Driver Details

New Community

Hisense_DM/GM50D

By: Daniel Richer
Updated: July 1, 2026
Version: 1.5
Download Driver
Rating: 0.0 (0 ratings)
Log in to rate this driver

Driver Information

Control for DM and GM50D series of Hisense Commercial displays.
Power On will require Wake On LAN (WOL) which will require the TV to be connected to the network via hardwired ethernet cable.
All other commands will work via direct IP commands.

Supported Devices

DM66D series
GM50D series

Limitations

Only 1 network connection is allowed to the Hisense displays – this is a Hisense limitation.
Hardwired ethernet connection needed if requiring to power display on via IP control.
After TV is powered on there may be a small time delay before TV allows for IP control – have tried to reduce this as much as possible but seems display takes some time to respond after being powered on.

Display Configuration

To gain access to the IP control side please configure the display to allow this.
1. Launch the IP Control App ---- Home > All Apps > IP Control
2. Set the port number – default is port 8000, if this is occupied choose a port between 5000 – 12000 (will need to stop services to alter and restart once changes made)

Nothing needed for RS232 control - however please note pin outs for the display are as follows
3 = Ground
5 = RX
8 = TX

Device Configuration

Name – Name of TV (can leave as the default – Hisense)
For IP control you have
IP Address – IP address of the display
Port number - as you have set in the TV
MAC Address – MAC address required for WOL

Tech Support is handled by Habitech Ltd

Please have the subject of the email titled - RTI Driver - <driver name>
For example, RTI Driver - Hisense to RTI@Habitech.co.uk

Hisense - DM/GM50D series TV Driver

Hisense DM/GM50D series IP driver only

Introduction & Manufacturer Profile

Hisense is a global manufacturer of display and consumer electronics technology, with a strong presence in professional and commercial AV markets. The company designs and produces a wide range of displays used in corporate, education, retail, and hospitality installations.
The DM and GM series are specifically targeted at commercial installations.

Version History

Version 1.0
Initial release

Version 1.1
Added RS232 options for control

Version 1.5 - April 28, 2026
Audit pass: stdmessage() now gated behind Debug toggle so production deployments stay quiet in TraceViewer. RS232 poll timer no longer dies after first fire (now self-arms each cycle). DeviceDescription template corrected from invalid "TV" to "Cable/Satellite TV" (autoprogramming compatibility).

Driver Information

Control for DM and GM50D series of Hisense Commercial displays.
Power On will require Wake On LAN (WOL) which will require the TV to be connected to the network via hardwired ethernet cable.
All other commands will work via direct IP commands.

Supported Devices

DM66D series
GM50D series

Limitations

Only 1 network connection is allowed to the Hisense displays – this is a Hisense limitation.
Hardwired ethernet connection needed if requiring to power display on via IP control.
After TV is powered on there may be a small time delay before TV allows for IP control – have tried to reduce this as much as possible but seems display takes some time to respond after being powered on.

Display Configuration

To gain access to the IP control side please configure the display to allow this.
1. Launch the IP Control App ---- Home > All Apps > IP Control
2. Set the port number – default is port 8000, if this is occupied choose a port between 5000 – 12000 (will need to stop services to alter and restart once changes made)

Nothing needed for RS232 control - however please note pin outs for the display are as follows
3 = Ground
5 = RX
8 = TX

Device Configuration

Name – Name of TV (can leave as the default – Hisense)
For IP control you have
IP Address – IP address of the display
Port number - as you have set in the TV
MAC Address – MAC address required for WOL

Driver commands

Commands supported in the driver.

Power Commands
Power On, Off and Reboot
Display On and Display Off

Input Commands
HDMI 1 , HDMI 2, VGA, Display Port, PC, DVI

Volume Commands
Mute On, Off and Toggle
Volume Up, Down and set volume

Cursor controls
Up, Down, Left, Right and OK

Remote Keys
Menu, Return, Source, Settings and Home

Miscellaneous
Open CMS, Screencast, Turn On Hotspot and Take Screenshot

Freezescreen
On and Off

System Requirements & Prerequisites

RTI Integration Designer 11.5 or later.
XP Processor Firmware 23.5.11 or later.
Aten PDU firmware with Telnet server enabled.
Static IP assignment or DHCP reservation recommended for reliability.

Tech Support is handled by Habitech Ltd

Please have the subject of the email titled - RTI Driver - <driver name>
For example, RTI Driver - Hisense to RTI@Habitech.co.uk