and Rack Management
- Security
- Surveillance
- Teleconferencing
- Training
- Tuner
- Utility
- Video Projector
Driver Type
Categories
- Recent Updates
- Access Control
- Amplifier
- A/V Receiver
- Climate and Pool Control
- Disc Player / Changer
- Display
- DSP
- DVR
- Irrigation / Sprinklers
- Lighting Control
- Matrix Switch
- Media Server and Player
- Multi-Room A/V
- Networking
- Power and Rack Management
- Security
- Surveillance
- Teleconferencing
- Training
- Tuner
- Utility
- Video Projector
HomeSeer
By: David Bowdler
Updated: Nov. 2, 2026
HomeSeer
The first HomeSeer driver for RTI. Two-way control of a HomeSeer HS3, HS4 or HS4 Pro system, including HomeTroller and eHomeSeer hardware, straight over HomeSeer's local JSON API - nothing to install on the HomeSeer side and no cloud account.
Key Features
- Devices: dimmers with 0-100 level sliders, switches, locks, fans and thermostat setpoints, each with its own command and feedback tags
- Sensors: motion, contact, water, temperature, humidity and power, with Active / Inactive and value feedback
- Events: run any HomeSeer event from a button, by picker or by name
- Discovery: Discover HomeSeer Devices and Discover HomeSeer Events fill in every slot from Integration Designer, and re-running them keeps wired buttons pointing at the same device
- Rooms: add each HomeSeer device to a room as its own source
- Feedback: instant push updates on HS4, with polling as a safety net (and on HS3)
- Status: every device reports HomeSeer's own status wording, its value, when it last changed and the state it left
- Safety checks: warns when HomeSeer reuses a device reference, and when new devices or events appear in HomeSeer
Requirements
- HomeSeer HS4 / HS4 Pro (tested on HS4 4.2.23.0) or HS3, reachable from the processor on its web server port (80 by default)
- RTI XP-3 / XP-6 / XP-6s / XP-8 / XP-8s / XP-8v, Integration Designer 11.4 or later, processor runtime 24 or later
How It Works
The driver talks to HomeSeer's own local API. On HS4 HomeSeer pushes each change to the processor the moment it happens; the driver also polls for changes every few seconds, so feedback keeps working on HS3 or if push stops. Nothing is sent to the internet.
HomeSeer | Version 0.37
Introduction
Controls a HomeSeer HS3, HS4 or HS4 Pro system - including HomeTroller and eHomeSeer hardware - from RTI over the local network. Dimmers, switches, locks, fans, thermostats, sensors and HomeSeer events, all with two-way feedback.
Nothing is installed on the HomeSeer side and no cloud account is involved. The driver talks directly to HomeSeer's local JSON API.
HomeSeer Technologies makes the HomeSeer home automation software and the HomeTroller controllers it runs on. This driver is written and supported by Smart Home Programming and Automation.
Important Note
Test HomeSeer Connection and the two Discover commands run inside Integration Designer, on your PC. Nothing you configure is live until you download the project to the processor. If discovery worked but the system seems dead, the download is almost always what is missing.
Use HomeSeer Root Device Names renames every device, and tags are built from device names. Decide on it before you start wiring buttons.
Version History
- 0.37 - Fixes false Device Ref Mismatch errors at start-up. Since 0.28 Discover names devices floor then room, but the start-up check still expected room then floor, so most devices with a floor were reported as mismatched even though they were correct. Real mismatches (a reference now pointing at a device in a different room or on a different floor) are still reported. Trial Time Remaining now reads in hours and minutes (1h 59m).
- 0.36 - Discover HomeSeer Events and Discover HomeSeer Devices no longer clear your slots when HomeSeer sends back a broken list (seen when one HomeSeer event crashes HomeSeer's own event list). They leave every slot as it was and say HomeSeer had a problem. The licence trial is now timed by a one-minute counter instead of the processor clock, which can jump by the time zone shortly after boot. Adds the standard Connection State, Disconnected and License Status variables beside the existing ones, which are unchanged. Remote Logging is now off by default, and the Remote Logging and Debug settings show under Show Advanced. Help is now provided as instructions.md.
- 0.35 - Tags for devices added to rooms are saved into the project. Adding a device to a room is faster.
- 0.33 - Room devices are rebuilt in one pass, and every rebuild is reported.
- 0.32 - Each HomeSeer device can be added to a room as its own source, so the room's pages control that device.
- 0.31 - The general Set Level, Turn On, Turn Off and Toggle commands list your HomeSeer device names. Devices HomeSeer leaves out of its bulk reply are read individually.
- 0.30 - Correct On and Off detection for devices whose On and Off values sit outside the dim range.
- 0.29 - Device and tag lists are sorted by name.
- 0.28 - Device names read floor then room (Main Kitchen - Downlights), HomeSeer's own order.
- 0.27 - Re-running Discover HomeSeer Events keeps each event in the slot it already had, so wired Run Event buttons keep running the same event. Event names in the picker include their group.
- 0.24 - Re-running Discover HomeSeer Devices keeps each device in the slot it already had. Optional HomeSeer root device names. The driver reports devices and events added in HomeSeer since it started.
- 0.22 - Previous state variables (the state a device left, and when).
- 0.20 - Last Changed variable for every device, taken from HomeSeer's own record.
- 0.10 - First release.
Driver Features
- Dimmers, switches, locks, fans, thermostats, sensors and binary sensors, each with its own command and feedback tags.
- Up to 48 dimmers, 64 switches, 12 locks, 12 fans, 8 thermostats, 64 sensors, 96 binary sensors and 120 HomeSeer events.
- Design-time discovery: Discover HomeSeer Devices and Discover HomeSeer Events read HomeSeer and fill in the slots. Re-running them keeps existing devices and events in the slots they already had.
- Each device can be added to a room as its own source.
- Feedback: on HS4 the driver can receive instant push updates (webhook). It also polls HomeSeer for changes every 3 seconds by default (Poll Interval), so feedback works on HS3 and keeps working if push stops.
- Every device reports Status (HomeSeer's own wording), Raw Value, Last Changed and Previous state.
- Run any HomeSeer event by slot, or by group and name as plain text.
- Control Ref By Value and Control Ref By Label for devices that do not fit a slot type, such as alarm panels.
- Checks that each slot's device reference still points at the device it was mapped to, and warns if HomeSeer reused a reference.
- Notices devices and events added in HomeSeer (every 15 minutes by default) and tells you to run Discover.
- Telnet debug console and optional remote logging for support.
Cloud services: none are needed to run the driver. If you switch on Remote Logging (off by default), the driver sends its log lines over HTTPS to shpdrivers.services, run by Smart Home Programming and Automation, so we can help with support. If that server cannot be reached, logging simply stops; control and feedback are not affected.
Supported Devices
- HomeSeer HS4 and HS4 Pro. Tested on a live HS4 4.2.23.0 system with 201 devices and 114 events.
- HomeSeer HS3. Supported through polling (HS3 has no webhook). Not yet tested on a real HS3 system.
- HomeTroller and eHomeSeer controllers, which run HS3 or HS4.
System Requirements & Prerequisites
- Integration Designer - 11.4 or above
- RTI processor - XP-8 class (XP-3 / XP-6 / XP-6s / XP-8 / XP-8s / XP-8v)
- Processor script runtime - 24 or above
Device Setup
Step 1 - Connection
Open Driver Properties and set the HomeSeer IP Address. Port is 80 unless you changed it under Setup - Network - Server Port in HomeSeer.
Leave Username and Password blank if the RTI processor is on the same subnet as HomeSeer - HomeSeer allows local logins without a password by default. If the processor is on a different subnet or VLAN, fill both in; otherwise every request is refused and the driver reports that it cannot log in.
In Driver Properties, open Driver Utilities and run Test HomeSeer Connection. It reports the version, the device count, and whether your system supports instant feedback.
Step 2 - Discover your devices
Run Discover HomeSeer Devices from Driver Utilities. The driver reads every device out of HomeSeer, works out what each one is, and fills in the slots. Then run Discover HomeSeer Events for your scenes. On a large system this can take a minute or two.
Discovery writes ordinary configuration values, so your mapped devices survive a driver update.
If HomeSeer itself fails while listing its devices or events, Discover changes nothing and shows a message. Check the HomeSeer log, fix the cause, and run Discover again.
Step 3 - Download to the processor
Test Connection and Discover talk to HomeSeer directly from your PC. After any change to Driver Properties, download the project to the processor. Until you do, the driver reports Waiting for configuration and buttons do nothing.
To add a device by hand, put its HomeSeer reference number (ref) into the first empty slot of the matching type. The ref is on the device's Advanced tab in HomeSeer.
HS4 root devices
HS4 stores every device twice - a root that carries no controls, plus the feature that actually works. Only the feature can be controlled. Discovery handles this and lists the refs it skipped. A root ref mapped by hand never responds, and the driver says so in the log and the Last Error variable.
Instant feedback on HS4 (recommended)
After loading the driver, read the WebhookURL variable (for example http://192.168.1.20:9070/) and paste it into HomeSeer under Setup - Custom. Feedback then arrives the instant a device changes; watch WebhookCount climb to confirm it. This is optional - the driver always polls as well. The Webhook Port must not be used by any other driver on the same processor.
Which slot type to use
- Dimmer - anything with a level
- Switch - on/off only
- Lock - door locks
- Fan - fan controllers
- Thermostat - heating and cooling setpoints
- Sensor - read-only numbers such as temperature, humidity, power
- Binary - read-only on/off such as motion, contact, water
Device names
HomeSeer names a device by its feature - the word the plugin chose - which often repeats (Control, Switch, Node Status). The driver adds the HomeSeer location to tell them apart, floor then room. Tick Use HomeSeer Root Device Names and re-run Discover to fold in the name you gave the device in HomeSeer. This renames every device, so every button already wired needs re-wiring - decide before you start wiring.
When you add something new in HomeSeer
The driver notices new devices and events within 15 minutes, names them in the log, sets New Devices / New Events Since Startup and fires an event. It cannot map them to a slot by itself; run Discover and download when it suits. Run Event By Name works with any event straight away, with no slot or Discover needed.
Adding a device to a room
Add Workspace Item, choose the room, Drivers tab, HomeSeer, then the device. Leave "Use the source name for the associated driver" ticked. Set a page layer's Source to that device, or drag its tag from the Tag Browser onto a button or slider. After a driver update, run Use HomeSeer Device Names for Tags once.
Wiring buttons
Dropping a tag on a button does not fill its Macro and Variable by itself: Integration Designer autoprograms when a source is added to a room, not when a tag is dropped. Either set Command and Reversed for the tag in the Tag Editor (once per tag - it applies to every button carrying it), or tag your buttons first and add the source afterwards.
For a slider, pick the per-device Level command for Command and the matching Level variable for Value, for the same device.
Button text comes from a token in the button label, not from the tag. Use Edit Button Text with a var token for on/off wording, or a tag token pointed at a text tag for a live reading. On a door contact, Active means open.
Devices that do not fit a slot
Some devices, such as alarm panels, present named actions (Arm Away, Disarm). Use Control Ref By Label. To find the exact label, connect to the debug console, type probe getcontrol2&ref=<ref>, wait two seconds, then type probed.
HomeSeer dashboard on a panel
HomeSeer's own web dashboard can be shown in an RTI Web Object pointed at the controller (for example http://192.168.1.50/). Use the driver for buttons, feedback and macros, and the Web Object for the full HomeSeer interface.
Device reference numbers can change
HomeSeer reuses ref numbers and gives a re-added device a new one. The driver compares each slot's stored name with what HomeSeer reports, raises Ref Mismatch Count and fires Device Ref Mismatch if they differ. Run Verify Device Refs after HomeSeer maintenance - it matters most on locks and garage doors.
Debug console
Telnet to the processor on the Debug Console Port (default 12548, shown under Show Advanced). Commands: status, slots, ctl, discover then devices, verify, webhook, probe <request> then probed, events, events fetch.
Driver Configuration
Connection
- HomeSeer IP Address - IP address of the HomeSeer controller, e.g. 192.168.1.50
- Port - default
80- HomeSeer web server port (Setup > Network > Server Port). Default 80. - Username - Leave BLANK if the processor is on the same subnet as HomeSeer - local logins need no password by default. Required on a different VLAN/subnet.
- Password - Only needed if a Username is set.
- Poll Interval (seconds) - default
3- How often to ask HomeSeer what changed. With the HS4 webhook enabled this is only a safety net, so 3-10s is plenty. - Check HomeSeer For New Items (minutes) - default
15- How often to ask HomeSeer whether devices or events have been ADDED since this driver started. The driver cannot map a new item to a slot on its own - that still needs Discover in Integration Designer - but it will tell you the item exists instead of ignoring it. 0 turns the check off. - Use HomeSeer Root Device Names - default
false- HomeSeer names a device by its FEATURE - the word the plugin chose, which on a real system repeats constantly (Control, Switch, Node Status). Tick this and Discover also folds in the name YOU gave the device in HomeSeer, so three virtual devices all called Control become Porch Lamp Control, Pond Pump Control and so on. WARNING: this RENAMES EVERY DEVICE, and a tag is built from the name, so every button already wired to this driver will need re-wiring. Decide before you start wiring, not after. Re-run Discover after changing it. - Last Changed Format - default
12h- How the per-device Last Changed and Previous variables read on screen. The two Auto settings show the time alone for anything that happened today and add the date once it did not, so a sensor that last moved three weeks ago cannot read as though it just happened. Changing this re-renders every device immediately. - Use Device Names for Tags - default
true- Name the per-device tags after your HomeSeer devices (Porch Lamp Toggle) instead of by slot number (Dimmer 1 Toggle). Applied at discovery and re-applied whenever the project opens. Turn OFF only if you have already wired buttons to the numbered tags, because renaming a tag unbinds anything using it.
Webhook (HS4 push feedback)
- Enable Webhook Receiver - default
true- HS4 only. Lets HomeSeer PUSH device changes to this processor instantly instead of waiting for the next poll. After loading the driver, copy the URL from the WebhookURL system variable into HomeSeer Setup > Custom. HS3 has no webhook - leave this on, it simply will not be used. - Webhook Port - default
9070- Port this driver listens on for HomeSeer webhook POSTs. 0 disables. Must be unique across every driver on this processor.
Dimmers / Lights
- Dimmer N - HomeSeer Ref (N = 1-48) - The HomeSeer device reference number (ref). Find it in HomeSeer under the device's Advanced tab. Leave blank if unused.
- Dimmer N - Name (N = 1-48) - Friendly name shown on the touch panel. Optional - HomeSeer's own name is used if this is blank.
Switches
- Switch N - HomeSeer Ref (N = 1-64) - The HomeSeer device reference number (ref). Find it in HomeSeer under the device's Advanced tab. Leave blank if unused.
- Switch N - Name (N = 1-64) - Friendly name shown on the touch panel. Optional - HomeSeer's own name is used if this is blank.
Locks
- Lock N - HomeSeer Ref (N = 1-12) - The HomeSeer device reference number (ref). Find it in HomeSeer under the device's Advanced tab. Leave blank if unused.
- Lock N - Name (N = 1-12) - Friendly name shown on the touch panel. Optional - HomeSeer's own name is used if this is blank.
Fans
- Fan N - HomeSeer Ref (N = 1-12) - The HomeSeer device reference number (ref). Find it in HomeSeer under the device's Advanced tab. Leave blank if unused.
- Fan N - Name (N = 1-12) - Friendly name shown on the touch panel. Optional - HomeSeer's own name is used if this is blank.
Thermostats
- Thermostat N - HomeSeer Ref (N = 1-8) - The HomeSeer device reference number (ref). Find it in HomeSeer under the device's Advanced tab. Leave blank if unused.
- Thermostat N - Name (N = 1-8) - Friendly name shown on the touch panel. Optional - HomeSeer's own name is used if this is blank.
Sensors
- Sensor N - HomeSeer Ref (N = 1-64) - The HomeSeer device reference number (ref). Find it in HomeSeer under the device's Advanced tab. Leave blank if unused.
- Sensor N - Name (N = 1-64) - Friendly name shown on the touch panel. Optional - HomeSeer's own name is used if this is blank.
Binary Sensors
- Binary N - HomeSeer Ref (N = 1-96) - The HomeSeer device reference number (ref). Find it in HomeSeer under the device's Advanced tab. Leave blank if unused.
- Binary N - Name (N = 1-96) - Friendly name shown on the touch panel. Optional - HomeSeer's own name is used if this is blank.
Events (Scenes)
- Event N - Name (N = 1-120) - HomeSeer event name, exactly as shown in HomeSeer.
- Event N - Group (N = 1-120) - HomeSeer event group. Required unless an Event Id is set.
- Event N - Id (optional) (N = 1-120) - Numeric event id. If set, this is used instead of Group + Name.
Licensing
- Licence Key - Per-processor licence key. Without one the driver runs a 120 minute trial each time it loads.
Remote Logging (Support Diagnostics)
- Remote Logging - default
false- Off by default. When on, sends this driver's log lines to shpdrivers.services (HTTPS) so Smart Home Programming can help with support. - Log Server Host - default
shpdrivers.services- Use 209.38.27.58 if DNS is blocked. - Log Server Port - default
443- HTTPS port of the log server. Leave at 443.
Debug
- Debug Level - default
0- 0 off, 1 info, 2 trace. - Debug Console Port - default
12548- Telnet diagnostic console. 0 disables.
Licensing
The driver runs a 120 minute trial each time it loads, so you can build and test a job before licensing it. When the trial ends, control commands stop and the driver logs that a command was blocked; feedback keeps updating. If buttons stop working, check the License Status variable (Licensed / Trial / Unlicensed) first.
A licence key is tied to the RTI processor's MAC address, shown in the MAC For Key variable. Enter it as Licence Key in Driver Properties. Buy a licence at https://smarthomeprogramming.com.au/store/.
Functions
Dimmers / Lights
- Turn On - Dimmer (48 choices)
- Turn Off - Dimmer (48 choices)
- Toggle - Dimmer (48 choices)
- Set Level - Dimmer (48 choices), Level %
Switches
- Turn On - Switch (64 choices)
- Turn Off - Switch (64 choices)
- Toggle - Switch (64 choices)
Locks
- Lock - Lock (12 choices)
- Unlock - Lock (12 choices)
Fans
- Turn On - Fan (12 choices)
- Turn Off - Fan (12 choices)
- Set Speed - Fan (12 choices), Speed %
Thermostats
- Set Setpoint - Thermostat (8 choices), Temperature
Dimmers / Lights - per device (tags)
- {DimmerNName} On (N = 1-48)
- {DimmerNName} Off (N = 1-48)
- {DimmerNName} Toggle (N = 1-48)
- {DimmerNName} Level (N = 1-48) - Level % (N-N)
Switches - per device (tags)
- {SwitchNName} On (N = 1-64)
- {SwitchNName} Off (N = 1-64)
- {SwitchNName} Toggle (N = 1-64)
Locks - per device (tags)
- {LockNName} Lock (N = 1-12)
- {LockNName} Unlock (N = 1-12)
Fans - per device (tags)
- {FanNName} On (N = 1-12)
- {FanNName} Off (N = 1-12)
- {FanNName} Speed (N = 1-12) - Speed % (N-N)
Thermostats - per device (tags)
- {ThermostatNName} Temp (N = 1-8) - Temperature (N-N)
Events (Scenes)
- Run Event - Event (120 choices)
- Run Event By Name - Group, Name
Advanced
- Control Ref By Value - HomeSeer Ref, Value
- Control Ref By Label - HomeSeer Ref, Label
Diagnostics
- Discover Devices
- Verify Device Refs
- Refresh
- Print Tag Reference
- Remote Logging On
- Remote Logging Off
- Remote Logging Toggle
Variables
Driver Status
- Driver Version - string
- Connected - boolean
- Disconnected - boolean
- Controller Status - string
- HomeSeer Version - string
- Configured Device Count - integer
- HomeSeer Event Count - integer
- Last Error - string
- Last Event Run - string
- Webhook URL (give this to HomeSeer) - string
- Webhook Messages Received - integer
- Discovered Device Count - integer
- Ref Mismatch Count - integer
- HomeSeer Device Total - integer
- New Devices Since Startup - integer
- New Events Since Startup - integer
- New Items Status - string
- Connection State - integer (0=Disconnected, 1=Connected)
Licensing
- Licence Valid - boolean
- Licence Status - string
- Trial Active - boolean
- Trial Expired - boolean
- Trial Time Remaining - string
- MAC For Key - string
- License Status - string
- License Status - Licensed - boolean
- License Status - Trial - boolean
- License Status - Unlicensed - boolean
Dimmers / Lights
- Dimmer N Name (N = 1-48) - string
- {DimmerNName} Status (N = 1-48) - string
- {DimmerNName} Raw Value (N = 1-48) - integer
- {DimmerNName} Last Changed (N = 1-48) - string
- {DimmerNName} Previous (N = 1-48) - string
- {DimmerNName} Previous Status (N = 1-48) - string
- {DimmerNName} Previous Time (N = 1-48) - string
- {DimmerNName} On (N = 1-48) - boolean
- {DimmerNName} Off (N = 1-48) - boolean
- {DimmerNName} Toggle (N = 1-48) - boolean
- {DimmerNName} Level (N = 1-48) - integer
- {DimmerNName} Level Text (N = 1-48) - string
Switches
- Switch N Name (N = 1-64) - string
- {SwitchNName} Status (N = 1-64) - string
- {SwitchNName} Raw Value (N = 1-64) - integer
- {SwitchNName} Last Changed (N = 1-64) - string
- {SwitchNName} Previous (N = 1-64) - string
- {SwitchNName} Previous Status (N = 1-64) - string
- {SwitchNName} Previous Time (N = 1-64) - string
- {SwitchNName} On (N = 1-64) - boolean
- {SwitchNName} Off (N = 1-64) - boolean
- {SwitchNName} Toggle (N = 1-64) - boolean
Locks
- Lock N Name (N = 1-12) - string
- {LockNName} Status (N = 1-12) - string
- {LockNName} Raw Value (N = 1-12) - integer
- {LockNName} Last Changed (N = 1-12) - string
- {LockNName} Previous (N = 1-12) - string
- {LockNName} Previous Status (N = 1-12) - string
- {LockNName} Previous Time (N = 1-12) - string
- {LockNName} Lock (N = 1-12) - boolean
- {LockNName} Unlock (N = 1-12) - boolean
Fans
- Fan N Name (N = 1-12) - string
- {FanNName} Status (N = 1-12) - string
- {FanNName} Raw Value (N = 1-12) - integer
- {FanNName} Last Changed (N = 1-12) - string
- {FanNName} Previous (N = 1-12) - string
- {FanNName} Previous Status (N = 1-12) - string
- {FanNName} Previous Time (N = 1-12) - string
- {FanNName} On (N = 1-12) - boolean
- {FanNName} Off (N = 1-12) - boolean
- {FanNName} Speed (N = 1-12) - integer
- {FanNName} Speed Text (N = 1-12) - string
Thermostats
- Thermostat N Name (N = 1-8) - string
- {ThermostatNName} Status (N = 1-8) - string
- {ThermostatNName} Raw Value (N = 1-8) - integer
- {ThermostatNName} Last Changed (N = 1-8) - string
- {ThermostatNName} Previous (N = 1-8) - string
- {ThermostatNName} Previous Status (N = 1-8) - string
- {ThermostatNName} Previous Time (N = 1-8) - string
- {ThermostatNName} Temp (N = 1-8) - string
Sensors
- Sensor N Name (N = 1-64) - string
- {SensorNName} Status (N = 1-64) - string
- {SensorNName} Raw Value (N = 1-64) - integer
- {SensorNName} Last Changed (N = 1-64) - string
- {SensorNName} Previous (N = 1-64) - string
- {SensorNName} Previous Status (N = 1-64) - string
- {SensorNName} Previous Time (N = 1-64) - string
- {SensorNName} Value (N = 1-64) - integer
Binary Sensors
- Binary N Name (N = 1-96) - string
- {BinaryNName} Status (N = 1-96) - string
- {BinaryNName} Raw Value (N = 1-96) - integer
- {BinaryNName} Last Changed (N = 1-96) - string
- {BinaryNName} Previous (N = 1-96) - string
- {BinaryNName} Previous Status (N = 1-96) - string
- {BinaryNName} Previous Time (N = 1-96) - string
- {BinaryNName} Active (N = 1-96) - boolean
- {BinaryNName} Inactive (N = 1-96) - boolean
Events (Scenes)
- {EventNGroup} - {EventNName} (N = 1-120) - string
Events
Connection
- Connected
- Disconnected
Events (Scenes)
- HomeSeer Event Run
Diagnostics
- Device Ref Mismatch
- New Devices Found In HomeSeer
- New Events Found In HomeSeer
Licensing
- Trial Warning
- Trial Expired
- Trial Started
- Licence Activated
Dimmers / Lights Changes
- {DimmerNName} Changed (N = 1-48)
Switches Changes
- {SwitchNName} Changed (N = 1-64)
Locks Changes
- {LockNName} Changed (N = 1-12)
Fans Changes
- {FanNName} Changed (N = 1-12)
Thermostats Changes
- {ThermostatNName} Changed (N = 1-8)
Sensors Changes
- {SensorNName} Changed (N = 1-64)
Binary Sensors Changes
- {BinaryNName} Changed (N = 1-96)
Autoprogramming Support
Drop these tags on a button to wire it automatically (command = the press, feedback = the button state).
| Tag | Wires | |---|---| | Binary N Active (N = 1-96) | feedback | | Binary N Inactive (N = 1-96) | feedback | | Binary N Last Changed (N = 1-96) | feedback | | Binary N Previous (N = 1-96) | feedback | | Binary N Previous Status (N = 1-96) | feedback | | Binary N Previous Time (N = 1-96) | feedback | | Binary N Raw Value (N = 1-96) | feedback | | Binary N Status (N = 1-96) | feedback | | Dimmer N Last Changed (N = 1-48) | feedback | | Dimmer N Level (N = 1-48) | command + feedback | | Dimmer N Level Text (N = 1-48) | feedback | | Dimmer N Off (N = 1-48) | command + feedback | | Dimmer N On (N = 1-48) | command + feedback | | Dimmer N Previous (N = 1-48) | feedback | | Dimmer N Previous Status (N = 1-48) | feedback | | Dimmer N Previous Time (N = 1-48) | feedback | | Dimmer N Raw Value (N = 1-48) | feedback | | Dimmer N Status (N = 1-48) | feedback | | Dimmer N Toggle (N = 1-48) | command + feedback | | Fan N Last Changed (N = 1-12) | feedback | | Fan N Off (N = 1-12) | command + feedback | | Fan N On (N = 1-12) | command + feedback | | Fan N Previous (N = 1-12) | feedback | | Fan N Previous Status (N = 1-12) | feedback | | Fan N Previous Time (N = 1-12) | feedback | | Fan N Raw Value (N = 1-12) | feedback | | Fan N Speed (N = 1-12) | command + feedback | | Fan N Speed Text (N = 1-12) | feedback | | Fan N Status (N = 1-12) | feedback | | Lock N Last Changed (N = 1-12) | feedback | | Lock N Lock (N = 1-12) | command + feedback | | Lock N Previous (N = 1-12) | feedback | | Lock N Previous Status (N = 1-12) | feedback | | Lock N Previous Time (N = 1-12) | feedback | | Lock N Raw Value (N = 1-12) | feedback | | Lock N Status (N = 1-12) | feedback | | Lock N Unlock (N = 1-12) | command + feedback | | Sensor N Last Changed (N = 1-64) | feedback | | Sensor N Previous (N = 1-64) | feedback | | Sensor N Previous Status (N = 1-64) | feedback | | Sensor N Previous Time (N = 1-64) | feedback | | Sensor N Raw Value (N = 1-64) | feedback | | Sensor N Status (N = 1-64) | feedback | | Sensor N Value (N = 1-64) | feedback | | Switch N Last Changed (N = 1-64) | feedback | | Switch N Off (N = 1-64) | command + feedback | | Switch N On (N = 1-64) | command + feedback | | Switch N Previous (N = 1-64) | feedback | | Switch N Previous Status (N = 1-64) | feedback | | Switch N Previous Time (N = 1-64) | feedback | | Switch N Raw Value (N = 1-64) | feedback | | Switch N Status (N = 1-64) | feedback | | Switch N Toggle (N = 1-64) | command + feedback | | Thermostat N Last Changed (N = 1-8) | feedback | | Thermostat N Previous (N = 1-8) | feedback | | Thermostat N Previous Status (N = 1-8) | feedback | | Thermostat N Previous Time (N = 1-8) | feedback | | Thermostat N Raw Value (N = 1-8) | feedback | | Thermostat N Status (N = 1-8) | feedback | | Thermostat N Temp (N = 1-8) | command + feedback |
Limitations
- HS3 has no webhook, so feedback on HS3 arrives at the Poll Interval rather than instantly.
- A device or event added in HomeSeer is not mapped to a slot until you run Discover in Integration Designer and download.
- HomeSeer events report no enabled or disabled state, so the driver cannot show it.
- If HomeSeer fails while listing its events (for example because one event refers to a device that no longer exists), Discover cannot fill event slots until the HomeSeer fault is fixed. Run Event By Name still works.
- Use HomeSeer Root Device Names changes device names, which unbinds buttons wired to the old tag names.
Support Contact
Smart Home Programming and Automation
- Email: david@smarthomeprogramming.com.au
- Phone: 0401 190 122
- Web: https://smarthomeprogramming.com.au
120-minute free trial every time the driver loads. A licence is per RTI processor and is bound to its MAC address - read the MAC from the driver's MAC For Key variable. When the trial ends, control stops but feedback keeps updating. Buy at smarthomeprogramming.com.au/store.