Driver Type
Categories
- Recent Updates
- Access Control
- Amplifier
- A/V Receiver
- Climate and Pool Control
- Disc Player / Changer
- Display
- DSP
- DVR
- Irrigation / Sprinklers
- Lighting Control
- Matrix Switch
- Media Server and Player
- Multi-Room A/V
- Networking
- Power and Rack Management
- Security
- Surveillance
- Teleconferencing
- Training
- Tuner
- Utility
- Video Projector
Driver Type
Categories
- Recent Updates
- Access Control
- Amplifier
- A/V Receiver
- Climate and Pool Control
- Disc Player / Changer
- Display
- DSP
- DVR
- Irrigation / Sprinklers
- Lighting Control
- Matrix Switch
- Media Server and Player
- Multi-Room A/V
- Networking
- Power and Rack Management
- Security
- Surveillance
- Teleconferencing
- Training
- Tuner
- Utility
- Video Projector
Hayward OmniLogic
By: David Bowdler
Updated: Oct. 6, 2026
Hayward OmniLogic
RTI control of Hayward OmniLogic, OmniPL and OmniHub pool and spa controllers over the controller's local network interface. There is no Hayward account, no cloud service and no internet dependency required — the driver talks to the controller directly on the local network and keeps working with no internet connection at all.
Key Features
- Equipment discovered, not typed: run Discover Equipment once and the driver reads the pool's real equipment list — every pump, heater, chlorinator, ColorLogic light, relay and group arrives with the name it has in the Hayward app, each with its own tags, live feedback and events.
- Names you control: rename any item in Driver Properties to suit the job; renaming it later in the Hayward app does not disturb your wiring.
- One tag wires command and feedback together: for example Water Feature On / Off / Toggle sends the command and lights the button from the live state, with no extra wiring.
- Pumps: on/off and variable speed, with a Filter Pump Speed slider tag that both sets and shows the current speed.
- Heaters (gas, solar and heat pump): setpoint, setpoint up/down, and live target temperature.
- ColorLogic lights: on/off and light-show selection by name, with the current show reported back as a name, plus brightness and show speed on UCL / 4.0 lights.
- One button per light show: each show gets its own tag that selects it and highlights only while that show is running.
- Chlorinator: output percent, boost (super-chlorinate) on/off, salt level, and alert/error flags that only show while there is actually a problem.
- Relays, valves and groups: on/off with live feedback.
- On For timers: On For Minutes and Cancel Timer on any pump, light or relay, with the countdown handed to the controller so it still switches off if the processor restarts.
- Auto-Off safety: a per-device maximum run time that turns an item off however it was switched on, so a forgotten drain cannot empty the pool.
- Sample project included: a real installer's pool page plus test pages for every command and feedback the driver builds.
- Read-only sensors: pool water temperature, flow, air temperature, pump power and salt level.
- Pool dashboard Web Object: a full dashboard is served from the processor itself at http://<processor-ip>:9075/ — fully live and controllable, with no internet connection needed.
- Print Tag Reference: lists every tag for your discovered pool straight into TraceView.
Requirements
- A Hayward OmniLogic, OmniPL or OmniHub pool controller with a static IP address on the local network — this is the only requirement on the Hayward side.
- RTI XP processor (runtime 24+), Integration Designer 11.4 or later.
- The RTI processor and the controller on the same network, with UDP not blocked between them.
- The PC running Integration Designer must also be able to reach the controller, for the one-off Discover Equipment step.
How It Works
Add the driver, enter the controller's IP, then run Discover Equipment once from Driver Utilities — the driver talks to the controller over its local control port, reads the equipment list and builds its own variables, functions and tags around the actual pool. From then on, control flows directly between the processor and the controller on the local network: no cloud, no Hayward account, and nothing for a manufacturer web service to switch off. If equipment is ever added to the pool, running Discover Equipment again picks it up without disturbing existing button wiring.
Hayward OmniLogic
Version 0.20
Controls a Hayward OmniLogic, OmniPL or OmniHub pool controller over the LOCAL network.No Hayward account, no cloud service and no internet connection are required.
Before you start
- Give the pool controller a STATIC IP on the local network. This is the only requirement.
- The processor and the controller must be on the same network.
Setting up
1. Add the driver and enter the controller's IP in Controller IP.
2. Right-click the driver and choose Driver Utilities, then 1 - Discover Equipment.
3. The driver reads your equipment list from the controller and builds itself around it,using the real names you gave each item in the Hayward app.
4. Paste your licence key into Licence Key. Without one the driver runs for two hoursat a time so you can test it.
Naming your equipment
After Discover Equipment, every item is listed under Equipment in Driver Properties,starting with the name it has in the Hayward app. Change any name you like - forexample Water Feat to Water Feature, or Heater 3 to Pool Heater. The name you set hereis what appears in the Tag Browser, in the variable list and on the pool dashboard.
Renaming an item in the Hayward app later does NOT change anything here, so yourwiring is safe. Only editing the name in Driver Properties renames its tags - if youdo that after wiring buttons, drop the new tags on those buttons again.
Tags
Each item's tags start with its name. One tag wires a button's command AND itsfeedback together, so the button shows the live value with no extra work:
- Water Feature On / Off - the button lights while it is on or off.
- Water Feature Toggle - one button that switches it and lights while it is on.
- Filter Pump Speed - a slider that sets the speed and shows the current speed.
- Pool Heater Setpoint - sets the temperature and shows the current target.
- Pool Heater Setpoint Up / Setpoint Down - step the target one degree.
- Color Lights Show - selects a light show and shows the current one.
- Color Lights Show Name - the current show as text (e.g. Voodoo Lounge) for button labels; the Show variable stays as the number for programming. In a macro, Set Light Show offers the show names for that light as a list.
- Color Lights Show Voodoo Lounge (one tag for every show of that light) - drop it on a show button and it selects that show AND lights only while the light is on that show. Use these for a list of show buttons; Color Lights Is On would light every one of them.
- Every item that can be switched also has Turned On and Turned Off events, fired when the controller reports the change - whether it came from RTI, the Hayward app or the controller's own schedule. They do not fire when the driver first starts.
- Chlorinator Percent - output percent. Chlorinator Boost On / Off - super chlorinate.
Read-only values have their own tags: Pool Water Temperature, Pool Flow, AirTemperature, Filter Pump Power, Chlorinator Salt Level, Chlorinator Salt Level Instant,and Chlorinator Alert / Error, which show only while the chlorinator reports a problem.Sensors and internal parts such as the gas heater unit have no tags.
To list every tag for your pool, run the Print Tag Reference command and read it inTraceView.
Timed runs (On For Minutes)
Relays, lights and pumps have an On For Minutes command (tag: <name> On For) that turns the item on and turns it off again after the number of minutes you give it. Use it for anything that must never be left running - a drain valve, a water feature or a pump boost.
The off is enforced twice. The OmniLogic is asked to count down itself, and the driver also keeps its own deadline, saved so a processor reboot does not lose it. At the deadline the driver sends Off and keeps sending it every 15 seconds until the controller reports the item off. Switching the item off any other way - the Off button, the Hayward app - ends the timer. Cancel Timer ends it and leaves the item running.
The safety off is sent even if the trial has expired.
Variables per item: Timer Running and Timer Not Running (for show/hide), Timer Minutes Left, and Timer Countdown (text such as 12:34 for a button label).
Events per item: Timer Finished, and Timer Could Not Turn Off, which fires if the item is still on 3 minutes after its timer ran out (the driver keeps trying).
If an On For command does not turn the item on at all, turn off Controller Countdown under Timers in Driver Properties; the driver then runs the timer on its own.
Auto-Off
Under Timers in Driver Properties every relay, light and pump also has an Auto-Off (minutes) setting, 0 by default (never). Set it on anything that must never run unattended - a drain, for example. However the item comes on - the On button, Toggle, a scene, the Hayward app or the controller's own schedule - the driver turns it off again after that many minutes, using the same enforced timer as On For. An On For command overrides it for that run. Cancel Timer leaves the item running until it next goes off; the limit applies again to the next run.
Pool dashboard (Web Object)
The driver serves a full pool dashboard from the processor itself. Add a Web Objectto a page and point it at http://<processor-ip>:9075/ - nothing is hosted online andit keeps working with no internet connection.
It shows the pool as a grid of tiles: water temperature, heater setpoint, pump speed,chlorinator output and salt level, each light with its current show, every relay, andyour scenes. Everything on it is live.
Tap a relay tile (a drain valve, a water feature) to switch it, or a scene tile to runit. Tap the heater, pump, chlorinator or a light for its full controls: the setpointbuttons, a speed slider with quick 25/50/75/100 percent buttons, or the light panelwith every light show for that model of light and, on ColorLogic UCL and 4.0 lights,the brightness and show speed. Picking a show turns the light on.
Nothing on the dashboard ever scrolls. It is drawn at a readable size and the tilesare arranged to fit whatever size and shape you draw the Web Object - a wide panel, aniPad, a phone held upright, or a small tile on a page. If a small Web Object cannot fitevery tile, the dashboard shows them a page at a time with arrows to move betweenpages. Rotate the device and it re-fits.
Tap the cog at the top right for the dashboard settings: a ready-made theme or yourown background and accent colours, the Size (Small to Largest, to make everythingbigger or smaller), and the title. Tap the tick to save. The settings are saved on theprocessor, so every panel shows the same look. The Size tab also shows the WebObject's actual size, which helps when choosing how big to draw it.
Change the port under Web Object if 9075 is already used on the processor, or set itto 0 to switch the dashboard off. Remember to change the Web Object URL to match.
If the page looks stale on an iPad, force-quit the RTI app and reopen it. The panelapp caches web content per button slot, so a reload alone will not clear it.
If new equipment is added to the pool
Run Discover Equipment again. Existing wiring is preserved.
Troubleshooting
- No connection: check the controller has a static IP and is reachable from the processor.
- Discover Equipment reports no reply: the PC running Integration Designer must also beable to reach the controller, and UDP must not be blocked.
- For diagnostics, telnet the processor on port 12552 and type status or devices.
- If Smart Home Programming asks for a log, tick Remote Logging under Diagnostics inDriver Properties, or wire a button to the Remote Logging On command. It sends thedriver log to us so we can see what the controller is doing. Turn it off afterwards.
Support
Smart Home Programming - https://smarthomeprogramming.com.au
This driver requires a licence key tied to your RTI processor's MAC address.
- Trial: runs for 2 hours at a time, fully functional, no key required — reload the driver for another 2-hour window
- Purchase: Visit https://smarthomeprogramming.com.au/store/ to buy a licence
- Licence is per-processor — one key per XP processor