Driver Type
Categories
- Recent Updates
- Access Control
- Amplifier
- A/V Receiver
- Climate and Pool Control
- Disc Player / Changer
- Display
- DSP
- DVR
- Irrigation / Sprinklers
- Lighting Control
- Matrix Switch
- Media Server and Player
- Multi-Room A/V
- Networking
- Power and Rack Management
- Security
- Surveillance
- Teleconferencing
- Training
- Tuner
- Utility
- Video Projector
Driver Type
Categories
- Recent Updates
- Access Control
- Amplifier
- A/V Receiver
- Climate and Pool Control
- Disc Player / Changer
- Display
- DSP
- DVR
- Irrigation / Sprinklers
- Lighting Control
- Matrix Switch
- Media Server and Player
- Multi-Room A/V
- Networking
- Power and Rack Management
- Security
- Surveillance
- Teleconferencing
- Training
- Tuner
- Utility
- Video Projector
Blustream MV41 (ICP)
By: David Bowdler
Updated: Nov. 20, 2026
Blustream MV41 Multiview Switcher (ICP)
Full two-way RTI control of the Blustream MV41 4x1 HDMI multiview switcher from an RTI ICP processor, over TCP/IP (Telnet port 23 or TCP 8000) or RS-232, using the MV41's documented control protocol. It has the same functions, variables and tags as the XP build, so a panel built for one works with the other. For an RTI XP processor, use the XP build.
Key Features
- Full screen in one press: any of the four inputs, with the button lit while that input fills the screen.
- All 16 multiview layouts: side by side, top and bottom, the four PIP corners, the four triple layouts, quad square and the four quad large layouts, each with its own lit button, plus Layout Next / Previous and a configurable Multiview button.
- Window routing: put any input in any window, swap two windows, or promote an input to the big window. When the input you promote was already in a small window, the one it replaces moves into that window, so nothing disappears from the screen.
- Audio: from an input, follow a window, or mute, with a Mute Toggle that remembers where to go back to.
- Presets that follow the screen: recall any of the eight MV41 presets, and Preset N Active lights whenever the screen shows exactly what that preset holds, however it got there.
- Real two-way feedback: changes made from the MV41's own web page, front panel, IR remote or another control system show up on the panel.
- No silent failures: when the MV41 refuses a command (for example while it is in standby) its own reason lands in a Last Error variable and an event fires. Change events fire only once the MV41 confirms the change, so a refused command never runs a macro.
- One-page demo included: the download includes a finished one-page iPad control page to copy from.
- Built for support: optional remote logging so a fault can be diagnosed without attending site.
Requirements
- A Blustream MV41 4x1 HDMI multiview switcher, firmware MCU 1.4.0 or later
- An RTI ICP processor (ICP-2, ICP-4 or ICP-10) with Integration Designer 12
- For IP: a fixed address for the MV41 (DHCP reservation or a static address from its web page), with Telnet left enabled
- For RS-232: 57600 8N1, three wires - TX to RX, RX to TX, and ground. A missing ground is the most common cause of a dead serial link
How It Works
The driver keeps one connection to the MV41 open and sends one command at a time, reading the MV41's own answer to each. It reads the MV41's full status on connect and then every few seconds, and straight after every change, so the panel always shows what the screen is really doing. The MV41 does not announce changes made from its web page, front panel or IR remote, so those show up at the next status read. Tested on an ICP-2 (firmware 26.11.3) against a real MV41 (MCU V1.4.0 / GUI V1.5.0), over both network and RS-232. The download includes a finished one-page iPad control page (SampleFile.id), instructions and an Integration Note.
Support: smarthomeprogramming.com.au
Blustream MV41 (ICP) | Version 0.3.1
Introduction
Controls the Blustream MV41 4x1 HDMI multiview switcher from an RTI ICP processor, over the network or RS-232. Full screen any input, pick any of the 16 multiview layouts, put any input in any window, promote an input to the main window, choose the audio source, recall presets, and set the output resolution and EDID. Everything comes back as two-way feedback, including changes made from the MV41's web page, its front panel, its IR remote or another control system.
Blustream makes the MV41. This driver is written and supported by Smart Home Programming and Automation.
Important Note
The MV41 needs its main output to be the TV's only input. Set the TV to the MV41's HDMI input and leave it there; every source change happens in the MV41.
Changing the layout always sends the inputs for every window. The MV41 firmware refuses a layout change on its own, so the driver sends the inputs each window is showing now, and the layout changes without the windows jumping around. Turn off "Keep Window Inputs On Layout Change" if you would rather every layout start with inputs 1, 2, 3, 4.
Version History
- 0.3.1 - The default control port is now 8000 (raw TCP) instead of 23 (Telnet). On site an MV41 would not hold a Telnet connection on 23 but connected straight away on 8000. Existing installs keep whatever port is already set in Driver Properties.
- 0.3.0 - Reliability fixes from a full test run against a real MV41 and the simulator. Change events (Layout, Main Window, Audio, Power) now fire only when the MV41 confirms the change, so a command it refuses (for example in standby) no longer runs a macro twice. The serial port is retried if it cannot be opened or closes. Preset and output names with spaces (renamed in the web page) are read correctly. Send Raw handles STATUS and PON properly. Empty function parameters are ignored instead of being read as 0.
- 0.2.0 - Remote logging added: Remote Logging On/Off/Toggle functions, a Remote Logging Active variable and a Remote Logging (Development) settings category. Off by default; turn it on only when SHP support asks.
- 0.1.0 - First ICP release. Built from the XP driver v0.3: the same functions, variables, events and tags, so a panel made for the XP driver works with this one. Tested against an MV41 simulator; not yet tested on an ICP processor.
Driver Features
- Full screen. One button per input. The button lights while that input is full screen.
- All 16 multiview layouts. Side by side, top and bottom, four picture-in-picture corners, four triple layouts and five quad layouts, including the 1 large + 3 small layouts. Next / Previous layout buttons too.
- Window routing. Put any input in any window, with a button per window per input that lights to show what each window is showing.
- Main window. Promote any input to the big window. If that input was already showing in a small window, the input it replaces moves into that small window, so nothing disappears from the screen.
- Audio. Audio from an input, from a window (audio follows that window), or muted. Mute Toggle remembers the source to go back to.
- Presets. Apply and save the MV41's 8 presets. The driver shows which presets have something saved and which was applied last.
- Video. Output resolution, seamless switching, auto switching and per-input EDID.
- Live feedback. Changes made in another Telnet session show up within a second. Web page, front panel and IR changes show up at the next status read (every 10 seconds by default).
- Rejected commands are visible. When the MV41 refuses a command, its reason goes into the Last Error variable and the Command Rejected event fires.
- Reconnects by itself after a network drop or if the MV41 stops answering.
- Input names. Name each input once in Driver Properties and the names are used on buttons, in variables and in the function pickers.
- Same panel as the XP driver. Every function export, variable and tag matches the XP driver, so an existing panel moves to an ICP without re-tagging.
- Logging. Turn on Enable Trace (Debug settings) to see every command and reply in TraceViewer. Remote logging can send the same log to SHP support when we ask for it.
Supported Devices
- Blustream MV41 4-way multiview HDMI switcher.
Tested on firmware MCU V1.4.0 / GUI V1.5.0. Firmware 1.4.0 added the window routing command this driver relies on; update older units from the Blustream website before installing.
System Requirements
- RTI ICP processor (ICP-2, ICP-4, ICP-10).
- Integration Designer 12.0 or later.
- The MV41 on the same network as the processor, or an RS-232 cable.
For an XP-series processor, use the Blustream MV41 XP driver instead.
Device Setup
Network. The MV41 uses DHCP out of the box. Give it a DHCP reservation or a static address from its web page, so the address does not change. Use port 8000 (the default) or port 23 (Telnet); both carry the same commands. If you use 23, Telnet must stay enabled on the MV41.
EDID. Set Input EDID only works when the four EDID DIP switches on the side of the MV41 are all set to 1 (1111, software EDID). In any other position the MV41 refuses the command and says so in the Last Error variable.
RS-232. The MV41 has a 3-pin Phoenix connector. The settings are 57600 baud, 8 data bits, no parity, 1 stop bit. Cross TX and RX between the processor and the MV41, and always connect ground.
Use the RS-232 adapter that came with the processor and check its pinout in the processor manual: processor transmit goes to the MV41 RX, processor receive to the MV41 TX, and ground to ground.
Driver Configuration
Connection Settings
- Connection Type - Network (IP) or Serial (RS-232).
- IP Address - the MV41's address (network only).
- Port - 8000 for raw TCP (default) or 23 for Telnet (network only).
- Serial Port - the processor port the MV41 is wired to (serial only).
- Device Label - optional. Shown at the start of each log line when more than one MV41 is in the project.
Input Names - a name for each HDMI input, used everywhere the driver shows an input.
Options
- Status Poll (seconds) - how often the driver reads the full status. Default 10. Changes made through the driver show at once whatever this is set to.
- Keep Window Inputs On Layout Change - on (default) keeps each window's input when the layout changes. Off starts every layout with inputs 1, 2, 3, 4.
- Default Layout For Multiview - the layout the Multiview function uses. Default 13 (Quad Large Left).
Licence - paste your licence key here.
Remote Logging (Development) - Remote Logging (off by default), Log Server Host and Log Server Port. Turn it on only when SHP support asks. You can also switch it with the Remote Logging On / Off / Toggle functions, and the choice is remembered after a reload. If the site cannot look up shpdrivers.services, set Log Server Host to 209.38.27.58.
Debug (hidden) - Enable Trace logs every command and reply to TraceViewer.
Cloud services. The driver uses one cloud service, and only while Remote Logging is on: it sends the driver's log lines (commands, replies and status, tagged with the processor's MAC address) to shpdrivers.services, run by Smart Home Programming and Automation. With Remote Logging off, nothing leaves the site. Control of the MV41 never depends on the internet.
Licensing
The driver runs fully for a 120 minute trial each time it loads. After that it keeps reading the MV41's status but stops sending commands until a licence key is entered. A key is tied to one processor; buy it at https://smarthomeprogramming.com.au/store and give the processor's MAC address, shown in the MAC For Key variable. XP keys do not work on this driver.
Functions
- Power - Power On, Power Off, Power Toggle, Output On, Output Off.
- Full Screen - one function per input, and Full Screen (choose input).
- Layouts - one function per layout, Set Layout (choose), Multiview (default layout), Next Layout, Previous Layout.
- Window N Input - one function per window per input.
- Window Routing - Set Window Input (choose), Swap Two Windows, All Windows From One Input, Set Window Inputs 1-4 (any window can be left as it is).
- Main Window - one function per input, Main Window (choose input), Multiview With Main Input (a layout with the chosen input in the main window and the others filling the rest).
- Audio - Audio Muted, Audio Input 1-4, Audio Window 1-4, Audio Mute Toggle, Audio Source (choose).
- Presets - Apply Preset 1-8, Apply Preset (choose), Save Current To Preset.
- Video and EDID - Output Resolution, Seamless Switching On / Off, Auto Switching On / Off, Set Input EDID.
- Diagnostics - Refresh Status, Reconnect, Send Raw Command, Print Tag Reference. Send Raw Command refuses network and reset commands so a mistyped macro cannot take the MV41 off the network.
Variables
- Connection - Connection State (0 Disconnected, 1 Connecting, 2 Connected), Connected, Disconnected, Connecting, Connection Status, Last Result, Last Error.
- Device - Driver Version, Firmware Version, Temperature, Uptime, MV41 IP Address, MV41 MAC Address.
- Power and Output - Power State (0 Off, 1 On), Power Is On, Power Is Off, Output Enabled, Output Disabled, Display Connected, Display Not Connected, Output Resolution.
- Layout - Layout (number, with names), Layout Name, Window Count, Single View, Multiview, and one Layout Is ... boolean per layout.
- Window 1-4 - Window Input (number), Window Input Name, Window Visible, Window Hidden, and Window Shows Input 1-4.
- Main Window and Full Screen - Main Window Input, Main Window Input Name, Main Window Is Input 1-4, Full Screen Input 1-4.
- Inputs - Input Name, Input Signal, Input No Signal, Input Cable Connected, Input EDID, for each input.
- Audio - Audio Source (number), Audio Source Name, Audio Muted, Audio Follows A Window, and one Audio Is ... boolean per source.
- Presets - Last Preset Applied, and Preset Saved / Preset Active for each of the 8 presets.
- Loop Outputs - the input on each loop output.
- Licence - License State (0 Unlicensed, 1 Trial, 2 Licensed), License Status, License Licensed, License Trial, License Unlicensed, License Trial Remaining, MAC For Key and related trial values.
Events
Connected, Disconnected, Command Rejected By MV41, Power On, Power Off, Layout Changed, Main Window Input Changed, Audio Source Changed, Display Connected, Display Disconnected, Preset Applied, Signal Found and Signal Lost for each input, Trial Ending Soon, Trial Expired.
Events fire on real changes only. The first status read after the driver starts or reconnects is silent, so a processor reboot never fires your macros for something that did not change.
Autoprogramming Support
Drop a tag on a button and both the command and its feedback are wired:
- Power On, Power Off, Power, Output On, Output Off
- Full Screen Input 1 to Full Screen Input 4
- Layout Single (full screen), Layout Side by Side, Layout Top and Bottom, Layout PIP Top Left, Layout PIP Bottom Left, Layout PIP Top Right, Layout PIP Bottom Right, Layout Triple Left, Layout Triple Right, Layout Triple Top, Layout Triple Bottom, Layout Quad Square, Layout Quad Large Left, Layout Quad Large Right, Layout Quad Large Top, Layout Quad Large Bottom
- Multiview Layout, Layout Next, Layout Previous
- Window N Input M (N and M are 1 to 4)
- Main Window Input 1 to Main Window Input 4
- Audio Mute, Audio Input 1 to 4, Audio Window 1 to 4, Audio Mute Toggle
- Preset 1 to Preset 8, Refresh
Text tags: Layout Name, Window N Name, Main Window Name, Input N Name, Audio Source, Output Resolution, Connection Status, Last Error.
Show / hide tags (bind to a layer or a button's Visible slot): Single View, Multiview, Window N Visible, Window N Hidden, Input N Signal, Input N No Signal, Display Connected, Display Not Connected, Disconnected, Preset N Saved.
Run Print Tag Reference to list the tags and input names in the log.
Limitations
- Changes made on the MV41's web page, front panel or IR remote are not announced by the MV41. The driver sees them at the next status read.
- Seamless switching and auto switching cannot be read back from the MV41, so there is no feedback for them.
- The custom (user defined) layout can be shown and its windows routed, but it can only be designed in the MV41's web page.
- Audio from a window follows that window even when the window is hidden in the current layout. Use Audio Window 1 for audio that always follows the main picture.
- Set Input EDID needs the MV41's EDID DIP switches set to 1111.
- Network settings, reset and reboot are not available from the driver. Use the MV41's web page.
Support Contact
Smart Home Programming and Automation
- Email: david@smarthomeprogramming.com.au
- Phone: 0401 190 122
- Web: https://smarthomeprogramming.com.au
Licensed per RTI processor. The key is generated from the processor MAC address, and one key covers the MV41 driven from that processor.
A 120-minute trial runs without a key. When the trial expires, control commands stop until a valid key is entered - feedback and status keep running.